FUJI错误代码查询.pdf - 第128页

Cause: The solder supply speed setting is outside the valid range. Remedy: Make sure that the solder supply speed setting in the production program is from 0 to 200 [mm/sec]. If a value of 0 has been set in the productio…

100%1 / 5282
Remedy: Set the indexing type in the program header to one of the following values: 0, 2, 3, 4, or 5. These
settings indicate 7-inch indexing, 5-2 indexing, 4-3 indexing, 3-4 indexing, and 2-5 indexing, respectively.
------------------------------
Code: 1101E02E
Display: Same as code
Used by: QP132
Cause: Different indexing types are specified for programs having the same family name.
Remedy: Change the family name, or set the indexing types to the same value.
------------------------------
Code: 1101E02F
Display: Same as code
Used by: QP132
Cause: Unexecutable sequences have occurred because the indexing type in the program header has
been set to 7-inch single indexing. This error occurs when the program is checked upon transmission.
Remedy: Check the mounting coordinates in the sequence data. If the coordinates are correct, set the
indexing type in the program header to a value other than 0.
------------------------------
Code: 1101E030
Display: Same as code
Used by: QP132
Cause: A family name has not been set in the program header. This error occurs when the program is
checked upon transmission.
Remedy: Set a family name in the program header.
------------------------------
Code: 1101E031
Display: Same as Code.
Used by: QP132
Cause: The value set for the loading distance position for tandem loading ("PCB distance") has been set to
a positive value.
Remedy: Set this item to a negative value.
------------------------------
Code: 1101E032
Display: 与编码相同
Used by: GP551,GP6,GPX,NXTP
Cause: 特殊清洁计数器超出范围。
Remedy: 请确认生产程序的Special_cleaning_interval。
范围:0~65000[块]
请确认FujiFlexa上设定的特殊自动清洁计数器。
范围:0~9999[块](GPX,NXTP)
自动清洁为0块时,不能对特殊清洁进行1块以上的设定(GPX,NXTP)。
------------------------------
Code: 1101E033
Display: Same as code
Used by: GP2,GP3,GP551,GP6
Cause: The pressure measurement interval setting is outside the valid range.
Remedy: Make sure that the "Press_meas_interval" parameter in the production program is set to a value
from 0 to 65000 [boards].
------------------------------
Code: 1101E034
Display: Same as code
Used by: GP551,GP6
第 127 页
Cause: The solder supply speed setting is outside the valid range.
Remedy: Make sure that the solder supply speed setting in the production program is from 0 to 200
[mm/sec]. If a value of 0 has been set in the production program, check the solder supply speed setting in
the Proper data.
------------------------------
Code: 1101E035
Display: Same as code
Used by: GP2,GP3,GP551,GP6
Cause: Squeegee/Pressure Rear, Squeegee/Pressure Front, or Squeegee/Solder Low Limit at the
production program is out of range.
Remedy: Verify the data input range for the production program.
Squeegee/Pressure Rear: 0.10 to 9.99
Squeegee/Pressure Front: 0.10 to 9.99
Squeegee/Solder Low Limit: -9.99 to -0.10
The following are the ranges at machines with a max. print pressure of 20-kg.
Squeegee/Pressure Rear: 0.10 to 20.0
Squeegee/Pressure Front: 0.10 to 20.0
------------------------------
Code: 1101E036
Display: Same as code
Used by:
Cause: The value specified at the item "Solder_supply_stroke" in the production program is outside the
acceptable range.
Remedy: Check the value set in item "Solder_supply_stroke" of the production program. The acceptable
range is 1-510 [mm]. (For GP-6 single squeegee machines the acceptable range is 1-420 [mm] and for
double squeegee machines the acceptable range is 1-460 [mm]. For GP-5 single squeegee machines the
acceptable range is 1-320 [mm] and for double squeegee machines the acceptable range is 1-360 [mm].)
------------------------------
Code: 1101E037
Display: Same as code.
Used by:
Cause: Size_x and Size_y values have not been set in mark data despite the fact that the production
program contains block skip marks.
Remedy: Retransmit the program after setting the Size_ x and Size_y values in mark data.
------------------------------
Code: 1101E038
Display: 与该编码相同
Used by: GP551,GP6,GPX,NXTP
Cause: 生产程序的Screen Status为规定外。
网版类型为范围外。(GPX,NXTP)
Remedy: 请确认生产程序的数据Screen Status。
GP6的框设定如下所示。
新FUJI框:0000 0000 0000 0001 (1H)
其他公司框/旧FUJI框网版更换完毕:0000 0000 0000 0000 (0H)
旧FUJI框网版无更换:0000 0000 0000 1000 (8H)
可以设定的网版类型如下所示。
·0:650x680mm
·1:550x650mm(GP6框,NXTP-M35)
·2:650x550mm
·3:23英寸四方形
·4:29英寸四方形
第 128 页
·5:450x450mm(GPX,NXTP-M25)
·9:550x600mm(NXTP-M35)
------------------------------
Code: 1101E039
Display: Index motion type error.
Used by: QP132
Cause: The index motion type is out of range. The index motion type depends on the size of the pallet.
For example, with an 8 inch pallet, any value besides, "8", "35", "44" and "53" results in an error.
Remedy: If this error occurs when the production program is transmitted, enter the correct value for
"Index_motion" in the production program.
------------------------------
Code: 1101E03A
Display: Wrong family condition
Used by: QP132
Cause: A different-family program was transmitted to the foreground while boards were in the machine.
Remedy: Do not transmit different-family programs to the foreground when boards are in the machine.
Check the program's family name.
------------------------------
Code: 1101E03B
Display: Wrong family condition
Used by: QP132
Cause: Wrong family condition.
Remedy: Check the family condition.
------------------------------
Code: 1101E03C
Display: Wrong tandem program condition
Used by: QP132
Cause: Wrong tandem program condition.
Remedy: Check the tandem program setting.
------------------------------
Code: 1101E03D
Display: Wrong index motion type
Used by: QP132
Cause: An index motion type of "8" ("88" at 16-inch pallets) was designated at a program where single
indexing production is impossible due to the placing coordinate configuration.
Remedy: Change the index motion type.
------------------------------
Code: 1101E03E
Display: 与编码相同
Used by: CP643, GPX,NXTP
Cause: 电路板厚度在范围之外
Remedy: 请确认生产程序的Pcb_Thickness(MCS时)。请确认生产程序的General PCB Data Thickness(F4G时
)的数值。如果是CP643,由于贴装吸嘴的基准是按照电路板下面被测定的,因此必须输入电路板厚度。范围是
0.30~4.00[mm]。
范围为 0.4mm~6。0mm。(GPX,NXTP)
------------------------------
Code: 1101E03F
Display: same as code.
Used by: CP643
Cause: The clearance between boards is less than 15 mm.
Remedy: Set the item "PCB_DISTANCE" equal to the item "Pcb_X" plus 15 mm or more. The item
第 129 页