FUJI错误代码查询.pdf - 第1967页
Display: CRT event link error Used by: Cause: The CRT event could not be linked. Remedy: Re-boot MCS. ------------------------------ Code: 21007803 Display: Read pipe create error Used by: Cause: The read pipe could not …
Code: 21007753
Display:
Used by:
Cause: The environment file could not be read.
Remedy: Re-install the software.
------------------------------
Code: 21007754
Display: different device type arranged at same stn.
Used by:
Cause: When device data was rearranged, the largest station returned to station 1.
Remedy: Reduce the number of next devices in the input program and reexecute the function.
------------------------------
Code: 21007755
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007756
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 21007757
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007758
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007800
Display:
Used by:
Cause: There was an illegal parameter in the startup option (+wtlb).
Remedy: Check the startup option and restart.
------------------------------
Code: 21007801
Display: Message file read error
Used by:
Cause: The message file could not be read.
Remedy: Re-install MCS.
------------------------------
Code: 21007802
第 1966 页
Display: CRT event link error
Used by:
Cause: The CRT event could not be linked.
Remedy: Re-boot MCS.
------------------------------
Code: 21007803
Display: Read pipe create error
Used by:
Cause: The read pipe could not be created.
Remedy: Re-boot MCS.
------------------------------
Code: 21007804
Display: Write pipe create error
Used by:
Cause: The write pipe could not be created.
Remedy: Re-boot MCS.
------------------------------
Code: 21007805
Display: Illegal parameter
Used by:
Cause: The parameters are illegal.
Remedy: Check the startup parameters and re-boot.
------------------------------
Code: 21007806
Display: No entry Input file name
Used by:
Cause: The input program name has not been registered.
Remedy: Register the input program name.
------------------------------
Code: 21007807
Display: No entry Nozzle file name
Used by:
Cause: The nozzle information file name has not been registered.
Remedy: Register the nozzle information file name.
------------------------------
Code: 21007808
Display: No entry Tray file name
Used by:
Cause: The tray information file name has not been registered.
Remedy: Register the tray information file name.
------------------------------
Code: 21007809
Display: Output file already exist
Used by:
Cause: The output file already exists.
Remedy: Either specify rewrite or change the output filename.
------------------------------
Code: 2100780A
Display: Input file name is too long
Used by:
Cause: The input filename is too long.
第 1967 页
Remedy: The filename must be 23 characters or less.
------------------------------
Code: 2100780B
Display: Output file name is too long
Used by:
Cause: The output filename is too long.
Remedy: The filename must be 23 characters or less.
------------------------------
Code: 2100780C
Display: PT file name is too long
Used by:
Cause: The PT filename is too long.
Remedy: The filename must be 23 characters or less.
------------------------------
Code: 2100780D
Display: Nozzle file name is too long
Used by:
Cause: The nozzle information filename is too long.
Remedy: The filename must be 23 characters or less.
------------------------------
Code: 2100780E
Display: Tray file name is too long
Used by:
Cause: The tray filename is too long.
Remedy: The filename must be 23 characters or less.
------------------------------
Code: 2100780F
Display: Input file open error
Used by:
Cause: Input file open error.
Remedy: Edit the input program at the editor.
------------------------------
Code: 21007810
Display: Input file read error
Used by:
Cause: Input file read error.
Remedy: Edit the input program at the editor.
------------------------------
Code: 21007811
Display: Input file data type unmatch
Used by:
Cause: The input program data type is not a program.
Remedy: Specify an input program in the program file.
------------------------------
Code: 21007812
Display: Input file machine type unmatch
Used by:
Cause: A non-IP3 program was specified for optimization.
Remedy: Specify an IP3 program.
------------------------------
Code: 21007813
第 1968 页