FUJI错误代码查询.pdf - 第723页
Used by: QP242,QP201,QP202,QP203,QP132 Cause: The axis is not at the origin position. (value replacing "?" is module number; error code appears in place of asterisks) (value replacing "??" is module n…
"Parts release error"
Used by: QP203
Cause: The placing head has returned without placing the heat spreader or the spring clip.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the part(s) which caused the error. Check to ensure the mechanical chuck and the
parts confirmation sensor (CLIP DETECT) are operating correctly.
------------------------------
Code: 12070?2C
Display: "ICM(PMC?,SCU?) Error Code:********"
"Clip pickup confirm. error"
Used by: QP203
Cause: Failed to pick-up the spring clip correctly.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check to see if the spring clip has been dropped on the supply tray. Check to ensure the
mechanical chuck and the parts confirmation sensor (CLIP DETECT) are operating correctly.
------------------------------
Code: 12070?2D
Display: "ICM(PMC?,SCU?) Error Code:********"
"Clip plmt confirm. error"
Used by: QP203
Cause: Failed to attach the spring clip.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check to ensure the spring clip has been attached correctly. If there is a problem, remove the
heat spreader and spring clip from the placing head, then check the placement coordinates. If the spring
clip is attached correctly, check that the block number settings in the recipe match the block number at
the placement target. Check to ensure the spring clip attachment confirmation sensors (CLIP CHK1 to 10)
are operating correctly.
------------------------------
Code: 12070?2E
Display: "ICM(PMC?,SCU?) Error Code:********"
"Parts at placement position"
Used by: QP203
Cause: Placement was not possible because the target position is already occupied.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the position for which the error occurred. If the position is occupied, change your
sequence data in the recipe. If the position is not occupied, check to ensure the spring clip attachment
confirmation sensors (CLIP CHK1 to 10) are operating correctly.
------------------------------
Code: 12070?2F
Display: "ICM(PMC?,SCU?) Error Code:********"
"Parts could not be rejected"
Used by: QP203
Cause: Failed to dump parts.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove any parts on the placing head. Also, check that there are no errors with the mechanical
chuck or the parts confirmation sensor (CLIP DETECT).
------------------------------
Code: 12070?30
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Not at Origin Position" (QP2)
PM?? ERROR Code:******** (QP132)
第 722 页
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?31
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"M/C Stop (Parts Runout)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has stopped because it has run out of a component. This code is used in
notification between the PMC and the MC; it is never actually used in notification to the host computer.
(The host computer is notified of expended components using error code 12040104.)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Supply components.
------------------------------
Code: 12070?32
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Improper XY Data" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command contains insufficient XY coordinate data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?33
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A RELEASE command was received even though the FREEZE command has not been received.
?? indicates the module number. **** indicates the command name in which the error occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?34
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Servo Power ON" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because the servo's power supply is on.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
第 723 页
------------------------------
Code: 12070?35
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Recovery Operation" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine is recovering. (This code is used for internal processing.)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?36
Display: PM?? ERROR Code:********
Used by: QP132
Cause: The pallet ID is incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Reread the ID using the ID rereading command. Restart the machine, or execute flush out
processing.Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?37
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No part in tray pocket"(QP203)
"Parts Runout" (Other QP2s,NP2,QP3)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP2,QP3
Cause: The machine has run out of a component. (This code is used for internal processing by the QP1.
The QP2 reports this code to its host computer.)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether there are parts in the tray pockets.(QP203)
Supply components.(Other QP2s,NP2,QP3)
Open and close the safety door in the case where the feeder is either STU1 or STU2.(QP3)
------------------------------
Code: 12070?38
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unexecutable(Servo Lock)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the servo is locked.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
第 724 页