FUJI错误代码查询.pdf - 第1139页
conveyed properly, check to see if the sensors (X0CC, X0CD) are operating properly. ------------------------------ Code: 15040431 Display: Out-carrier unclamp sensor input error. Used by: CP-732E, CP-742ME, CP-742E Cause…
Code: 1504042A
Display: Out-conveyor panel set error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance problem on the out-conveyor is preventing proper panel conveyance. During
single-board production, 2 boards were unloaded from the out-carrier. Alternatively, during double-board
production, there was no interval between the panel s unloaded from the out-carrier (Out 1, Out 2 panel
interval sensors are off).
Remedy: Verify that the number of panel s on the out-lifter matches the number of panel s designated by
the current production mode (single or double board production). If the panel s are being conveyed
properly, verify that the sensors (X0C7, X0C9, X0CA) are operating properly. This error may also occur if
there is a mid-stopper problem which results in the panel s not stopping at the stopper position. The
panel interval sensor should be on when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504042B
Display: Out-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Within 1 second after the out-carrier retract command was executed in order to unload the out-
carrier panel to the out-lifter, a panel was detected on the out-lifter by a sensor.
Remedy: Check to see if the sensors (X0C7, X0C9, X0CA) are operating properly. The panel interval
sensor should be on when a panel is absent, and off when a panel is present.
------------------------------
Code: 1504042C
Display: Out-conveyor panel sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier 1 panel sensor or the out-carrier 2 panel sensor switched on when panel
unloading from the XY-table to the out-carrier was attempted. The out-carrier 1 panel sensor or the out-
carrier 2 panel sensor remained on for 0.5 seconds when the XY-table was at its DOWN limit or loading
position with the out-carrier open at its advance limit position.
Remedy: Check to see if the sensors (X0CC, X0CD) are operating properly.
------------------------------
Code: 1504042D
Display: Out-lifter cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP limit sensor failed to switch on. The out-lifter was lowered but the DOWN limit
sensor failed to switch on within the prescribed time period (3 secs.).
Remedy: Check to see if the out-lifter is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0D0, X0D1) are operating properly.
------------------------------
Code: 1504042E
Display: Out-carrier cycle error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter advance limit sensor failed to switch on. The out-carrier was retracted but the
retract limit sensor failed to switch on within the prescribed time period (8 secs.).
Remedy: Check to see if the out-carrier is operating smoothly. If operation is smooth, but the error still
occurs, check to see if the sensors (X0CE, X0CF) are operating properly.
------------------------------
Code: 1504042F
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: At the out-carrier panel check, the out-carrier 1 panel sensor turned on.
Remedy: Check the panel conveyance condition. If this error occurs even though the panel s are being
第 1138 页
conveyed properly, check to see if the sensors (X0CC, X0CD) are operating properly.
------------------------------
Code: 15040431
Display: Out-carrier unclamp sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier unclamp sensor input error.
Remedy: Verify that the sensors (X0D2 to X0D5) are operating properly.
------------------------------
Code: 15040432
Display: Out-carrier clamp sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier clamp sensor input error.
Remedy: Verify that the sensors are operating properly.
------------------------------
Code: 15040433
Display:
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier panel clamp limit sensors at fixed-rail side advance limit, and adjustable-rail side
advance limit are not responding.
Remedy: Verify that the sensors (X0D4 to X0D5) are operating properly.
------------------------------
Code: 15040434
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After the out-carrier clamped the panel and moved to the retract limit position, the Out 1 panel
arrival sensor switched off.
Remedy: Verify that the Out 1 panel arrival sensor is operating properly.
------------------------------
Code: 15040435
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: After the out-carrier clamped the 2 panel s and moved to the retract limit position, the Out 2
panel arrival sensor switched off.
Remedy: Verify that the Out 2 panel arrival sensor is operating properly.
------------------------------
Code: 15040436
Display: New panel step command error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An illegal new panel step command was executed.
Remedy: Use the machine's trace function to obtain trace data.
------------------------------
Code: 15040437
Display: Loader command error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: panel s cannot be loaded to the in-loader. Although an in-carrier loading command was
executed, the in-loader is disabled due to one of the following 4 conditions:
(1)There is no panel on the in-lifter (in-lifter panel sensor detects no panel ).
(2)The in-carrier is at its advance limit position, and a panel is clamped (in-lifter panel sensor detects a
panel ).
(3)In-carrier is at its retract limit position, and a panel absent status cannot be confirmed on the in-
carrier.
第 1139 页
(4)Because the in-carrier is at neither the advance limit nor the retract limit position, a panel absent
status cannot be confirmed on the in-carrier.
Loading to the out-lifter is not possible. Although an out-lifter loading command (out-carrier panel is
unloaded to the out-lifter) was executed, the out-loader is disabled due to one of the following 4
conditions:
(1)There is a panel on the out-conveyor (out-conveyor panel sensor has detected a panel ).
(2)The out-carrier is at its advance limit position, and the panel cannot be clamped (out-carrier panel
sensor detects no panel ).
(3)The out-carrier is at its retract limit position, and a panel present status cannot be confirmed on the
out-carrier.
(4)Because the out-carrier is at neither the advance limit nor the retract limit position, a panel present
status cannot be confirmed on the out-carrier.
An improper panel unloading command was executed at the loader while in the IDLE mode.
An improper unloading command was attempted at the loader.
An improper loader command was attempted during operation (AUTO, COMMAND, IDLE mode) with the
out-loader ready to receive a panel from the main lifter.
Improper operation signal switched on during AUTO mode operation.
Improper operation signal switched on during COMMAND mode operation.
Improper operation signal switched on during IDLE mode operation.
An improper command was attempted while measuring the in-loader panel conveyance time.
An improper command was attempted while measuring the out-loader panel conveyance time. An
improper operation signal switched on while measuring the out-loader panel conveyance time.
There is no operation corresponding to the issued command.
Remedy: When improper command errors occur, use the machine's trace function to obtain trace data.
------------------------------
Code: 15040439
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance error occurred at the out-carrier. The Out 1 panel arrival sensor switched off
at some point between the start of out-lifter UP motion and the completion of panel unloading to the out-
lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
Code: 1504043A
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A panel conveyance error occurred at the out-carrier. The Out 2 panel arrival sensor switched off
at some point between the start of out-lifter UP motion and the completion of panel unloading to the out-
lifter.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
Code: 1504043B
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: When unloading a panel to the out-lifter, the out-carrier panel sensor switched on when the out-
carrier moved to its advance limit position.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating properly.
------------------------------
第 1140 页