Code: 110823D0 Display: Y-Axis Not in Retract Pos Used by: MTU4 Cause: The Y axis speed reduction sensor was not on when the T axis attempted to move. Remedy: Check the Y axis speed reduction sensor and the dog. Also che…

100%1 / 5282
0.
------------------------------
Code: 11082360
Display: Waffle Tray Overloaded Remove Part
Used by: MTU4
Cause: Too many waffle trays have been stacked up.
Remedy: Remove the overstacked waffle trays.
------------------------------
Code: 11082370
Display: Reject Tray Box Full
Used by: MTU4
Cause: This error occurs when discarded trays accumulate, causing the sensor beam to be cut for a
continued period of time.
Remedy: Remove the accumulated trays. Check the adjustment of the sensors. Check that there are no
other objects in the tray area.
------------------------------
Code: 11082380
Display: Tray Reject Error
Used by: MTU4
Cause: This error occurs when a tray which is to be ejected is released at the eject position but the eject
sensor does not detect the falling tray.
Remedy: If the tray cannot be picked up, adjust the tray pick up point set in part data's Tray_pickup_pnt
and check that the tray can be picked up. Furthermore, if this error occurs even when the tray is picked
up, check the sensor.
------------------------------
Code: 11082390
Display: Tray Plate Setting Error
Used by: MTU4
Cause: The tray plate set sensor was activated while the T axis was moving.
Remedy: Check that the tray plate door is not open and that the tray plate is firmly positioned.
------------------------------
Code: 110823A0
Display: No Tray
Used by: MTU4
Cause: There are no trays but manual tray positioning was attempted.
Remedy: Supply trays.
------------------------------
Code: 110823B0
Display: Tray Space Chk Sens. Not ON
Used by: MTU4
Cause: The robot safety sensor was not on when the Y axis moved to pick up a tray part or to eject a
tray.
Remedy: Check the robot safety sensor and the dog. Also check that a suitable value is entered for the
MTU Proper data item Origin_Position_T0 to ensure that the T axis origin is at the correct position.
------------------------------
Code: 110823C0
Display: Tray Number Internal Error
Used by: MTU3,MTU4,MTU
Cause: During tray positioning, an abnormal tray number was detected.
Remedy: Initialize the memory.
------------------------------
第 221 页
Code: 110823D0
Display: Y-Axis Not in Retract Pos
Used by: MTU4
Cause: The Y axis speed reduction sensor was not on when the T axis attempted to move.
Remedy: Check the Y axis speed reduction sensor and the dog. Also check that a suitable value has been
entered for the MTU4 Proper data item Carrier_Position_SY.
------------------------------
Code: 11082400
Display: 11082400
Used by: MTU3,MTU5
Cause: An attempt was made to advance the Y axis to the Z axis interlock position.
Remedy: Check the Z axis interlock sensor and dog.
------------------------------
Code: 11082410
Display: 11082410
Used by: MTU3,MTU5
Cause: When the sub-nozzle placed a part on the conveyor, the nozzle's vacuum sensor judged that there
was still a part on the nozzle.
Remedy: Check the mouth of the nozzle, the air supply, the sensor etc.
------------------------------
Code: 11082420
Display: 11082420
Used by: MTU3,MTU5
Cause: A tray part picked up by the sub-nozzle was dropped before it was placed on the conveyor.
Remedy: Check the mouth of the nozzle, the air supply system etc. Also check that suitable values have
been entered in part data and for the Proper data item Tray_Pos_T.
------------------------------
Code: 11082421
Display: 11082421
Used by: MTU3,MTU5
Cause: When an attempt was made to deliver a part to the IP machine, the conveyor parts check sensor
judged that there was no part on the conveyor.
Remedy: Check whether the part fell off the conveyor during delivery.
------------------------------
Code: 11082430
Display: 11082430
Used by: MTU3,MTU5
Cause: When the X and Z axes attempted to move during automatic operation, the Y axis retract sensor
was not on.
Remedy: Check that a suitable value has been entered for the Proper data item Interlock_SY.
Furthermore, adjust the sensor and the dog.
------------------------------
Code: 11082440
Display: 11082440
Used by: MTU3,MTU5
Cause: The Z axis retract sensor was off when the sub-nozzle shaft retracted during automatic operation.
Remedy: Check that the nozzle retracts correctly. Also check that the sensor is functioning correctly.
------------------------------
Code: 11082450
Display: 11082450
Used by: MTU3,MTU5
第 222 页
Cause: According to the conveyor end sensor there is a part on the conveyor.
Remedy: Due to a pickup mistake made by the IP machine, there is an unnecessary part on the conveyor.
In this case, remove the part.
------------------------------
Code: 11082460
Display: 11082460
Used by: MTU3,MTU5
Cause: The parts supply door at the back of the MTU is open.
Remedy: Close the door. In addition, check that the door is properly positioned.
------------------------------
Code: 11082490
Display: 11082490
Used by: MTU3,MTU5
Cause: The tray set sensor is off. A tray may have stopped mid-way through being ejected.
Remedy: Check that all of the trays in the column at the nozzle position where the error occurred are
correctly positioned. In addition, check that the sensor positions match the tray positions.
------------------------------
Code: 110824A0
Display: 110824A0
Used by: MTU3,MTU5
Cause: There is an unexpected part on the sub-nozzle. The part may have been placed there by the
operator.
Remedy: Remove the part on the sub-nozzle.
------------------------------
Code: 11083200
Display: Sequence number is out of range.
Used by: MTU4
Details: The sequence number is out of the valid range.
Cause:
Remedy: Ensure that the sequence number is between 1 and 4999.
------------------------------
Code: 11083210
Display: Device number is out of range.
Used by: MTU4
Details: The device number for the tray part is out of the valid range.
Cause:
Remedy: Ensure that the first digit in the device number is 1 for a tray unit on the right side, or 3 for a
tray unit on the left side. The second digit in the device number must be between 0 to 9, and the last digit
in the device number must be between 1 to 4.
------------------------------
Code: 11083220
Display: Terminate setting out of range.
Used by: MTU4
Details: A setting for a terminate sequence is out of the valid range.
Cause:
Remedy: The setting for the terminate sequence must either be ˇˇ(for a non terminate sequence) or
ˇˇ(for a terminate sequence).
------------------------------
Code: 110832F0
Display: Sequence Data Device Number Out of Range
Used by: MTU3,MTU4,MTU5