FUJI错误代码查询.pdf - 第1180页
Remedy: Change the center tolerance (l center tolerance). ------------------------------ Code: 1C410115 Display: Used by: Cause: D center tolerance error. D direction center tolerance error. This error can occur at the e…
Display:
Used by:
Cause: The nozzle backlight diameter is small.
Remedy: Choose a larger backlight. Check the nozzle being used in Part data. Check PD.Back_light_min
------------------------------
Code: 1C410108
Display:
Used by:
Cause: The nozzle has not undergone training.
Remedy: Perform training on the nozzle. After training, do not change the nozzle and perform placing, or
the nozzle in vision processing memory will be different from the nozzle in use. Generally, because the
center of rotation will be the same, the results of vision processing correction will not be especially
effective, so when a small chip is picked the tolerance will increase, and slippage may result.
------------------------------
Code: 1C410109
Display:
Used by:
Cause: The vision processing segment failed inspection. This occurs when nozzle training has not been
carried out.
Remedy: Use the vision processing debug monitor to check for problem points. Segment detection error
occurs when the lead could not be detected. There are many reasons for this to happen:
1) The coarse edge was not done correctly and the lead was misplaced. Check the coarse edge description.
2) The lead size was incorrect so the lead could not be recognized. Check the element and segment size. If
the tolerance is very large, the lead will not be able to be recognized, and the sizes may vary widely. Check
l1, d1, l2, d2, l_size and e1-e4_tolerance.
3) The number of leads are wrong or there is no lead in the specified position. Check the element and
segment descriptions. Check l_count, d_count, l1, d1, l2 and d2. After nozzle training is performed,
transmit this information.
------------------------------
Code: 1C410110
Display:
Used by:
Cause: L size tolerance error. L direction segment training error. This error can occur during device
inspection.
Remedy: Change the edge tolerance (e2_tolerance and e4_tolerance) or check the segment size (l1, l2,
l_size).
------------------------------
Code: 1C410111
Display:
Used by:
Cause: D size tolerance check error. D direction segment tolerance error. This error can occur during
device inspection.
Remedy: Change the edge tolerance (e1_tolerance, e3_tolerance) and check the segment size (d1, d2,
d_size).
------------------------------
Code: 1C410114
Display:
Used by:
Cause: L center tolerance check error. L direction center tolerance error. Generally, this is a lead pitch
check error. This error can occur at the end of device inspection, and the corresponding tolerance check
cannot be disabled.
第 1179 页
Remedy: Change the center tolerance (l center tolerance).
------------------------------
Code: 1C410115
Display:
Used by:
Cause: D center tolerance error. D direction center tolerance error. This error can occur at the end of
device inspection, and the corresponding tolerance check cannot be disabled.
Remedy: Change the center tolerance (d center tolerance).
------------------------------
Code: 1C410116
Display:
Used by:
Cause: H position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410117
Display:
Used by:
Cause: V position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410118
Display:
Used by:
Cause: Angle position error.
Remedy: The pickup point has moved. This generally means that the part pickup rate is bad. Check the
pickup conditions at the monitor.
------------------------------
Code: 1C410120
Display:
Used by:
Cause: The part is too large.
Remedy: Check the relevant specifications.
------------------------------
Code: 1C410121
Display:
Used by:
Cause: There is no coarse edge in GD.
Remedy: Check the coarse edge in the GD editor.
------------------------------
Code: 1C410122
Display:
Used by:
Cause: When using a frontlight, a coarse edge is necessary.
Remedy: Check the device description.
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
第 1180 页
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410123
Display:
Used by:
Cause: Pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller. This
error generally means that part pickup rates are bad. Check pickup conditions at the monitor.
------------------------------
Code: 1C410124
Display:
Used by:
Cause: Pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller. This
error generally means that part pickup rates are bad. Check pickup conditions at the monitor.
------------------------------
Code: 1C410125
Display:
Used by:
Cause: A preset time limit has been exceeded.
Remedy: Set Part data's PD.Cam_speed lower. Check to see if the part can be placed at 100% cam speed.
------------------------------
Code: 1C410126
Display:
Used by:
Cause: Even though coarse edge was performed, the pickup tolerance is too large.
Remedy: Make the GD tolerances (pickup tolerance x, pickup tolerance y, rotation tolerance) smaller.
------------------------------
Code: 1C410127
Display:
Used by:
Cause: The coarse edge could not be found.
Remedy: Set up a correct coarse edge description. Check the following:
Coarse_edge_angle
Coarse_edge_l1
Coarse_edge_d1
Coarse_edge_l2
Coarse_edge_d2
Coarse_edge_e1_polarity
Coarse_edge_e3_polarity
break_rate
max_break
------------------------------
Code: 1C410128
Display:
Used by:
Cause: Training cannot be done because the pickup tolerance is too large.