FUJI错误代码查询.pdf - 第2198页

program. The "GSQST" value must be one of "D", "F", "B", "G", "M", "T" or "Z". Normally the sequence number in which the error occurred is r…

100%1 / 5282
Cause: A format error was detected in the item"SOLDER_NUM"under"BLOCK","HEADER-" when "UNIT",
"PROGRAM" of the specified production program was read.
Remedy: Check the setting for item"SOLDER_NUM"under"BLOCK","HEADER-"of"UNIT","PROGRAM".
------------------------------
Code: 51??1027
Display: "SOLCO_NUM"format error under "BLOCK","HEADER-"of"UNIT","PROGRAM".
Used by:
Cause: A format error was detected in the item"SOLCO_NUM"under"BLOCK","HEADER-" when "UNIT",
"PROGRAM" of the specified production program was read.
Remedy: Check the setting for item"SOLCO_NUM"under"BLOCK","HEADER-"of"UNIT","PROGRAM".
------------------------------
Code: 51??1030
Display: "GSMSQQ" entry is incorrect.
Used by:
Cause: An out of range value was detected in "GSMSQQ" in the "BLOCK", "PGHEAD-" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the value for "GSMSQQ" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD-" in the production
program.
------------------------------
Code: 51??1040
Display: No item definition for "GSQSN".
Used by:
Cause: No description was found for "GSQSN" in the item definition line in "BLOCK", "SEQUENCE+"
when "UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the "GSQSN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"SEQUENCE+" in the production program. "GSQSN" is a mandatory item.
------------------------------
Code: 51??1041
Display: No "GSQST" item definition.
Used by:
Cause: No "GSQST" description was found in the item definition line in "BLOCK", "SEQUENCE+" when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the "GSQST" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"SEQUENCE+" in the production program. "GSQST" is a mandatory item.
------------------------------
Code: 51??1042
Display: Compatible sequence data was not found.
Used by:
Cause: Data with the necessary sequence numbers was not found in the "BLOCK", "SEQUENCE+" data
when "UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Normally the sequence number in which the error occurred is reported to the supplementary
information line. Check this line. Furthermore check the value for "GSMSQQ" in "UNIT", "PROGRAM" -
"BLOCK", "PGHEAD-".
------------------------------
Code: 51??1043
Display: "GSQST" value out of range.
Used by:
Cause: An out of range value was detected for "GSQST" in the "BLOCK", "SEQUENCE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
第 2197 页
program. The "GSQST" value must be one of "D", "F", "B", "G", "M", "T" or "Z". Normally the sequence
number in which the error occurred is reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1044
Display: "GSQSTN" value out of range.
Used by:
Cause: An out of range value was detected for "GSQSTN" in the "BLOCK", "SEQUENCE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Normally the sequence number in which the error occurred is reported to the supplementary
information line. Check this line.
------------------------------
Code: 51??1045
Display: "GSQSLTN" value out of range.
Used by:
Cause: An out of range value was detected for "GSQSLTN" in the "BLOCK", "SEQUENCE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Normally the sequence number in which the error occurred is reported to the supplementary
information line. Check this line.
------------------------------
Code: 51??1046
Display: "GSQDN" value out of range.
Used by:
Cause: An out of range value was detected for "GSQDN" in the "BLOCK", "SEQUENCE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Normally the sequence number in which the error occurred is reported to the supplementary
information line. Check this line.
------------------------------
Code: 51??1047
Display: Incorrect reference to device data.
Used by:
Cause: When the data in "BLOCK", "SEQUENCE+" in "UNIT", "PROGRAM" in the specified production
program was read, an error occurred because the device data setting was not correctly made even though
the device data at "GSQST" was referred to.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the production
program. Normally the sequence number in which the error occurred is reported to the supplementary
information line. Check this line.
------------------------------
Code: 51??1048
Display: "GSQST" not used with this machine type.
Used by:
Cause: "UNIT", "PROGRAM" in the specified production program was read but the "GSQST" value in
"BLOCK", "SEQUENCE+" is not used with this machine type.
Remedy: Check the data setting for "GSQST" in "UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+" in the
production program. Normally the sequence number in which the error occurred is reported to the
supplementary information line. Check this line.
------------------------------
Code: 51??1050
Display: No "GUTSTN" item definition.
第 2198 页
Used by:
Cause: No "GUTSTN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTSTN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTSTN" is a mandatory item.
------------------------------
Code: 51??1051
Display: No "GUTSLTN" item definition.
Used by:
Cause: No "GUTSLTN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTSLTN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTSLTN" is a mandatory item.
------------------------------
Code: 51??1052
Display: No "GUTDN" item definition.
Used by:
Cause: No "GUTDN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTDN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTDN" is a mandatory item.
------------------------------
Code: 51??1053
Display: No "GUTPDN" item definition.
Used by:
Cause: No "GUTPDN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTPDN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTPDN" is a mandatory item.
------------------------------
Code: 51??1054
Display: No compatible device data was found.
Used by:
Cause: Data for the necessary station numbers, slot numbers and device numbers was not found in the
"BLOCK", "SEQUENCE+" data when "UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Normally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line. Also check the device data references in
"UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+".
------------------------------
Code: 51??1055
Display: "GUTSTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTSTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1056
Display: "GUTSLTN" value out of range.
Used by:
第 2199 页