FUJI错误代码查询.pdf - 第1979页
Display: PST file data type unmatch Used by: Cause: The permanent set table name is not PST. Remedy: At the end of the permanent set table name append the extension .PST. ------------------------------ Code: 21007927 Dis…
Remedy: Reboot the MCS.
------------------------------
Code: 2100791E
Display:
Used by:
Cause: Queuing error.
Remedy: Reboot the MCS.
------------------------------
Code: 2100791F
Display: Queue data moving error
Used by:
Cause: Queue data cannot be moved.
Remedy: Reboot the MCS.
------------------------------
Code: 21007920
Display: Strategy file read error
Used by:
Cause: The strategy file cannot be read.
Remedy: Re-install the strategy file.
------------------------------
Code: 21007921
Display: Make not mark sequence
Used by:
Cause: Error occurred when special sequence created for output program.
Remedy: Reboot the MCS.
------------------------------
Code: 21007922
Display: No entry Input file name
Used by:
Cause: The input file name is not defined.
Remedy: Check the start up parameters and then restart the machine.
------------------------------
Code: 21007923
Display: Output file already exist
Used by:
Cause: The output file name already exists.
Remedy: Change the output file name or select the rewrite mode.
------------------------------
Code: 21007924
Display: Input file data type unmatch
Used by:
Cause: The data type of the input file is different from the production program.
Remedy: Specify the production program's file name.
------------------------------
Code: 21007925
Display: Base program file data type unmatch
Used by:
Cause: The data type of the base program is different from the production program.
Remedy: Specify the production program's file name.
------------------------------
Code: 21007926
第 1978 页
Display: PST file data type unmatch
Used by:
Cause: The permanent set table name is not PST.
Remedy: At the end of the permanent set table name append the extension .PST.
------------------------------
Code: 21007927
Display: Nozzle assignment table file data type unmatch
Used by:
Cause: The nozzle assignment table data type is not NAT.
Remedy: At the end of the nozzle assignment table name in the production program append the extension
.NAT.
------------------------------
Code: 21007928
Display: Input file machine type unmatch
Used by:
Cause: The machine type of the input file is not FCP6.
Remedy: Specify the input file as an FCP6 production program.
------------------------------
Code: 21007929
Display: Base program file machine type unmatch
Used by:
Cause: The machine type of the base program is not FCP6.
Remedy: Specify the input file as an FCP6 production program.
------------------------------
Code: 2100792A
Display: Nozzle assignment table file machine type unmatch
Used by:
Cause: The machine type of the nozzle assignment table is not FCP6.
Remedy: Specify the nozzle assignment table in the production program as an FCP6 nozzle assignment
table.
------------------------------
Code: 2100792B
Display: Input file expand error
Used by:
Cause: An error occurred while the input file was being expanded.
Remedy: Press Ctrl + E to check the error.
------------------------------
Code: 2100792C
Display: Base program file expand error
Used by:
Cause: An error occurred while the base program was being expanded.
Remedy: Press Ctrl + E to check the error.
------------------------------
Code: 2100792D
Display: Not get Part data file name
Used by:
Cause: The Part data name could not be obtained from the input file.
Remedy: Register the Part data name in the program's device data.
------------------------------
Code: 2100792E
Display: Not get Nozzle assignment file name
第 1979 页
Used by:
Cause: The nozzle assignment file name has not been entered in the input program.
Remedy: Using the editor enter the nozzle assignment file name in the program.
------------------------------
Code: 2100792F
Display: Not get nozzle size
Used by:
Cause: An error occurred while obtaining the nozzle size for each part from Part data and the nozzle
assignment table.
Remedy: Using the editor edit the Part data and nozzle assignment table to ensure that the Part data
nozzle sizes are in the nozzle assignment table.
------------------------------
Code: 21007930
Display: Same deviice comment entry in PST file.
Used by:
Cause: In the PST file there is a device comment with the same name.
Remedy: Edit the permanent set table using the editor command to ensure that there are no duplicated
device comment entries.
------------------------------
Code: 21007931
Display: No entry Cartridge name.
Used by:
Cause: The feeder name is not in the permanent set table.
Remedy: Enter the feeder name in the permanent set table.
------------------------------
Code: 21007932
Display: Abnormal device number in PST file.
Used by:
Cause: There is an abnormal device number in the permanent set table (PST).
Remedy: Edit the PST using the editor command to ensure that the device numbers in the PST are less
than the maximum (140).
------------------------------
Code: 21007933
Display: Abnormal device comment in PST file.
Used by:
Cause: There is an abnormal device comment in the permanent set table.(PST)
Remedy: Edit the PST using the editor command to ensure that all device comments have been entered.
------------------------------
Code: 21007934
Display: Position already used.
Used by:
Cause: A position specified in the permanent set table (PST) is already in use.
Remedy: Edit the PST to ensure that no device numbers are duplicated.
------------------------------
Code: 21007935
Display: Not generate cartridge name.
Used by:
Cause: An error occurred when the feeder names were automatically generated.
Remedy: Edit the Part data.
------------------------------
Code: 21007936
第 1980 页