Code: 1205402F Display: "Air Cylinder Cycle Alarm Cleaner Released" Used by: GSP5,GP551,GP6 Cause: Removal of the notch required longer than the specified time. Remedy: Use an I/O command to check the sensor. -…

100%1 / 5282
Cause: The automatic screen replacement rear screen clamper could not be opened in the specified time.
Remedy: Make sure that nothing is obstructing the operation of the automatic screen replacement rear
screen clamper .
------------------------------
Code: 12054029
Display: "Cycle alarm: Check SCR" (GSP)
Used by: GSP2,GSP3
Cause: One of the following conditions occurred during screen replacement: the screen was not securely
clamped, the frame positioning sensor has not turned on (because the sensor is not in the properposition),
or the frame pressure check sensor has not turned on (for the same reason).
Remedy: Check the position of the screen, and make sure that it is securely clamped. Check the sensor
positions.
------------------------------
Code: 1205402A
Display: "Cycle alarm: Stocker" (GSP)
Used by: GSP2,GSP3
Cause: The stocker did not arrive at the upper or lower limit within the expected time.
Remedy: Make sure that nothing is obstructing the stocker's vertical movement. Inspect the machine.
------------------------------
Code: 1205402B
Display: "Cycle alarm: side clamp" (GSP)
Used by: GSP2,GSP3,GSP5,GP551,GP6,NXTP
Cause: An instruction was issued to open or close the side clamp, but the side clamp couldn't be opened
or closed within a 1-second period.
Remedy: Use the loader clamp command to clamp a board, then use an I/O command to make sure that
the input from sensor 1-29 PCB_SIDE_UNCLAMP is functioning normally.If the sensor does not respond
properly, adjust the sensor position. Otherwise, raise the "clamp_press" setting in the production
program.
<img src="$LKEY_ERRIMG_MC$/1205402B.PNG">
------------------------------
Code: 1205402C
Display:
Used by: CP4-1,CP4-2,CP4-3,IP3
Cause: The nozzle change cylinder could not retract within the specified time limit.
Remedy: Use the I/O board to check that the cylinder can advance and retract.Check that the appropriate
sensors turn on and off at the advance and retract limit positions.
------------------------------
Code: 1205402D
Display:
Used by: IP3
Cause: The reflow head could not finish rotating within the specified time limit.
Remedy: Check that the reflow head rotates smoothly, using the output section of the I/O board. Check
that the head is ON at 0 deg. and 90 deg..
------------------------------
Code: 1205402E
Display:
Used by: IP3
Cause: The reflow nozzle could not raise or lower itself within the specified time limit.
Remedy: Check that the reflow nozzle raises and lowers smoothly, using the output section of the I/O
board. Check that the sensors are on at the upper and lower limit positions.
------------------------------
第 547 页
Code: 1205402F
Display: "Air Cylinder Cycle Alarm Cleaner Released"
Used by: GSP5,GP551,GP6
Cause: Removal of the notch required longer than the specified time.
Remedy: Use an I/O command to check the sensor.
------------------------------
Code: 12054030
Display: "Air Cylinder Cycle Alarm Cleaner Connected"
Used by: GSP5,GP551,GP6
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use an I/O command to check the sensor (GSP5, GP6).
------------------------------
Code: 12054031
Display: 周期异常 汽缸 清洁器工作头关闭
Used by: GP551,GP6,GPX,NXTP
Cause: 关闭清洁器工作头超过了规定时间以上。 清洁器上下的进入端或者退出端没有在规定的时间内ON。
清洁器的上升端,下降端的传感器同时ON了。 (GPX)
Remedy: 请通过I/O确认传感器。 1.请除去清洁器上下时的障碍物。
2.请使用I/O进行清洁器上下进入确认,清洁器上下解除确认的传感器的检查。(RX018,019)(请与本公司的
Support联系)
3.UpDown Sensor Adjustment:请进行清洁器上升下降端的传感器位置的调整。(GPX)
<img src="$LKEY_ERRIMG_MC$/12054031.PNG">
------------------------------
Code: 12054032
Display: 周期异常 汽缸 清洁器工作头开启
Used by: GSP5,GP551,GP6,GPX,NXTP
Cause: 开启清洁器工作头超出规定时间以上。
Remedy: 请通过I/O确认传感器。
<img src="$LKEY_ERRIMG_MC$/12054032.PNG">
------------------------------
Code: 12054033
Display:
Used by: GSP5
Cause: The specified operation did not finish within the specified time.
Remedy: The cylinder which moves the solder supply in the Y-direction is broken or disconnected. Check
the cylinder movement and check the connections.
------------------------------
Code: 12054034
Display:
Used by: GSP5,GP6,NXTP
Cause: The specified operation did not finish within the specified time.
Remedy: The cylinder which moves the solder supply up and down is broken, disconnected or is being
prevented from moving by some interfering object. Check the cylinder movement, check the connections
and check for any interfering objects.
<img src="$LKEY_ERRIMG_MC$/12054034.PNG">
------------------------------
Code: 12054035
Display:
Used by:
Cause: The X-chuck could not open and close in the specified time.
Remedy: Check that the load on the cylinder is not unreasonable.
第 548 页
------------------------------
Code: 12054036
Display:
Used by:
Cause: The X-transport could not open and close in the specified time.
Remedy: Check that the load on the cylinder is not unreasonable.
------------------------------
Code: 12054037
Display:
Used by: GSP5
Cause: Mask reception advance or retraction takes too long.
Remedy: Check that the mask reception advance and retract limit sensors work.
------------------------------
Code: 12054038
Display:
Used by: GSP5
Cause: The solder recovery ascent or descent takes too long.
Remedy: Check that the solder recovery ascent or descent limit sensors work.
------------------------------
Code: 12054039
Display:
Used by: GSP5
Cause: A camera station cycle alarm has occurred. The camera station could not move to its target
position within the specified time. Alternately, the advance or retract limit sensors are not working
properly.
Remedy: Check for interference at the camera station.Check the advance and retract limit sensors.
------------------------------
Code: 1205403A
Display: 周期异常 刮刀架
Used by: GSP5,GP551,GP6,GPX
Cause: 在刮刀架的上升或下降中发生了超时。
Remedy: 请确认刮刀架的传感器的输入。
<img src="$LKEY_ERRIMG_MC$/EI0024.bmp">
------------------------------
Code: 1205403B
Display: Cycle Alarm Stencil Top Clamp (GSP5, GP6)
Used by: GSP5,GP551,GP6
Cause: The top clamp on the stencil did not work correctly. Or the stencil top clamp check sensor failed
to work correctly.
Remedy: Check the output and input of the stencil top clamp sensor using the I/O check operation.
------------------------------
Code: 1205403C
Display:
Used by:
Cause: The stroke cannot ascend or descend. Alternately, the stroke lower limit sensor is broken.
Remedy: Check the operation of the stroke at the I/O board, and check the sensors.
------------------------------
Code: 1205403D
Display:
Used by:
Cause: The stroke frame clamper cannot operate. Alternately, the stroke frame clamper confirmation