------------------------------ Code: 12056103 Display: Vacuum Holder Too Large Used by: GP551,GP6 Cause: The size of the board vacuum holder does not match the conveyor width. If the Z-axis is raised under this condition…
Remedy: 请取得发生错误时的跟踪数据,与本公司电话服务中心联络。
<img src="$LKEY_ERRIMG_MC$/12056057.PNG">
------------------------------
Code: 12056058
Display: 机内无电路板
Used by: NXTP
Cause: 执行机内(主搬运轨道)电路板的使用指令时没有发现电路板。
Remedy: 请打开门并放入电路板。
<img src="$LKEY_ERRIMG_MC$/EI0084.png">
------------------------------
Code: 12056059
Display: 主搬运轨道的换乘传感器异常
Used by: GPX-C
Cause: 1.用于检测换乘过程的传感器未检测出搬运中的电路板,但是用于检测抵达的传感器发生感应了
2.换乘传感器的调试不良
3.抵达传感器误将电路板以外的零部件等(例.电路板挡块)当作电路板发生感应了
Remedy: 1.如果搬运轨道内有电路板,则请对换乘传感器进行调整
2.如果搬运轨道内没有电路板,则请对抵达传感器进行调整
------------------------------
Code: 1205605A
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1205605B
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1205605C
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12056101
Display: Interlock X Tramsfer
Used by:
Cause: Movement of the frame in the X direction may be interfering with the manual cleaning lifter or the
S axis.
Remedy: If it is the manual cleaning lifter, move the frame to the left or to the right and then re-execute
the command. If it is the S axis, move the screen to the left and then re-execute the command.
------------------------------
Code: 12056102
Display: Interlock Screen Lift
Used by:
Cause: The manual cleaning lifter may be interfering with X direction movement of the frame or the S
axis.
Remedy: After moving the manual cleaning lifter to its down position, re-execute the command.
第 583 页
------------------------------
Code: 12056103
Display: Vacuum Holder Too Large
Used by: GP551,GP6
Cause: The size of the board vacuum holder does not match the conveyor width. If the Z-axis is raised
under this condition the conveyor belt will be in danger of being cut.
Remedy: Replace the vacuum holder with one that matches the size of the conveyor width. On the GP6
use the X048 and X049 input signals for verification.
------------------------------
Code: 12056104
Display: 联锁 相机 Z轴
[Interlock Camera Zaxis]
Used by: GP551,GP6,GPX
Cause: 相机与Z轴有可能发生了干涉。在相机移动时Z轴不在待机位置的情况下发生。
Remedy: 请将Z轴移动到待机位置。或者,请确认Z轴待机位置确认传感器的ON/OFF动作。
<img src="$LKEY_ERRIMG_MC$/EI0013.bmp">
------------------------------
Code: 12056105
Display: 联锁 相机 主挡块
[Interlock Camera Main Stopper]
Used by: GP551,GP6,GPX,NXTP
Cause: 安装在相机上的主挡块有可能与其他的部分发生干涉。在下降了主挡块后想要移动相机的情况下发生。
Remedy: 请上升主挡块。或者,请确认MAIN搬运轨道挡块的导入端·退出端的各确认传感器的ON/OFF动作。
<img src="$LKEY_ERRIMG_MC$/12056105.PNG">
------------------------------
Code: 12056106
Display: Interlock Camera Push Plate
Used by: GP551,GP6
Cause: The push plate, attached to the camera, may be damaged in a collision if the push plate is down
and an attempt is made to move the camera.
Remedy: Raise the push plate.Alternatively, check the on/off status of the push plate's up/down position
sensors.
------------------------------
Code: 12056107
Display: InterlockCamera Cleaner
Used by: GP551,GP6
Cause: The camera may collide with the lower cleaner. For GP-5 machines this may occur when the
lower cleaner is not at the origin position. For GP-6 machines, this may occur when the cleaner shift is not
at the retract position.
Remedy: Move the lower cleaner to its origin position (GP-5).For one-sided cleaners, move the cleaner shift
to its retract position (GP-6).Alternatively, check the on/off status of the lower cleaner origin position
sensor, camera and lower cleaner proximity sensor, and the cleaner shift retracted position sensor.
------------------------------
Code: 12056108
Display: Interlock Camera Cleaner Head
Used by: GP551,GP6
Cause: The cleaner head on the cleaner axis may collide with another part. This error occurs if an
attempt is made to move the cleaner axis when the cleaner head is closed.
Remedy: Open the cleaning head. Alternatively, check the on/off status of the cleaner's raised/lowered
sensors (GP-5) or the cleaning head's opened/closed sensors (GP-6).
------------------------------
第 584 页
Code: 12056109
Display: Interlock S axis SGQ Holder
Used by: GP551,GP6
Cause: The squeegee holder on the S-axis may collide with another part. This error occurs if an attempt
is made to move the S-axis when the squeegee holder is down.
Remedy: Raise the squeegee holder. Alternatively, check the on/off status of the squeegee holder's
raised/lowered position sensors.
------------------------------
Code: 1205610A
Display: "Interlock S axis Cleaner Head"
Used by: GP6
Cause: The S-axis cleaner head and another part are in an interference zone with respect to each other,
or are interfering with each other. This error occurs when an attempt is made to move the S-axis while
the cleaner head is closed.
Remedy: Open the cleaner head (set Y020:LW CLNR OPEN or Y021:TP CLNR OPEN to 0). If necessary,
make sure that the lower and upper cleaner head open limit check sensors (X05A:LW CLR OPN CHK and
X07C:TP CLR OPN CHK) are functioning normally.
------------------------------
Code: 1205610B
Display: "Interlock S axis Supply Solder"
Used by: GP551,GP6
Cause: The solder supplier (SSD-axis) may interfere with the S-axis.This error occurs if the S-axis is
moved while the solder supplier (SSD-axis) is not at the escape position.
Remedy: Move the solder supplier (SSD-axis) to the escape position. If necessary, make sure that the
SSD-axis escape position check sensor is functioning normally.
------------------------------
Code: 1205610C
Display: Interlock S axis Cleaner
Used by: GP551,GP6
Cause: The S-axis may collide with the top cleaner. For GP-5 machines, this error occurs when the top
cleaner is not at its origin position and an attempt is made to move the S-axis. For GP-6 machines, this
error occurs when the notch on a cleaner not joined to the S-axis is engaged and the S-axis is moving.
Remedy: Move the top cleaner to its origin position (GP-5). Disengage the cleaner's notch (GP-6).
Alternatively, check the on/off status of the top cleaner's origin position sensor (GP-5) or the lower
cleaner's joining sensor (GP-6).
------------------------------
Code: 1205610D
Display: Interlock Cleaner Z axis
Used by: GP551,GP6
Cause: The lower cleaner and the Z-axis may collide.This error occurs when the Z-axis is not at the
retract position and the cleaner, joined to its driving axis, is in motion.
Remedy: Move the Z-axis to its retract position. Alternatively, check the on/off status of the Z-axis'
retract position sensor.
------------------------------
Code: 1205610E
Display: "Interlock Cleaner Camera"
Used by: GP6
Cause: The camera (X-axis) is in an interference zone with respect to the cleaner, or is interfering with it.
This error occurs if the cleaner (connected to the S-axis) is moved while the camera (X-axis) is not at the
escape position.
Remedy: Move the X-axis to the X-axis camera escape position (the position at which X03D:X ESC POS