FUJI错误代码查询.pdf - 第1445页

Display: Used by: Cause: A lead could not be found. Remedy: Check the lead width, the part shape, and the conditions under which the image is taken. ------------------------------ Code: 1D14400F Display: Used by: Cause: …

100%1 / 5282
Remedy: Check Part data.
------------------------------
Code: 1D140002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D144001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D144007
Display:
Used by:
Cause: There are 2~4 leads more than set in Part data.
Remedy: Check the setting in Part data.
------------------------------
Code: 1D144009
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400A
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400B
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400C
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400D
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D14400E
第 1444 页
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400F
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D144010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D144011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D144012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D144013
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D148002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D148100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D148110
第 1445 页
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D148111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D148112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D148113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D148114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D148115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D148120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D148121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D148122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
第 1446 页