FUJI错误代码查询.pdf - 第587页
Cause: A cleaner interlock occurred when the cleaner drive axis (the Y-axis for a double-side cleaner, or the S-axis for a single-side cleaner) was activated. This error occurs if the cleaner drive axis is activated whil…
CHK shows a value of 0).
------------------------------
Code: 1205610F
Display: Interlock (Z|Y) Conveyor Width Clutch
Used by: GP551,GP6
Cause: The displayed axis and the conveyor width clutch may collide.This error occurs when the
conveyor width clutch is engaged while the displayed axis is in motion.
Remedy: Disengage the conveyor width clutch. Alternatively, check the on/off status of the conveyor
width clutch's engaged/disengaged sensors.
------------------------------
Code: 12056110
Display: 联锁 Z轴 相机
[Interlock Zaxis Camera]
Used by: GP551,GP6,GPX,NXTP
Cause: Z轴与相机有可能发生了干涉。在Z轴移动时相机不在待机位置的情况下发生。
Remedy: 请将相机移动到待机位置。或者,请确认相机的待机位置确认传感器的ON/OFF动作。
<img src="$LKEY_ERRIMG_MC$/12056110.PNG">
------------------------------
Code: 12056111
Display: Interlock Z axis Cleaner
Used by: GP551,GP6
Cause: The Z-axis and the lower cleaner may collide.This error occurs when the lower cleaner is not at its
origin position and the Z-axis is in motion. On the GP-6, this error occurs when the cleaner shift is not at
its retract position while the Z-axis is in motion.
Remedy: Move the lower cleaner to its origin position. On the GP-6, for one-sided cleaners, move the
cleaner shift to it retract position. Alternatively, check the on/off status of the sensors at the cleaner
origin position and, on the GP-6, the cleaner shift retract position.
------------------------------
Code: 12056112
Display: Interlock SSD axis Cylinder
Used by: GP551,GP6
Cause: The solder supply syringe which is joined to the SSD-axis may collide with another part. This
error occurs when the solder supply syringe is down and an attempt is made to move the SSD-axis.
Remedy: Raise the solder supply syringe. Alternatively, check the on/off status of the up/down sensors
on the syringe.
------------------------------
Code: 12056113
Display: "Please Camera escape"
Used by: GP551,GP6
Cause: The camera (X-axis) and the Z-axis are in an interference zone with respect to each other, or are
interfering with each other. This error occurs if the holder is changed while neither the camera (X-axis) nor
the Z-axis are at their respective escape positions.
Remedy: Move the Z-axis to the Z-axis escape position (the position at which X03C:Z ESC POS CHK
shows a value of 0), or move the camera (X-axis) to its escape position (the position at which X03D:X ESC
POS CHK shows a value of 0). If necessary, make sure that the Z-axis/camera interference prevention
interlock sensor and the X-axis camera escape position check sensor (X03C:Z ESC POS CHK and X03D:X
ESC POS CHK) are functioning normally.
------------------------------
Code: 12056114
Display: "Cleaner Is Engaged"
Used by: GP6
第 586 页
Cause: A cleaner interlock occurred when the cleaner drive axis (the Y-axis for a double-side cleaner, or
the S-axis for a single-side cleaner) was activated. This error occurs if the cleaner drive axis is activated
while the cleaner is connected to the drive axis during command execution or automatic operation.
Remedy: Use [HEAD REMOVAL] on command page 553-2(3) to disconnect the cleaner from the drive axis
(the Y-axis for a double-side cleaner, or the S-axis for a single-side cleaner). If necessary, make sure that
the lower cleaner connection check sensor and the cleaner connection position proximity check sensor
(X05D:LW CLR CPL CHK and X03E:CLNR NEAR CHK) are functioning normally.
------------------------------
Code: 12056115
Display: "Solder Unit Off Origin"
Used by: GP551,GP6
Cause: A solder supply unit interlock occurred when the S-axis was activated. This error occurs if the S-
axis is activated while the solder supply unit is not at the origin position during command execution or
automatic operation.
Remedy: Use [ESCAPE POSITION MOVEMENT] on command page 544(4) to move the solder supply unit
to the original position. If necessary, make sure that the solder supply unit origin position check sensor
(1108:SSD ZERO POS) is functioning normally.
------------------------------
Code: 12056116
Display: "Interlock Cleaner Z"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the Z-axis is not at the origin position.
Remedy: Move the Z-axis to the Z-axis escape position (the position at which "X03C:Z ESC POS CHK
shows a value of 0). If necessary, make sure that the Z-axis camera interference prevention
interlocksensor (X03C:Z ESC POS CHK) is functioning normally.
------------------------------
Code: 12056117
Display: "Interlock Cleaner X"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the X-axis is not at the origin position.
Remedy: Use [CAMERA ESCAPE] on command page 550(2) to move the X-axis to the X-axis escape
position (the position at which X03D:X ESC POS CHK shows a value of 0). If necessary, make sure that
the X-axis camera interference prevention interlock sensor (X03D:X ESC POS CHK) is functioning
normally.
------------------------------
Code: 12056118
Display: "Interlock Cleaner SSD"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the SSD-axis is not at the origin
position.
Remedy: Use [ESCAPE POSITION MOVEMENT] on command page 544(4) to move the SSD-axis to the
SSD-axis escape position (the position at which 1108:SSD ZERO POS shows a value of 0). If necessary,
make sure that the solder supply unit origin position check sensor (1108:SSD ZERO POS) is functioning
normally.
------------------------------
Code: 12056119
Display: "Interlock Cleaner Holder Down"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the squeegee holder is down.
Remedy: Raise the squeegee (set Y02F:SQG HLDR UP to 0). If necessary, make sure that the squeegee
holder upper limit check sensor (X070:SQG HLDR UP) is functioning normally.
第 587 页
------------------------------
Code: 1205611A
Display: "Interlock Cleaner F Holder Up"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the front squeegee holder is down.
Remedy: Raise the front squeegee (set Y01D:F SQG HLDR UP to 0). If necessary, make sure that the front
squeegee holder upper limit check sensor (X070:F SQG HLDR UP) is functioning normally.
------------------------------
Code: 1205611B
Display: "Interlock Cleaner R Holder Up"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the rear squeegee holder is down.
Remedy: Raise the rear squeegee (set Y02F:R SQG HLDR UP to 0). If necessary, make sure that the rear
squeegee holder upper limit check sensor (X078:R SQG HLDR UP) is functioning normally.
------------------------------
Code: 1205611C
Display: "Interlock Conveyor Width Clutch"
Used by: GP6
Cause: The conveyor width clutch was turned on during automatic operation. This error occurs if the
conveyor width clutch turns on and interferes with the Z-axis during automatic operation.
Remedy: Use [UNLOCK] on command page 300(5)(1) to turn the conveyor width clutch off.If necessary,
make sure that the left and right conveyor width notch limit check sensors (X035:W_CLUTCH1_OFF
andX037:W_CLUTCH2_OFF) are functioning normally.
------------------------------
Code: 1205611D
Display: "Interlock Cleaner Connected"
Used by: GP6
Cause: The cleaner is interfering with the S-axis. This error occurs if the cleaner is connected to the S-
axis when the S-axis is moved to the printing position during automatic operation.
Remedy: Use [HEAD REMOVAL] on command page 553-2(3) to disconnect the cleaner from the S-axis. If
necessary, make sure that the lower cleaner connection check sensor, the cleaner connection
positionproximity check sensor, and the lower cleaner origin position check sensors (X05D:LW CLR CPL
CHK, X03E:CLNR NEAR CHK, and X05C:CLNR ZERO POS) are functioning normally.
------------------------------
Code: 1205611E
Display: 请待机Z轴
[Z escape]
Used by: GP6,GPX
Cause: Z轴与清洁器(移位)发生干涉。在清洁动作的清洁器移位前进时Z轴不在待机位置的情况下发生。 存在清洁
器和主工作台发生了干涉的可能性。 (GPX)
Remedy: 请将Z轴移动到Z轴待机位置(X03C:Z ESC POS CHK 为O的位置)。或者,请确认Z轴相机干涉防止联锁
传感器(X03C:Z ESC POS CHK)。 1.虽然稍重但是请用手将清洁器移动至退避位置。
2.发生了干涉时,请与本公司的Support联系。(GPX)
<img src="$LKEY_ERRIMG_MC$/1205611E.PNG">
------------------------------
Code: 1205611F
Display: "Move upper cleaner to escape position."
Used by: GP551
Cause: The upper cleaner is not at the escape position.
Remedy: Move the upper cleaner to the escape position.
------------------------------
第 588 页