Remedy: Ensure that the paired device number is within the range of 000 - 255. ------------------------------ Code: 11E006?? Display: None Used by: CP43,FCP6,CP6M,CP642,CP642M Cause: During use of the pair parts function…
For nozzle numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: Cannot change to the specified nozzle.
Remedy: Do not set nozzle positions in NAT which have not been measured or do not exist.
------------------------------
Code: 11D82301
Display: Nozzle data error
Used by: CP732
Cause: Unable to distinguish the nozzles used for the parts placement.
Remedy: Verify that the nozzle name has been specified in Part Data.
------------------------------
Code: 11E000??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has not been specified in device data.
The pair device number is represented by the question marks.
Remedy: Specify the master device number in sequence data.
------------------------------
Code: 11E001??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has been specified more than once in
device data. The pair device number is represented by the question marks.
Remedy: Specify the master device number only once in sequence data.
------------------------------
Code: 11E002??
Display: Non
Used by: CP642,CP642M
Cause: The associated slave device of the reported pair device has not been specified in device data. The
pair device number is represented by the question marks.
Remedy: Specify the slave device number in sequence data.
------------------------------
Code: 11E003??
Display: Non
Used by: CP642,CP642M
Cause: A slave device associated with a different paired device is present in the slave device loop of the
reported pair device. The pair device number is represented by the question marks.
Remedy: Ensure that the slave device loop contains only slave devices for the associated paired device.
------------------------------
Code: 11E004??
Display: Non
Used by: CP642,CP642M
Cause: The slave device loop for the reported device has been specified more than once. The device
number is represented by the question marks.
Remedy: Ensure that there is only one slave device loop per paired device.
------------------------------
Code: 11E005??
Display: Non
Used by: CP642,CP642M
Cause: The specified paired device number of the reported device is outside the permissible range. The
device number is represented by the question marks.
第 286 页
Remedy: Ensure that the paired device number is within the range of 000 - 255.
------------------------------
Code: 11E006??
Display: None
Used by: CP43,FCP6,CP6M,CP642,CP642M
Cause: During use of the pair parts function, the value specified at the part data item "Empty_cavities" is
outside the acceptable range (CP-6-series), or the specified recovery setting is outside the acceptable range
(CP-43). The question marks (??) represent the device number in hexadecimal format.
Remedy: Set the number of empty cavities within the range of 2 to 10, and set the number of recovery
attempts within the range of 0 to 4.
------------------------------
Code: 12010101
Display: 紧急停止开关 NG EMERGENCY(CP3)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP
1,IP3,QP242,QP201,QP202,QP203,QP132,NP132,NP133,CP-732E,CP-742ME,CP-742E,CP-
752E,GPX,NXTP
Cause: 紧急停止开关被按下了。
Remedy: 请复位紧急停止开关。紧急停止开关带有锁定功能。朝箭头方向(顺时针方向)转动后,锁定就会被解除。
·请按下电源关闭按钮,关闭电源。(CP3)
·请按下电源关闭按钮关闭电源(结束生产时)或者按下复位按钮。(GL)
<img src="$LKEY_ERRIMG_MC$/12010101.PNG">
------------------------------
Code: 12010201
Display: “ 周期停止 ”
Used by: GSP2,GSP3,GSP5,GP2,GP3,IP1,GPX
Cause: 周期停止开关被按下了。
Remedy: 请按下复位按钮。
------------------------------
Code: 12010202
Display: 来自外部输入的停止信号ON
Used by: GPX,NXTP
Cause: 由于来自外部输入的停止信号ON着,因此停止了机器
Remedy: 请确认外部工程是否因错误而停止了。
<img src="$LKEY_ERRIMG_MC$/12010202.PNG">
------------------------------
Code: 12010301
Display:
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,IP1
Cause: The matching production program is finished.
Remedy: None.
------------------------------
Code: 12010401
Display: 完成了生产预定块数(CP5) PRODUCTION COMPLETE(CP3)
完成生产预定块数(GL,GSP2,IP2)
完成生产预定块数。(NP2,QP3)
Used by: CP3,CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,GP551,GP6,IP1,NP2,QP3,
GPX
Cause: 完成了生产预定块数。
Remedy: 请在PROGRAM - QTYCLR 中清除生产块数。(CP3,GL)
第 287 页
请清除生产完成块数。(NP2,QP3)
------------------------------
Code: 12010402
Display: 无
Used by: GSP2,GSP3,GPX,NXTP
Cause: 维修保养计数器到了设定值。 通用计数器递增计数了。 (GPX)
Remedy: 请擦拭网板的反面等维修保养作业,然后重新进入自动运转。(GSP2) 请通过[设定]ー[状态]ー[计数器]进行清
除 (GP6 GP5) 请进行刮刀更换或钢板的更换等必要的对应,将通用计数器清零。(GPX)
<img src="$LKEY_ERRIMG_MC$/12010402.PNG">
------------------------------
Code: 12010403
Display:
Used by: CP3,GL5
Cause: Seq End Stop. Automatic operation is finished.
Remedy: Press the start button and go back into automatic operation.
------------------------------
Code: 12010404
Display: Eject Tray
Used by: IP2
Cause: In a non-matrix tray, parts have run out and the machine stops.
Remedy: Discard the tray.
------------------------------
Code: 12010405
Display: 清洁计数结束
Used by: GPX
Cause: 清洁计数到了设定值。
Remedy: 通过[设定]ー[状态]ー[计数器]进行清除
------------------------------
Code: 12010406
Display: 焊锡供应计数结束
刮刀内焊锡余量不足
Used by: GP551,GPX
Cause: 焊锡供应计数到了设定值。或者,根据余量检测判断出焊锡余量不足。
Remedy: 请进行焊锡供应。请通过[设定]ー[状态]ー[计数器]进行清除。
------------------------------
Code: 12010407
Display: 手动清洁计数结束
Used by: GP551,GPX
Cause: 手动清洁计数到了设定值。
Remedy: 请通过[设定]ー[状态]ー[计数器]进行清除。
------------------------------
Code: 12010408
Display: "Pressure measurement counter limit"
Used by: GP551
Cause: The pressure measurement counter has reached its limit.
Remedy: Enter [SET], [STATUS] , then [COUNTER] to cancel this error.
------------------------------
Code: 12010501
Display: CLEAR OFF COMPLETE
Clear Off Has Been Finished
Clear Off Complete