FUJI错误代码查询.pdf - 第1131页
Code: 15040344 Display: Main-conveyor Panel conveyance Error Used by: CP-752E Cause: While waiting for the next panel, either the XY-table panel speed reduction sensor (X0AE) or the XY-table panel arrival sensor (X0AF) d…
------------------------------
Code: 1504033E
Display: Middle loading sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table loading height sensor (X05C) is not operating properly. This sensor fails to switch
on when the Z-axis is at the middle loading position. Alternatively, this sensor switches on when the Z-
axis is not at the middle loading position +/-500 pulses.
Remedy: Adjust the mounting position of the XY-table loading height sensor (X05C).
------------------------------
Code: 1504033F
Display: Panel check error
Used by: CP-732E, CP-742ME, CP-742E
Cause: The sensor check results differ from the machine's current status memory.
Remedy: Adjust the position of the sensor as required so that the panel on the main conveyor is correctly
detected.
------------------------------
Code: 15040340
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: A panel was loaded onto the main-conveyor, however, the panel was not detected (ON) at either
the XY-table panel speed
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properly a
nd confirm the panel status.
------------------------------
Code: 15040341
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The panel passed through the XY-table panel speed reduction sensor, however, it was not
detected at the panel arrival c
heck sensor (X0AF) within the specified time limit.
Remedy: Check that the panel arrival check sensor is functioning properly and confirm the panel status.
------------------------------
Code: 15040342
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to unload the board from the main-conveyor however, the XY-table panel
speed reduction sensor (X0AE
) or the panel arrival check sensor (X0AF) did not deactivate (OFF) within the specified time limit.
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040343
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to transfer a panel from the main-conveyor, however, the out-conveyor
unload panel sensor (X0CB) di
d not activate (ON) within the specified time.
Remedy: Check that the out-conveyor panel arrival sensor is functioning properly and confirm the panel
status.
------------------------------
第 1130 页
Code: 15040344
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: While waiting for the next panel, either the XY-table panel speed reduction sensor (X0AE) or the
XY-table panel arrival
sensor (X0AF) detected a panel.
While waiting for a signal from the next machine, either the XY-table panel speed reduction sensor, (X0AE)
and the panel arrival
check sensor (X0AF) was deactivated (OFF).
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040345
Display: Main-conveyor panel loading error
Used by: CP-752E
Cause: When a panel is detected on the conveyor, the conveyor loads the panel.
If a panel is not detected on the conveyor the conveyor attempts to unload the panel.
Remedy: Check that the XY-table panel speed reduction and panel arrival sensors are functioning
properly.
------------------------------
Code: 15040346
Display: Main-conveyor Stopper Error
Used by: CP-752E
Cause: One of the following errors has occurred:
The machine output the "lower stopper" signal, however the XY-table stopper lower end sensor (X0AA) did
not activate (ON).
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
activate (ON) within the spe
cified time limit.
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
deactivate (OFF) within the
specified time limit.
Remedy: Check that the stopper is functioning properly, if the error continues. Check that both of the
sensors带幨X0AA, X0A9带幩ar
e functioning properly.
------------------------------
Code: 15040347
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The XY-table panel arrival sensor (X0AF) was activated before the XY-table panel speed reduction
sensor (X0AE).
Remedy: Check that the main-conveyor panel speed reduction sensor is functioning properly and confirm
the panel status.
------------------------------
Code: 15040348
Display: Panel Set Error
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is not the pallet on the XY-table in the position indicated.
Remedy: Lower the Z-axis to its lower limit position and then clear the in-carrier clamper related error.
Set the pallet on the XY-table in the position indicated.
第 1131 页
------------------------------
Code: 15040349
Display: Panel Set Error
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is not the pallet on the XY-table in the position indicated.
Remedy: Lower the Z-axis to its lower limit position and then clear the out-carrier clamper related error.
Set the pallet on the XY-table in the position indicated.
------------------------------
Code: 1504034A
Display: 电路板位置异常
Used by: GPX
Cause: 在载入侧搬运轨道无法搬运的位置上有电路板。
Remedy: 请除去电路板然后重新放入。
<img src="$LKEY_ERRIMG_MC$/EI0002.bmp">
------------------------------
Code: 1504034B
Display: 主搬运轨道有电路板错误
Used by: NXTP,GPX-C
Cause: 因为在主搬运轨道上有电路板,所以不进入到下一步的处理。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/1504034B.PNG">
------------------------------
Code: 1504034C
Display: 由于主搬运轨上存在电路板,所以读取电路板支撑块的二维码时出现错误。
Used by: NXTP, GPX-C
Cause: 由于主搬运轨上存在电路板,所以无法读取电路板支撑块的二维码。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/1504034B.PNG">
------------------------------
Code: 15040401
Display: OUT CVYOR INTERLOCK
Used by: IP1,NP132,NP133
Cause: The board on the main conveyor is protruding onto the out-conveyor. Or the board which is on
the out-conveyor is protruding into the pallet unloader .
Remedy: Check the board on the out-conveyor. Adjust the main conveyor board arrival sensor and the
out-conveyor board pass sensor. Check the X034: OUT_PASS_CHK (out-conveyor board pass check)
signal at the I/O map.
------------------------------
Code: 15040402
Display: 周期异常 送出错误 (IP1,IP2) 送出异常(GSP,GL)
电路板送出异常(NP2,QP3)
Used by: GL2,GSP2,GSP3,IP1,IP2,NP2,QP3,GPX,NXTP
Cause: 在从主搬运轨道上排出电路板中,发生了电路板被卡住等的异常。主搬运轨道在排出电路板后,在预定时间
内没有到达下工序。或者,主搬运轨道的电路板确认传感器一直为ON。
在从通过确认点到下工序的之间发生了电路板送出超时。(NP2,QP3) 在主搬运轨道排出电路板之后的预定时间
内,电路板没有到达送出搬运轨道。 (GPX)
Remedy: 请确认从主搬运轨道上送出的电路板。可认为电路板偏离正常的位置,请除去被认为发生异常的电路板。
请保证电路板能够顺畅地送出到下工序。(NP2,QP3) 1.请确认搬运轨道上电路板是否被卡住了。
2.可认为电路板偏离了正常位置,请除去被认为发生了异常的电路板。
3.请确认搬运轨道间的电路板取入是否能顺畅地进行。
3-1.搬运轨道宽度的再调整