FUJI错误代码查询.pdf - 第1145页
Used by: Cause: This error is the result of the board clamp on the in-conveyor side being in the clamped status. Remedy: Unclamp the board clamp on the in-conveyor side. Check the operation of the entry board pusher clam…
Code: 15040503
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040505
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040506
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040507
Display: CANNOT GET PCB DATA
Loader error: 15040507
Used by: QP132
Cause: The board data area could not be saved.
Remedy: Carry out the unload operation and the flush out operation in succession and then restart.
------------------------------
Code: 15040508
Display: PCB_AVAILABLE_NG_TUP
LD_ERR 15040508
Used by:
Cause: In the case of SMEMA compatibility, a board unload prohibition signal from the previous process
is preventing unloading from taking place.
Remedy: Check the status of the signal line connection from the previous process.
------------------------------
Code: 15040509
Display: IN INTERLOCK PLT ARRIVED OFF
LD_ERR 15040509
Used by:
Cause: The pallet on the production conveyor popped off the loader.
Remedy: Return the pallet to the loader or slide the pallet onto the production conveyor. Check the
operation of the loading pallet-arrival-check 1 sensor.
------------------------------
Code: 1504050A
Display: IN INTERLOCK PLT PASSED ON
Used by: QP132
Cause: The return conveyor pallet popped up onto the loader.
Remedy: Set the pallet on the loader or return it to the return conveyor. Check the operation of the
loading pallet-arrival-check 2 sensor.
------------------------------
Code: 1504050B
Display: IN INTERLOCK PCB CLAMP ON
LD_ERR 1504050B
第 1144 页
Used by:
Cause: This error is the result of the board clamp on the in-conveyor side being in the clamped status.
Remedy: Unclamp the board clamp on the in-conveyor side. Check the operation of the entry board
pusher clamp limit sensor.
------------------------------
Code: 1504050C
Display: IN INTERLOCK PCB PASSED ON
LD_ERR 1504050C
Used by:
Cause: The in-conveyor board popped up onto the loader.
Remedy: Set the board on the loader or return it to the in-conveyor. Check the operation of the in-
conveyor board pass-through-check sensor.
------------------------------
Code: 1504050D
Display: IN INTERLOCK HOOK PULLED OFF
LD_ERR 1504050D
Used by:
Cause: The PI-axis board hooks was not in the released status.
Remedy: Release the PI-axis board hooks. Check the operation of the PI-axis hook release status sensor.
------------------------------
Code: 1504050E
Display: IN INTERLOCK PLT ARRIVED2 OFF
LD_ERR 1504050E
Used by:
Cause: There was a pallet on the loader when the loader was retracting.
Remedy: Check the operation of the loading pallet-arrival-check 2 sensor.
------------------------------
Code: 1504050F
Display: IN INTERLOCK SS NOT ORG POS
LD_ERR 1504050F
Used by:
Cause: The SS-axis is not at its origin position.
Remedy: Move the SS-axis to its origin position.
------------------------------
Code: 15040510
Display: IN INTERLOCK PLT PUSH ON
Loader error: 15040510
Used by: QP132
Cause: When the pallet loader attempted to move to its extended position or, to its retracted position, the
pallet pusher was not at the retracted position.
Remedy: Check the operation of the return conveyor board pusher (X04B: RCV PUSH BWEND) using I/O
commands and adjust if necessary.
------------------------------
Code: 15040511
Display: X051 P_IN_PASS_CK Error
Used by: QP132
Cause: Either the sensor (X051 P_IN_PASS_CK) is defective, or a pallet is not unloader from the pallet
loader.
Remedy: Adjust the sensor (X051 P_IN_PASS_CK) . If a pallet is not unloader, move it to the appropriate
position.
------------------------------
第 1145 页
Code: 15040512
Display: In-shifter pallet positioning error.
Used by: QP132
Cause: The pallet is not at the correct position or the pallet arrival sensor (X050 P. IN ARRV CK) is not
functioning correctly.
Remedy: Manually move the pallet on the in-shifter to the left and confirm that it is detected by the pallet
arrival sensor. If the pallet is not detected, check the condition of the sensor.
------------------------------
Code: 15040600
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040601
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040602
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040603
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040604
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040605
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040606
Display: Abolished.
Used by: QP122
Cause: Abolished.
Remedy: Abolished.
------------------------------
Code: 15040607
第 1146 页