Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E Cause: The maintenance key was turned ON, but the Maintenance Mode panel is not open so the Maintenance Mode cannot be activated. Remedy: Open the Maintenance Mo…
Code: 1206104A
Display: NY-axis start processing error
Used by: CP-8Series
Cause: An NY-axis start signal was output while in error status.
Remedy: Correct the cause of the error, and push READY ON.
------------------------------
Code: 1206104C
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the plus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 1206104D
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the minus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 12061050
Display: FQ offset amount error
Used by: CP-732E, CP-742ME, CP-742E, CP-733E, CP-743ME, CP-743E
Cause: The FQ rotation cannot be performed within the permissible cycle time as the Q-direction vision
processing offset amount is too large.
Remedy: Please check the pick-up status of the part.As a preliminary measure, set a value of "20" for the
"Pickup Tolerance" item in part data.
------------------------------
Code: 12061052
Display: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Used by: CP43,CP6,CP6M,CP65,CP642,CP642M,CP643,CP643M
Cause: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Remedy: Check the error details at the Fujitrax computer and take necessary measures.
------------------------------
Code: 12061053
Display: Nozzle center unmeasured
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: Nozzle holder center measurement has not been performed for the holder displayed in the
parameter section after performing part camera calibration data measurement or (X0,Y0) calibration data
measurement. There is a possibility of a drop in accuracy.
Remedy: Attach a 1.0~2.5mm nozzle and perform nozzle holder center measurement.
------------------------------
Code: 12061054
Display: Maintenance key is OFF
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: The Maintenance Mode cannot be used because the maintenance key is switched OFF.
Remedy: Switch the maintenance key ON, or exit from the Maintenance Mode panel and push the READY
ON button.
------------------------------
Code: 12061055
Display: Maintenance Mode unavailable
第 606 页
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: The maintenance key was turned ON, but the Maintenance Mode panel is not open so the
Maintenance Mode cannot be activated.
Remedy: Open the Maintenance Mode panel, or switch the maintenance mode key OFF and push the
READY ON button.
------------------------------
Code: 12062001
Display: ERROR CV parts Full
Used by: IP1,IP2
Cause: The rejected parts conveyor belts has too many parts on it, the sensor is on, and more parts
cannot be rejected.
Remedy: Remove the parts from the conveyor (IP). Also, adjust the sensor position and sensitivity.
------------------------------
Code: 12062002
Display: RESCAN ERROR
Used by: IP1,IP2
Cause: Rescanning was done 3 times but the part was still not at the angle specified in Part data.
Remedy: Check the part supply, and check Part data.
------------------------------
Code: 12062003
Display: Sub Nozzle
Used by: IP1
Cause: The sub-nozzle moved down while the sub-robot was in motion (IP).
Remedy: Check the air pressure and the sub-nozzle's raised position.
------------------------------
Code: 12062004
Display: Please use new NOZZLE CHANGE
Used by:
Cause: This occurs on versions using v2.30 and later ROM chips during nozzle change (IP). Nozzle
change on these versions are not supported.
Remedy: Use the new type. Refer to the "Appendix, Part 1.2" 69 : Machine Status B of the IP manual.
------------------------------
Code: 12062005
Display: Error L(R) Tray original
Used by: IP1
Cause: The I/O setting RT_READY/LT_READY is off(IP, IP2).
Remedy: Inch the tray to the sensor where the sensor should be on and check the I/O display.
Alternately, with the servo lock cancelled, and the SX zero setting dog sensor and SX Interference check
dog sensor on, press [UNIT] and [D] to return to the original position. Note that when the dog has been
removed, and the tray is down below the point where it would be after zero setting, do not use the [D]
command key.
------------------------------
Code: 12062006
Display: Error: Sub Robot original
Used by: IP1
Cause: The sub-robot is not in its original position (IP, IP2).
Remedy: Inch the sub-robot to its original position. This is the position where the SX zero setting dog
sensor and SX Interference check dog sensor are on.
------------------------------
Code: 12062007
Display: L(R) TRAY SET ERROR
第 607 页
Tray drawer not set IP2
Used by: IP1
Cause: The tray drawer is open.
Remedy: Either the left or right tray set sensor is on. Close the tray drawers by hand.
------------------------------
Code: 12062008
Display: No Nozzle(IP,IP2)
Nozzle selection error!(NP2,QP3)
Used by: IP1,IP2,NP2,QP3
Cause: There is no nozzle in the position from which nozzle change is to be carried out (IP, IP2).
The required nozzle is not present in the nozzle station.(NP2,QP3)
Remedy: Set a nozzle in that position. Alternately, check the sensor sensitivity level.
Check the production program and nozzle memory.(NP2,QP3)
------------------------------
Code: 12062009
Display: Error: Duplex Nozzle
Used by: IP1,IP2
Cause: The operator has attempted to eject the nozzle, but there is already a nozzle at the place where
the nozzle was to have been ejected (IP, IP2).
Remedy: When the machine memory does not match actual conditions, either change the nozzle by hand
or perform a nozzle check. When there is no nozzle in the position in question, adjust the sensor.
------------------------------
Code: 1206200A
Display:
Used by: IP1
Cause: Not in use. The original 1206200A message has been moved to 1206200C.
Remedy: None.
------------------------------
Code: 1206200B
Display: Check Nozzle
Used by: IP2
Cause: When performing zero setting, the nozzle in the machine memory has been placed onto the block
(IP). Both the L and LL nozzles are not at their nozzle stations, and after nozzle check the nozzle cannot
be cancelled (IP2).
Remedy: Check the sensors at the nozzle stations. If the nozzle has not been picked, perform a nozzle
check (IP). Place the nozzles at the nozzle station (IP2).
------------------------------
Code: 1206200C
Display: NOZZLE SIZE CHECK ERROR
Used by: IP1
Cause: During nozzle check an irrelevant nozzle has been indicated.
Remedy: Adjust the sensor, and perform nozzle check.
------------------------------
Code: 1206200D
Display: NOZZLE CHECK ERROR
Used by: IP1,IP3
Cause: An error occurs in the middle of nozzle check.
Remedy: Perform nozzle check again.
------------------------------
Code: 1206200E
Display: Nozzle Change error
第 608 页