FUJI错误代码查询.pdf - 第1128页
Used by: CP-732E, CP-742ME, CP-742E, CP-752E Cause: XY-table up/down travel was not completed within the prescribed period of time. Remedy: Check for objects which may be interfering with XY-table up/down travel. -------…
Code: 15040326
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the first panel failed to
switch on even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040327
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the first panel failed to switch
off even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040328
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch on even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 15040329
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side clamp limit signal for the second panel failed to
switch off even though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032A
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side unclamp limit signal failed to switch on even
though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032B
Display: XY-table unclamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's adjustable rail side clamp limit signal failed to switch off even
though a panel unclamp command was executed.
Remedy: Verify that the XY-table is unclamping the panel correctly.
------------------------------
Code: 1504032D
Display: XY-table clamping error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table panel clamper's fixed rail side unclamp limit signal for the second panel failed to
switch on even though a panel clamp command was executed.
Remedy: Verify that the XY-table is clamping the panel correctly.
------------------------------
Code: 1504032E
Display: XY-table up/down travel time-up.
第 1127 页
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table up/down travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table up/down travel.
------------------------------
Code: 15040330
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch on at one of the following:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040331
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor was not triggered at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is clamped properly. If clamped properly but this error occurs anyway,
adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a sensor
wiring problem or a sensor failure.
------------------------------
Code: 15040332
Display: XY-table unclamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: An unclamp limit sensor failed to switch on at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the unclamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040333
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A clamp limit sensor failed to switch off at one of the following locations:
qd The XY-table's first panel clamper at the fixed-rail side
qd The XY-tables second panel clamper at the fixed-rail side
qd The clamper at the adjustable-rail side
Remedy: Check to see if the panel is properly unclamped. If properly unclamped but this error occurs
anyway, adjust the mounting position of the clamp limit sensor. If the error still occurs, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 15040334
Display: XY-table clamp limit error.
Used by: CP-732E, CP-742ME, CP-742E
第 1128 页
Cause: Only the second panel is present.
Remedy: Check to see if the first panel is being conveyed properly.
------------------------------
Code: 15040335
Display: Main conveyor unclamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor unclamp limit sensor input error.
Remedy: Check to see if the sensors (X061, X062, X064) are operating properly.
------------------------------
Code: 15040336
Display: Main conveyor clamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit sensor input error.
Remedy: Check to see if the sensors (X05F, X060, X063) are operating properly.
------------------------------
Code: 15040337
Display: Main conveyor clamp limit and unclamp limit sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit and unclamp limit sensor logic error.
Remedy: Verify that all sensors (X05F to X064) are operating properly.
------------------------------
Code: 15040338
Display: Loading position sensor error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Logic check error at loading position sensors. The sensors at both the IN and OUT sides are on.
Remedy: Verify that the sensors (X0BF to X0DA) are operating properly.
------------------------------
Code: 15040339
Display: Main lifter sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The main lifter UP sensor and the main lifter OT sensor are both on.
Remedy: Verify that the sensors (X05C to X05E) are operating properly.
------------------------------
Code: 1504033A
Display: Table height sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A logic error occurred at the table height sensor when placing parts. The DOWN limit sensor
switched off.
Remedy: Verify that the table height sensor is operating properly.
------------------------------
Code: 1504033B
Display: XY-table travel time-up.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table travel.
------------------------------
Code: 1504033C
Display: Loader unit error
Used by: NP2,QP3
Cause: Error occurred between the machine and the motor control panel.
Remedy: Restart the machine.