Remedy: Check the nozzle. Check that there are no foreign objects in the acquired image. ------------------------------ Code: 1CB02004 Display: 1CB02004 Used by: GL541 Cause: The inclination of the nozzle could not be me…
Display: 1CB01003
Used by: GL541
Cause: The jig cannot be found.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01004
Display: 1CB01004
Used by: GL541
Cause: The inclination of the jig could not be measured.
Remedy: Check that the correct jig is being used.
------------------------------
Code: 1CB01005
Display: 1CB01005
Used by: GL541
Cause: The jig is tilted more than 5 deg..
Remedy: Correct the angle of the jig.
------------------------------
Code: 1CB01006
Display: 1CB01006
Used by: GL541
Cause: The jig edge could not be found.
Remedy: Check that the jig is fully illuminated in the acquired image.
------------------------------
Code: 1CB01101
Display: 1CB01101
Used by: GL541
Cause: The camera type specification is incorrect.
Remedy: Specify the correct camera type.
------------------------------
Code: 1CB01102
Display: 1CB01102
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB02001
Display: 1CB02001
Used by: GL541
Cause: The fluorescent plate could not be found.
Remedy: Check the nozzle. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB02002
Display: 1CB02002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB02003
Display: 1CB02003
Used by: GL541
Cause: The nozzle could not be found.
第 1203 页
Remedy: Check the nozzle. Check that there are no foreign objects in the acquired image.
------------------------------
Code: 1CB02004
Display: 1CB02004
Used by: GL541
Cause: The inclination of the nozzle could not be measured.
Remedy: Check the nozzle. Check that there are no foreign objects in the acquired image.
------------------------------
Code: 1CB02005
Display: 1CB02005
Used by: GL541
Cause: Not presently supported.
Remedy:
------------------------------
Code: 1CB02006
Display: 1CB02006
Used by: GL541
Cause: The nozzle search was not successful.
Remedy: Check that the correct nozzle is being used.
------------------------------
Code: 1CB02201
Display: 1CB02201
Used by: GL541
Cause: The nozzle type specification is incorrect.
Remedy: Specify the correct nozzle type.
------------------------------
Code: 1CB02202
Display: 1CB02202
Used by: GL541
Cause: The nozzle size specification is incorrect.
Remedy: Specify the correct nozzle size.
------------------------------
Code: 1CB02203
Display: 1CB02203
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB03001
Display: 1CB03001
Used by: GL541
Cause: The specified mark size is too small.
Remedy: The minimum mark size is 0.5 mm. Check that the mark data settings in the production
program are correct. If they ARE correct, use a different mark.
------------------------------
Code: 1CB03002
Display: 1CB03002
Used by: GL541
Cause: The specified mark size is too large.
Remedy: The maximum mark size is 3.5 mm. Check that there are no errors in the production program's
mark data. If the production program is correct, use another mark.
第 1204 页
------------------------------
Code: 1CB03004
Display:
Used by: GL541
Cause: Mark data registration failed.
Remedy: Check that the settings in the production program are correct.
------------------------------
Code: 1CB03010
Display: 1CB03010
Used by: GL541,QP132
Cause: The mark could not be found.
Remedy: Check that the production program's mark data is correct. Check that the coordinates of the
mark in the production program are correct.
------------------------------
Code: 1CB03011
Display: 1CB03011
Used by: GL541
Cause: The scan area is too narrow.
Remedy: Set the production program scan area to 1.5 times the mark size. However, the maximum scan
area is 8 mm.
------------------------------
Code: 1CB03012
Display:
Used by: GL541
Cause: There is a large difference between the actual mark size and that in Mark Data.
Remedy: Change the mark size in Mark data.
------------------------------
Code: 1CB03013
Display: 1CB03013
Used by: GL541
Cause: The shape of the mark is ill defined.
Remedy: Unless the mark shape is clearly defined, production cannot begin. Check that there is no dirt
or foreign objects on the mark itself or in the restricted area around the mark.
------------------------------
Code: 1CB03014
Display: 1CB03014
Used by: GL541
Cause: The mark could not be found.
Remedy: Check that the mark is clearly displayed in the image. If the contrast is not clear, adjust the
gain offset for the mark camera.
------------------------------
Code: 1CB04001
Display: 1CB04001
Used by: GL541
Cause: The scan area is larger than the image.
Remedy: The maximum scan area is 8.0 millimeters. Make sure that the mark data description in the
production program is correct.
------------------------------
Code: 1CB04002
Display: 1CB04002
Used by: GL541