FUJI错误代码查询.pdf - 第840页
"?" indicates the module number (QP2). "****" indicates the error code. Remedy: Switch the power off and then on, then restart operation. ------------------------------ Code: 1207F?32 Display: "S…
------------------------------
Code: 1207F?28
Display: "SCU?(ICM,PMC?) Error Code:********"
"TZ-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The time between characters exceeds 100 ms.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?29
Display: "SCU?(ICM,PMC?) Error Code:********"
"TZ-Axis Servo Alarm Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?2A
Display: "SCU?(ICM,PMC?) Error Code:********"
"TZ-Axis Servo Alarm Axis Alarm Still Occuring"
Used by: QP242
Cause: A command was received before the machine was reset.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?2B
Display: "SCU?(ICM,PMC?) Error Code:********"
"TZ-Axis Servo Alarm Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?30
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Comm Error"
Used by: QP242
Cause: Cannot communicate with the servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check that the servo unit is properly connected.
------------------------------
Code: 1207F?31
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
第 839 页
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?32
Display: "SCU?(PMC?,ICM) Error Code:********"
"The TZ-Axis Servo is OFF or an alarm is active."
Used by: QP242
Cause: The TZ-axis servo is off or an alarm is active.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: If the TZ-axis servo is off, check that the servo controller is being supplied with power. If an
alarm is active, clear the alarm and restart operation.
------------------------------
Code: 1207F?33
Display: "SCU?(PMC?,ICM) Error Code:********"
"A TZ-axis servo parameter have not been set."
Used by: QP242
Cause: Check the parameters for the TZ-axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Set the TZ-axis servo parameters, supply power and restart operation.
------------------------------
Code: 1207F?34
Display: "SCU?(PMC?,ICM) Error Code:********"
"Cancellation by TZ-Axis stop command."
Used by: QP242
Cause: Axis operation terminated because a separate error occurred during communication.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?35
Display: "SCU?(PMC?,ICM) Error Code:********"
"Error prior to TZ-Axis Encorder Counter Operation"
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?36
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Encorder Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?37
第 840 页
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Encorder Counter Recieving Error"
Used by: QP242
Cause: An error occurred at the TZ-axis servo controller when receiving data.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?38
Display: "SCU?(PMC?,ICM) Error Code:********"
"Disconnected TZ-Axis"
Used by: QP242
Cause: TZ-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?39
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Servo Controller Timeout"
Used by: QP242
Cause: The TZ-axis timed out.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?3A
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?3B
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Servo Controller Axis Stop"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
Code: 1207F?3C
Display: "SCU?(PMC?,ICM) Error Code:********"
"TZ-Axis Servo Limit Error"
Used by: QP242
Cause: The maximum or minimum position for the axis controlled by the Robustshin servo motor has
been exceeded. Alternatively, something may be obstructing the overtravel sensor for that axis.
"?" indicates the module number (QP2).
第 841 页