malfunctions of the communication board or the RB controller. ------------------------------ Code: 1207F?02 Display: "SCU?(ICM,PMC?) Error Code:********" "RB Servo Error During Axis Movement" Used by:…
carrier. Care should be taken as the parts may become dislodged.
------------------------------
Code: 1207E?6F
Display: "SCU? (PMC?, ICM) Error Code:********"
"Pocket unclamping error"
Used by: QP201
Cause: The FOL carrier pocket clamps were not released within the required time.(The question marks
represent the module number, and the asterisks represent the error code.)
Remedy: Check the action of the pocket clamps.
------------------------------
Code: 1207E?70
Display: "SCU? (PMC?, ICM) Error Code:********"
"Packages on carrier"
Used by: QP201
Cause: Packages ware detected on the carrier during conveyance.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Check whether there are packages on the carrier.
------------------------------
Code: 1207E?71
Display: "SCU? (PMC?, ICM) Error Code:********"
"Part supply direction error"
Used by: QP203
Cause: The supply direction of the heat spreader parts on the coin stack feeder may be incorrect.(The
question marks represent the module number, and the asterisks represent the error code.)
Remedy: Check the direction of the spreader parts on the coin stack feeder.
------------------------------
Code: 1207E?72
Display: "SCU? (PMC?, ICM) Error Code:********"
"Feeder interference area"
Used by: QP203
Cause: The head is inside the coin stack feeder interference area.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Move the head outside the coin stack feeder interference area.
------------------------------
Code: 1207F?00
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Controller Error"
Used by: QP242
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 1207F?01
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
第 834 页
malfunctions of the communication board or the RB controller.
------------------------------
Code: 1207F?02
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error During Axis Movement"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?03
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Protocol Error"
Used by: QP242
Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data.
The RB unit ALM light is on.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation. It is possible that the cable, communication board, or
RB controller is faulty.
------------------------------
Code: 1207F?04
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Disconnected Axis"
Used by: QP242
Cause: The specified axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?05
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit. The ALM lamp on the RB unit
will light when this error occurs. (If the new RB unit is being used, an amp driver alarm will be indicated.)
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. (If the new RB unit is being used, check the amp driver power
supply.)
------------------------------
Code: 1207F?06
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Controller Processing"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
第 835 页
Code: 1207F?07
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Transmission Timeout"
Used by: QP242
Cause: The command's first character was not input within the specified time (30 ms).
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?08
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Transmission Timeout"
Used by: QP242
Cause: The time between characters exceeds 100 ms.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?09
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?0A
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Axis Alarm Still Occuring"
Used by: QP242
Cause: A command was received before the machine was reset.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?0B
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?0C
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Driver Error"
Used by: QP242
Cause: An alarm is occurring from the RB servo's driver. This error does not usually occur.
"?" indicates the module number (QP2).