Code: 11010108 Display: Program SX+ Used by: IP1,QP242,QP201,QP202,QP203 Cause: The target value in the +SX direction set in the production program is out of range. Remedy: Make the +SX value set in the production progra…
Code: 11010101
Display: Program 0011
Program NG 0011
Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The referent mark number sequence set in the mount sequences (application sequence, print
sequence) cannot be found.
Remedy: Check MCS. If only one referent mark is to be used, enter the same number for main mark and
sub mark. If the sub mark is set to zero this error will occur. Also check the displayed sequence mark
data.
------------------------------
Code: 11010102
Display: Program 0002
Program NG 0002
Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203
Cause: There is not a mark read sequence at the mark number set in the mount sequences (application
sequence, print sequence).
Remedy: Checking the data in MCS does not often produce results. It is thought that the data may be
changed in transmission. Therefore, check the data and transmit the program.
------------------------------
Code: 11010103
Display: Program 0010
Used by: GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,QP242,QP201,QP202,QP203
Cause: On the GL, the mark read sequence was not executed (or an error occurred) but the machine
attempted to execute the mount sequences (application sequence, print sequence).
Remedy: Move the mark read sequence in front of any mount sequences in the production program.
------------------------------
Code: 11010104
Display: Program X+
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: On the GSP, IP1 or GL, the target position set for the X axis in the production program is out of
range.
Remedy: Make the +X value in the production program's mark read sequence smaller.
------------------------------
Code: 11010105
Display: Program X-
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -X direction set in the production program is out of range.
Remedy: Make the -X value in the production program (mark read sequence) larger.
------------------------------
Code: 11010106
Display: Program Y+
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +Y direction set in the production program is out of range.
Remedy: Make the +Y value set in the production program (mark read sequence) smaller.
------------------------------
Code: 11010107
Display: Program Y-
Used by: GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -Y direction set in the production program is out of range.
Remedy: Make the -Y value set in the production program (mark read sequence) larger.
------------------------------
第 2 页
Code: 11010108
Display: Program SX+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SX direction set in the production program is out of range.
Remedy: Make the +SX value set in the production program (mark read sequence) smaller.
------------------------------
Code: 11010109
Display: Program SX-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SX direction set in the production program is out of range.
Remedy: Make the -SX value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010A
Display: Program SY+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SY direction set in the production program is out of range.
Remedy: Make the +SY value set in the production program (mark read sequence) smaller.
------------------------------
Code: 1101010B
Display: Program SY-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SY direction set in the production program is out of range.
Remedy: Make the -SY value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010C
Display: Program S+
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the +X direction.
Remedy: Make the +X value set in the print sequence of the production program smaller.
------------------------------
Code: 1101010D
Display: Program S-
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the -X direction.
Remedy: Make the -X value set in the print sequence of the production program larger.
------------------------------
Code: 1101010E
Display: Program 0001
Used by: GL2,QP242,QP201,QP202,QP203
Cause: The head number has not been entered in sequence data.
Remedy: Check the "H" heading in the production program.
------------------------------
Code: 1101010F
Display: Program 0020
Used by: GL2,GL541,QP242,QP201,QP202,QP203
Cause: G data is not entered in the application sequence.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010110
Display:
Used by: QP242,QP201,QP202,QP203
第 3 页
Cause: The placing sequence does not exist in the production program
(sequence data: N_Data).
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010111
Display: "Specified Position Out Of Range [MX |MYL |MYR |S |SSD |X |Y |Z ]
[+|-]"
Used by: GSP2,GSP3,GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs upon servo axis activation when the specified servo axis destination value has
exceeded the possible movement range.
Remedy: Make sure that the following values are within the normal range: Proper data and production
program data values related to the command or action being executed when the error occurred.
------------------------------
Code: 11010112
Display: "Specified Position Out Of Range Printing [+|-]"
Used by: GSP2,GSP3,GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when the machine tries to move the S-axis to a destination value beyond the
printable range while the near or far squeegee holder is down.
Remedy: Make sure that the following values are within the normal range: Proper data and production
program data values related to the S-axis command or action being executed when the error occurred.
------------------------------
Code: 11010113
Display: "Specified Position Out Of Range Cleaner [+|-]"
Used by: GP6,QP242,QP201,QP202,QP203
Cause: The specified cleaning area (during cleaning) or a specified travel target position (when the cleaner
head is closed) is out of the cleaning range.
Remedy: Designate a cleaning area which is within the cleaner's travel range, or verify that the Proper
Data or production program values related to the cleaner head (GP6 double-side cleaner: S-axis, GP6 one-
side cleaner: Y-axis, GP5: CX-axis) are within the correct range.
------------------------------
Code: 11010121
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 1 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010122
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 2 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------
Code: 11010123
Display: The number of sequences is outside the permissible range.
Used by: QP242
Cause: The number of sequences for module 3 is outside the permissible range. It is not possible to
execute more than 1000 sequences at a single module.
Remedy: Reduce the number of sequences.
------------------------------