Cause: The program transmission data is incorrect. Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of how to cope with this error. ------------------------------ Co…
Cause: Even though the program was transmitted, the necessary memory cannot be retrieved.
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A233
Display: event error
Used by:
Cause: Unable to link the event even though the program was transmitted.
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A234
Display: Part data read error
Used by:
Cause: There is no Part data in MCS. Alternately, the offset table has moved.
Remedy: Use the file services directory to check the file. If the file exists, save and correct the Part data.
------------------------------
Code: 2100A235
Display: LUX ERROR
Used by:
Cause: The pallet transmission filename does not match.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A236
Display: LVX ERROR
Used by:
Cause: This is a pallet transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A237
Display: GVX ERROR
Used by:
Cause: Generic device transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A238
Display: GQXAA00 ERROR
Used by:
Cause: The GD file does not exist in MCS.
Remedy: Use the file services directory to check the file.
------------------------------
Code: 2100A239
Display: GDXAA00 ERROR
Used by:
Cause: The GD file does not exist in MCS.
Remedy: Use the file services directory to check the file.
------------------------------
Code: 2100A23A
Display: DFX ERROR
Used by:
第 2005 页
Cause: The program transmission data is incorrect.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A23B
Display: DTXAB00 ERROR
Used by:
Cause: During downloading, an answer was not received from the machine within the preset time limit
(between dT and DTO).
Remedy: Check that the machine and MCS are both booted up (HELPS).
------------------------------
Code: 2100A23C
Display: DTXAB01 ERROR
Used by:
Cause: While the program was being downloaded, a communication error was returned from the
machine.
Remedy: Select the [Ctrl] and [E] keys from the UCI menu to get a display of errors. Refer to the errors
from the machine for more details.
------------------------------
Code: 2100A23D
Display: pallete file open error
Used by:
Cause: The pallet file could not be found when the CP5 program was transmitted.
Remedy: If ".nickname" is appended to the program name, the production program name is the same as
the pallet filename. If ".nickname" is not appended to the program name, use the file services directory to
check whether or not there is a production program filename with this appendage.
------------------------------
Code: 2100A23E
Display: File access error
Used by:
Cause: Unable to access a file necessary for transmission.
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A23F
Display: MC nickname not appended to progname
Used by:
Cause: The term ".nickname" is not appended to the program.
Remedy: Append ".nickname" to the program.
------------------------------
Code: 2100A240
Display: nozzle file open error
Used by:
Cause: The nozzle file at the CP5 program could not be opened.
Remedy: Check that the nozzle file has been specified. If it has not, use the file services directory to
check the file.
------------------------------
Code: 2100A241
Display: next device data error
Used by:
Cause: The next device is not set correctly. Alternately, there are more than 30 next devices specified.
Remedy: Check that the next device settings are looping. Set the final next device to be the original next
第 2006 页
device. Check that more than 30 next devices are not in use.
------------------------------
Code: 2100A242
Display: DTXAB02 ERROR
Used by:
Cause: The nozzle file was not specified in the program being downloaded.
Remedy: Check that the nozzle file has been specified. If it has not, use the file services directory to
check the file (HELPS).
------------------------------
Code: 2100A243
Display: DTXAB03 ERROR
Used by:
Cause: The pallet file was not specified in the program being downloaded.
Remedy: If ".nickname" is appended to the program name, the production program name is the same as
the pallet filename. If ".nickname" is not appended to the program name, use the file services directory to
check whether or not there is a production program filename with this appendage.
------------------------------
Code: 2100A245
Display: KWX ERROR
Used by:
Cause: This is a second Proper data transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A246
Display: KXX ERROR
Used by:
Cause: This is a third Proper data transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A247
Display: KSZ ERROR
Used by:
Cause: This is a second Proper data reverse transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A248
Display: KTZ ERROR
Used by:
Cause: This is a third Proper data reverse transmission check error.
Remedy: Refer to the error information on the machine. Refer to error code section 1102**** for details of
how to cope with this error.
------------------------------
Code: 2100A301
Display: /pipe/transmit_controller open error
Used by:
Cause: The TC pipe could not be opened.
Remedy: When this error occurs and transmission cannot be carried out, re-boot MCS.
------------------------------