FUJI错误代码查询.pdf - 第572页
Remedy: Check that a back-up pin is not contacting parts on the lower surface of the board. Unload the board if parts are being contacted, otherwise resumu operation after adjusting the position of the board. -----------…
P132,CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 基准定位点的读取结果在程序的"mark_area_tolerance"中所设定的范围外。有可能发生定位点的误识别。
Remedy: 请确认基准定位点的读取状态。
请确认"mark_area_tolerance"的值是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12055004.PNG">
------------------------------
Code: 12055005
Display: 定位点检查错误
在间距检查中超出了区域公差值。
Used by: CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GP551,GP6,IP1,IP2,IP3,QP242,QP201,QP202,QP203,Q
P132,CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 基准定位点的读取结果在程序的"mark_pitch_tolerance"中所设定的范围外。有可能发生定位点的误识别。
Remedy: 请确认基准定位点的读取状态。
请确认"mark_pitch_tolerance"的值是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12055005.PNG">
------------------------------
Code: 12055006
Display: "Vision processing system alarm" (CP6)
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,QP242,QP201,QP202,QP203,NP2,QP3
Cause: This is a timeout error. The results of vision processing have not been returned. There is a
problem in the vision processing system.
Remedy: Restart the machine. Contact Fuji if this problem occurs even after the machine is restarted.
------------------------------
Code: 12055007
Display: "Vision processing command timeout"
Used by: QP132,NP2,QP3
Cause: This is a timeout error. The results of vision processing registration have not been returned.
There is a problem in the vision processing system.
Remedy: Restart the machine.
------------------------------
Code: 12055008
Display: 12055008
Used by: QP132
Cause: After reading the fiducial mark, the board was judged to be misaligned by more than +-1 mm in
the x direction (FQP1).Depending on the PMC stroke, placement may not be possible.
Remedy: Adjust the board position so that its offset is within the tolerance range.
------------------------------
Code: 12055009
Display: Mark offset too large.
Used by: QP132
Cause: The resulting fiducial mark reading shows a mark offset in the X or Y-direction being greater than
+-3 mm.
Remedy: If may not be possible for the PMC to carry out the placement stroke.Adjust the position of the
board so that the board offset is within range.
------------------------------
Code: 12055011
Display: Mark Check Error:Seq_No. Check board condition Excessive mark misalignment. Adjust board
and restart, or unload the board.
Used by: CP643,CP7series,QPseries,NPseries,GL541
Cause: Excessive mark misalignment. The clamped board is misaligned in excess of the acceptable limit.
第 571 页
Remedy: Check that a back-up pin is not contacting parts on the lower surface of the board. Unload the
board if parts are being contacted, otherwise resumu operation after adjusting the position of the board.
------------------------------
Code: 12055012
Display: Vision processing has been aborted.
Used by: NP2,QP3
Cause: The execution of vision processing has been aborted.
Remedy: Restart the machine. Contact Fuji if this problem occurs even after the machine is restarted.
------------------------------
Code: 12055013
Display: Data error!
Used by: NP2,QP3
Cause: Internal data error!
Remedy: Restart the machine.
------------------------------
Code: 12055014
Display: Pre-allocated sequence error!
Used by: NP2,QP3
Cause: Pre-allocated sequence error!
Remedy: Check the production program, unload the PCB and restart the machine.
------------------------------
Code: 12055015
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot create pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055016
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot open pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055017
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot close pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055018
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot change the name of the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055019
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot write to the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
第 572 页
Code: 1205501A
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot read the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 1205501B
Display: 没有进行周期自动补正的有效的吸嘴。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 没有进行周期自动补正的有效的吸嘴。
Remedy: 请安装能够进行周期自动补正的吸嘴。
------------------------------
Code: 12055026
Display: 周期自动补正超过了补正容许范围。
请用测定回转中心指令进行测定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 周期自动补正值超过了补正公差值。
Remedy: 请用测定回转中心指令进行测定。
------------------------------
Code: 12055027
Display: Double placement error
Used by: QP3
Cause: A sequence that has already been completed has been specified. Parts may be placed on top of
one another.
Remedy: Acquire a trace and unload the panel from the machine.
------------------------------
Code: 12055028
Display: 周期自动补正的测定结果超过极限。
Used by: XP142,XP242
Cause: 周期自动补正的测定结果超过极限。
Remedy: 请重新检查极限的下限值和上限值。
------------------------------
Code: 12056001
Display: "Nozzle type alarm" (CP4), "ST17 nozzle type detection error: HEAD?"
(CP6)
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: When this error occurs on a CP4, none of the nozzle type check sensors has turned on.On a CP6,
a nozzle type check (ST17) indicated a nozzle type other than 1 through 6.
Remedy: On a CP4, adjust ST10 and ST11 so that the sensors can detect the nozzle type. If this error
seems to occur with no specific nozzle on a CP6, check the adjustment of the nozzle type detection sensor.
If it tends to occur with a specific nozzle, inspect the nozzle detection locations for the specified head.
------------------------------
Code: 12056002
Display: "Nozzle change error"
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The results of a nozzle change check (ST11) indicate a different nozzle type than that remembered
by the machine.On the CP6, this error is reported when a nozzle type check (ST19) performed after a
nozzle change (ST18) indicates a nozzle type other than 1 through 6. This error may also occur if the
nozzle has been changed to a type other than the targeted type.
Remedy: Check the holder, or adjust the nozzle type check sensor.If this error seems to occur with no
specific nozzles on a CP6, check the adjustment of the nozzle type detection sensor. If it tends to occur
第 573 页