FUJI错误代码查询.pdf - 第733页
Placing pressure calculation could not be carried out because pressure offset of relevant nozzle was not executed or Proper data was incorrect.(QP3) Remedy: Perform placing pressure calibration for the nozzle to be used,…
"Not an SRM type memory card"
Used by: QP203
Cause: The SRM was started with an incompatible memory card.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use an SRM memory card to start the machine.
------------------------------
Code: 12070?64
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command was Ignored" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A command was ignored for some reason.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?66
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PPC data out of range" (QP2)
placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: The placing pressure set in the Part data is outside the valid placing pressure range for the
specified nozzle.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Place-Pressure is not set in part data or is out of range.(QP3-DM)
The [Placing]-[Pressure] value in part data exceeds the pressure control range for the nozzle
selected.(QP3-MM)
Remedy: Check the placing pressure set in the Part data and the specified nozzle. Check the Proper data
values that set for the placing pressure for the specified nozzle.(QP2)
Set Place-Pressure in part data.(QP3-DM)
Set the [Placing]-[Pressure] value within the range of the specified nozzle or change to a nozzle suitable
for the value.(QP3-MM)
------------------------------
Code: 12070?67
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Nozzle name in PD" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: A nozzle name has not been set in the Part data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: To execute placing pressure control, set the name of the nozzle to be used in the Part data.
------------------------------
Code: 12070?68
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Proper data for PPC" (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: The Proper data for the nozzle to be used does not include parameters related to placing pressure
control.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
第 732 页
Placing pressure calculation could not be carried out because pressure offset of relevant nozzle was not
executed or Proper data was incorrect.(QP3)
Remedy: Perform placing pressure calibration for the nozzle to be used, and measure the necessary
Proper data values.(QP2)
Carry out regular placing pressure offset of relevant nozzle.(QP3)
------------------------------
Code: 12070?69
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PPC calibration pos." (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: A placing pressure control calibration position has not been set in the Proper data.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Regular placing pressure zero adjustment not carried out since placing pressure offset position
measurement has not been executed.(QP3)
Remedy: Use the [MEASURE PROPER] command to measure the placing pressure calibration
position.(QP2)
Carry out placing pressure offset position measurement.(QP3)
------------------------------
Code: 12070?6A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Remover up/down timeout" (QP2)
Used by: QP242
Cause: A timeout has occurred while raising or lowering the remover.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that nothing is interfering with the remover. Use I/O commands to make sure that
the remover moves smoothly, and that the upper limit and lower limit sensors are functioning normally.
------------------------------
Code: 12070?6B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Linearity Tolerance Error" (QP2)
Used by: QP242
Cause: A linearity tolerance error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Replace the part that caused the error or increase the "linear_tolerance" item value in part data.
------------------------------
Code: 12070?6C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Lead Quantity Error" (QP2)
Used by: QP242
Cause: A lead quantity error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Replace the part that caused the error or check that the number of leads on the part matches
with the number of leads recorded in part data.
------------------------------
Code: 12070?6D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Coplanarity Tolerance Error" (QP2)
Used by: QP242
Cause: A coplanarity tolerance error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
第 733 页
Remedy: Replace the part that caused the error or increase the "copla_tolerance" item value in part data.
------------------------------
Code: 12070?6E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Within LLL sensor range" (QP2)
Used by: QP242
Cause: Within LLL sensor range.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Increase the value of the part data item, "lead_offset" where the error occured. Alternatively,
change the currently used nozzle to one of smaller diameter.
------------------------------
Code: 12070?6F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan_area too large" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is too large.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the part does not exceed the maximum size that can be handled by the vision
processing system. If the scan area is set in part data, check that value.
------------------------------
Code: 12070?70
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan area is not set" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is not set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error does not normally occur.
------------------------------
Code: 12070?71
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Orientation Check Error Check the orientation of the tray" (QP2)
Used by: QP201,QP202
Cause: This is an orientation error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Correct the orientation of the tray and rearrange the packages so that starting from the upper
left hand corner moving downward, the packages fill the tray leaving the bottom right hand corner empty.
------------------------------
Code: 12070?72
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Dummy Parts" (QP2)
Used by: QP201,QP202
Cause: These are dummy parts.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: No remedy is required.
------------------------------
Code: 12070?75
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Tray / Tray Unit Full" (QP2)
Used by: QP201
Cause: (APL) There are no supply trays or, the unloading elevator is full.
(value replacing "?" is module number; error code appears in place of asterisks)
第 734 页