FUJI错误代码查询.pdf - 第435页

Code: 12035306 Display: Used by: CP6,CP6M,CP65,GP551,GP6,NP132,NP133,QP132 Cause: Axis number 3 - soft limit. Remedy: Turn off the machine power. ------------------------------ Code: 12035307 Display: Used by: CP5,CP6,CP…

100%1 / 5282
Cause: Incorrect parameter was sent from axis number 2.
Remedy: Turn off the machine power.
------------------------------
Code: 1203520A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132,NP133E,NP134E,NP153E
Cause: Axis number 2 encoder error.
Remedy: Turn off the machine power.
------------------------------
Code: 1203520B
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 2 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 1203520C
Display:
Used by: CP6,CP6M,CP65,GP551,GP6
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
Code: 12035301
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 3 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035302
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 3 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035303
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 3 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035304
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 3 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035305
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 3 + soft limit.
Remedy: Turn off the machine power.
------------------------------
第 434 页
Code: 12035306
Display:
Used by: CP6,CP6M,CP65,GP551,GP6,NP132,NP133,QP132
Cause: Axis number 3 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035307
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 3 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035308
Display:
Used by: CP5,CP6,CP6M,CP65,QP132
Cause: Axis number 3 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035309
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Incorrect parameter was sent from axis number 3.
Remedy: Turn off the machine power.
------------------------------
Code: 1203530A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132,NP133E,NP134E,NP153E
Cause: Axis number 3 encoder error.
Remedy: Turn off the machine power.
------------------------------
Code: 1203530B
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 3 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 1203530C
Display:
Used by: CP6,CP6M,CP65,GP551,GP6
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
Code: 12035401
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 4 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035402
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
第 435 页
Cause: Axis number 4 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035403
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035404
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035405
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 + soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035406
Display:
Used by: CP6,CP6M,CP65,GP551,GP6,NP132,NP133,QP132
Cause: Axis number 4 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035407
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 4 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035408
Display:
Used by: CP5,CP6,CP6M,CP65,QP132
Cause: Axis number 4 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035409
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Incorrect parameter was sent from axis number 4.
Remedy: Turn off the machine power.
------------------------------
Code: 1203540A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132,NP133E,NP134E,NP153E
Cause: Axis number 4 encoder error.
Remedy: Turn off the machine power.
------------------------------