FUJI错误代码查询.pdf - 第79页
Used by: GPX-C Cause: 印刷位置的设置允许范围会受其它参数(丝网尺寸、锡膏卷直径)的影响而变动。如果其他参数值太大,则 印刷范围就无法合理设置。 Remedy: 请调小Mesh Size或Roll Width。 ------------------------------ Code: 1101C50? Display: 1101C50? Used by: GSP5,GP2,GP3,GP551,GP6 Cause: ?…
·第10个sequence:电路板尺寸Y。
------------------------------
Code: 1101C402
Display: 印刷顺序的印刷位置指定错误
Used by: NXTP
Cause: Flexa上印刷顺序的设定值超过公差值。
Remedy: ·请指定起点和终点。
·一侧最大可以指定10个顺序。
·请设定次顺序的值大于前顺序的值。
·位置的最小值和最大值在范围外(虽然印刷范围受其他参数的影响为可变数值,但是0~电路板尺寸为止为可印刷范围)
------------------------------
Code: 1101C403
Display: 印刷顺序的印刷位置指定错误
Used by: NXTP
Cause: Flexa上的印刷顺序的两侧印刷的指定方法超出公差值。
Remedy: ·请在Front侧和Rear侧上设定相同数量的印刷位置。
·请在Front侧和Rear侧上设定相同位置的印刷位置。
------------------------------
Code: 1101C404
Display: 印刷sequence的印刷范围延伸设置错误
Used by: GPX
Cause: 印刷sequence的印刷范围延伸设置不正确。
Remedy: 请确认生产程序中的印刷sequence。
如果第1个sequence的起点在电路板外围,
则请将第二个sequence的起点设置为0.00mm。
如果最后一个sequence需要印刷电路板外围,
则最后第2个sequence的数值与电路板尺寸Y必须保持一致。
------------------------------
Code: 1101C405
Display: 印刷sequence的数量设置错误
Used by: GPX
Cause: 印刷sequence的数量未设置或超出规定范围。
Remedy: 单侧最多可设置10个sequence。如果按印刷方向进行设置,则Front和Rear的数量和位置都必须相同。
------------------------------
Code: 1101C406
Display: 印刷sequence的数量设置错误
Used by: GPX-C
Cause: 在Flexa中设置的印刷sequence(Print Solder)有误。
Remedy: (Fig.1)如果印刷sequence不设置任何数值,则可以以默认值进行印刷。(Fig.2)如果设置印刷sequence,则
请设置2个点(起点和终点)。(Fig.3)如果按印刷方向设置印刷sequence,则请设置4个点(起点和终点×2)在这种情形下
,请将起点和终点位置设置为相同数值。(Fig.4)设置时数值可以超出电路板尺寸。(以电路板尺寸Y=150mm为例)
<img src="$LKEY_ERRIMG_MC$/1101C406.jpg">
------------------------------
Code: 1101C407
Display: 「印刷sequence」项目中的印刷位置设置错误
Used by: GPX
Cause: 代表位置的最小值、最大值超出规定范围。
Remedy: 代表印刷允许范围的数值会受其它参数的影响而变动。
------------------------------
Code: 1101C408
Display: 「印刷sequence」项目中的印刷位置设置错误
第 78 页
Used by: GPX-C
Cause: 印刷位置的设置允许范围会受其它参数(丝网尺寸、锡膏卷直径)的影响而变动。如果其他参数值太大,则
印刷范围就无法合理设置。
Remedy: 请调小Mesh Size或Roll Width。
------------------------------
Code: 1101C50?
Display: 1101C50?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The specified X (Z) value
exceeds the range.
Remedy: The input range for X (Z) is from -1 to -500 (-0.01mm to -5.00mm). Correct and then retransmit
the data.
------------------------------
Code: 1101C51?
Display: 1101C51?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The specified Y (SPEED)
value exceeds the range.
Remedy: The input range for Y (SPEED) is from 0 to 8,000 (0.00mm/sec to 80.00mm/sec). Correct and
then retransmit the data.
------------------------------
Code: 1101C52?
Display: 1101C52?
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: ? represents a Z sequence number, where the first Z sequence is "1". The X (Z) value is logically
wrong.
Remedy: Ensure that data values become smaller in sequential order.
------------------------------
Code: 1101C53?
Display: Same as code
Used by: GP551,GP6
Cause: The movement range for a cleaning sequence has been exceeded. The value replacing the "?" in
the code is the number of the problematic cleaning sequence, when the number of the first
cleaningsequence is 1.
Remedy: Check the Proper data and production program data values. The cleaning sequence range for a
double-side cleaner is found by subtracting "org_pos_clnr" (the cleaner's program origin) from both
"max_limit_pos_s_clnr" and "min_limit_pos_s_clnr", and converting the results to units of 1/100 mm. The
cleaning sequence range for a single-side cleaner is found by subtracting "org_pos_clnr" (thecleaner's
program origin) from both "max_limit_pos_y_clnr" and "min_limit_pos_y_clnr", and converting the res lts to
units of 1/100 mm.
------------------------------
Code: 1101C54?
Display: Same as code
Used by: GP551,GP6
Cause: The speed range for a cleaning sequence has been exceeded. The value replacing the "?" in the
code is the number of the problematic cleaning sequence, when the number of the first cleaning sequence
is 1.
Remedy: Correct the data and retransmit the program. The speed range for cleaning sequences is from 1
to 14500 [1/100 mm/second]. The -1 indicating the final cleaning sequence is not checked.
------------------------------
Code: 1101C55?
第 79 页
Display: Same as code
Used by: GP551,GP6
Cause: There is a logical error in a cleaning sequence. The value replacing the "?" in the code is the
number of the problematic cleaning sequence, when the number of the first cleaning sequence is 1.
Remedy: Make sure that the number of the specified cleaning sequence is decreasing in sequence number
order.
------------------------------
Code: 1101C56?
Display: Same as code.
Used by: GP6
Cause: The "?" represents the printing sequence number when the first printing sequence is 1. This is a
printing sequence logic error.
Remedy: Check that the set printing sequence is not gradually decreasing in value.
------------------------------
Code: 1101C6??
Display: same as code (1101C600 + (I-1) / 20,where I is the sequence number).
Used by: CP643
Cause: The second board has a block number that is lower than the first board
maximum block number.
Remedy: Check the block numbers in the sequences indicated by the error message,as well as the first
board's maximum block number.
------------------------------
Code: 1101C700
Display: 同一个供料平台No./料站No.所设定的顺序数据中、同时存在0 和1 的供料器跳过设定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 因为在同一供料平台No./料站No.所设定的顺序数据中,同时存在设定供料器跳过和未设定为供料器跳过
,所以不能正常运转。
Remedy: 请将同一供料平台No./料站No.所设定的顺序数据的供料器跳过全部修正为相同的设定。
------------------------------
Code: 1101C701
Display: 不是joint模式时、不能在顺序数据中进行供料平台2的设定。
Used by: XP141,XP142
Cause: 不是joint模式时、不能在顺序数据中进行供料平台2的设定。
Remedy: 请将供料平台No.设定为2的顺序数据全部跳过或删除。
------------------------------
Code: 1101C702
Display: 没有种类为 'D' 的顺序数据。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 顺序数据中没有贴装顺序(种类为‘D’)。
Remedy: [机上编辑] 在没有贴装顺序进行运转时,请将电路板数据的通过模式设定为「1:Pass」。
[Fuji Flexa] 在没有贴装顺序进行运转时,请将Pass Mode设定为「On」或者は「Auto」。
------------------------------
Code: 1101C703
Display: X坐标超过电路板的范围。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 显示出顺序数据的X坐标在电路板尺寸以外。
Remedy: 请将X坐标设定在电路板尺寸以内。
------------------------------
Code: 1101C704
Display: Y坐标超过电路板的范围。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
第 80 页