FUJI错误代码查询.pdf - 第217页

machine. Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji. ------------------------------ Code: 11082001 Display: MTU is in OFF_LINE Mode Used by: MTU3,MTU4,MTU5 Cause: When the MTU…

100%1 / 5282
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A4
Display: Software limit: Check +Z
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Z axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A5
Display: Software limit: Check -Z
Used by: MTU3,MTU4,MTU5
Cause: During automatic operation, the Z axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A6
Display: Software limit: Check +T
Used by: MTU4
Cause: During automatic operation, the T axis moved to a position (in the plus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement, and set correct
data.
------------------------------
Code: 110810A7
Display: Software limit: Check -T
Used by: MTU4
Cause: During automatic operation, the T axis moved to a position (in the minus direction) outside the
software limit set in Proper data.
Remedy: Check the MTU Proper data and the items in part data related to movement and set correct data.
------------------------------
Code: 11081100
Display: 11081100
Used by: MTU3,MTU5
Cause: When the nozzle and the conveyor interfere with each other, the Z axis interlock sensor will be on
and the Y axis retract sensor off.
Remedy: Move the Y axis and Z axis away from the interference area.
------------------------------
Code: 11081120
Display: 11081120
Used by: MTU3,MTU5
Cause: The rear parts supply door was opened.
Remedy: Close the rear parts supply door.
------------------------------
Code: 11082000
Display: MTU is in ON_LINE Mode
Used by: MTU3,MTU4,MTU5
Cause: When the MTU was in the on-line mode, a command for off-line use was issued by the IP
第 216 页
machine.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082001
Display: MTU is in OFF_LINE Mode
Used by: MTU3,MTU4,MTU5
Cause: When the MTU was in the off-line mode, a command for on-line use was issued by the IP
machine.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082010
Display: Usable Proper Data has not been sent to MTU
Used by: MTU3,MTU4,MTU5
Cause: Proper data is not stored in the MTU.
Remedy: Transmit Proper data to the MTU.
------------------------------
Code: 11082011
Display: Usable Sequence Data has not been sent to MTU
Used by: MTU3,MTU4,MTU5
Cause: No program is stored in the MTU.
Remedy: Transmit a program to the IP machine.
------------------------------
Code: 11082012
Display: Usable Device Data has not been sent to MTU
Used by: MTU3,MTU4,MTU5
Cause: No program is stored in the MTU.
Remedy: Transmit a program to the IP machine.
------------------------------
Code: 11082020
Display: Zero setting not Completed
Used by: MTU4
Cause: Operation was attempted even though zero setting had not been completed.
Remedy: Switch the power off and then on again to both the IP machine and the MTU, and then perform
zero setting.
------------------------------
Code: 11082170
Display: Nozzle pressing overload detected
Used by: MTU4
Details: The sensor for detecting that the subnozzle is pressing too hard is activated.
Cause:
Remedy: The subnozzle is pressing down too hard. Check the part height, and the tray pickup offset.
Adjust the sensor.
------------------------------
Code: 11082200
Display: Transmission Format Error
Used by: MTU3,MTU4,MTU5
Cause: When communication takes place between the MTU and the IP machine, if the transmitted data
is not in the correct format, due to the effects of static electricity, transmission is reattempted 3 times. In
this case transmission was attempted three times but no correct response was obtained.
Remedy: Check that the there is no machine emitting a strong magnetic field along the route of the
communication cable between the MTU and the IP machine.
第 217 页
------------------------------
Code: 11082220
Display: Servo Power is ON
Used by: MTU3,MTU4,MTU5
Cause: While the servo power was on at the MTU, the IP machine issued a command for when the servo
power is off.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082221
Display: Servo Power is OFF
Used by: MTU3,MTU4,MTU5
Cause: While the servo power was off at the MTU, the IP machine issued a command for when the servo
power is on.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082230
Display: Operation Mode is set to OPERATE
Used by: MTU3,MTU4,MTU5
Cause: While the MTU was operating, commands for use when the MTU is stopped were issued by the IP
machine.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082231
Display: Operation Mode is set to Stop
Used by: MTU3,MTU4,MTU5
Cause: While the MTU was operating, commands for use when the MTU is stopped were issued by the IP
machine.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082240
Display: Remove empty tray
Used by: MTU4
Cause: An emergency stop occurred after the last part in the tray had been picked up and before the tray
was ejected. Because the emergency stop occurred during the tray eject cycle, the MTU is unsure of the
condition of the tray. Therefore it is necessary for the operator to check the tray and remove it.
Remedy: Manually remove the empty tray.
------------------------------
Code: 11082250
Display: Operation Impossible MTU Operation Panel in Use
Used by: MTU3,MTU4,MTU5
Cause: Operation was being performed at the MTU terminal when AUTO, STEP or another command was
executed at the IP machine.
Remedy: At the MTU terminal us
------------------------------
Code: 110822EE
Display: Command can not be Executed due to Alarm
Used by: MTU3,MTU4,MTU5
Cause: While the MTU was in an error condition, an instruction to start production was issued by the IP
machine.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
第 218 页