FUJI错误代码查询.pdf - 第2137页

Remedy: Specify 2 or more lines for the "Element"setting. ------------------------------ Code: 2300E589 Display: 2 or more Element lines are required for Vision Type 124. Used by: Cause: For Vision Type 124,vis…

100%1 / 5282
more.
------------------------------
Code: 2300E583
Display: The specified part size exceeds the scanning range (Body Length (X):5 mm or less, Body Width
(Y):4 mm or less) that can be handled by the camera for Vision Type 10.
Used by:
Cause: The maximum part dimensions that may be specified when using vision type 10 are 5 mm for the
body length (X) and 4 mm for the body width (Y). If the specified part size exceeds these dimenhe part
may not be found or accuracy may be negatively affected.
Remedy: When using vision type 10, only use parts with maximum dimensions of 5 mm for the body
length (X), and 4 mm for the body width (Y). For larger parts, create the part data using vision type 18.
------------------------------
Code: 2300E584
Display: For Vision Type 124, the [Element] setting must occupy either 2 or 4 lines.
Used by:
Cause: For Vision Type 124, vision processing is only possible when the "Element" setting occupies either
2 or 4 lines.
Remedy: Specify either 2 or 4 lines for the "Element" setting.
------------------------------
Code: 2300E585
Display: For Vision Type 180, the total number of leads in [Lead Quantity] for the entire element must be
2, 3, or 4
Used by:
Cause: For Vision Type 180, the total number of leads in "Lead Quantity" for the entire element must be
2, 3, or 4.
Remedy: When using Vision Type 180, set the values for "Lead Quantity" so that the sum of all leads for
the element equals 2, 3, or 4.
------------------------------
Code: 2300E586
Display: 5 or more leads do not exist, or the part exceeds the scan range that can be handled by the
camera.
Used by:
Cause: 5 or more leads are required. Where 5 or more leads exist, and the part is picked up at the
revolver center, the part exceeds the scan range that can be handled by the camera.
Remedy: Create the part data using vision type 18 or 20.
------------------------------
Code: 2300E587
Display: The settings at Scan Area X and Scan Area Y are outside the range that can be handled by the
Front(Rear) camera (short side: **.***; long side: **.***).
Used by:
Cause: The settings at "Scan Area X" and "Scan Area Y" are outside the range that can be handled by the
Front(Rear) camera (short side: %.3f; long side: %.3f).
Remedy: Compare "Scan Area X" with "Scan Area Y." The one with the lower value should be set to be
shorter than the short side of the field of view, and the one with the higher value should be set to be
shorter than the long side.
------------------------------
Code: 2300E588
Display: 2 or more Element lines are required for Vision Type 20.
Used by:
Cause: For Vision Type 20,vision processing is only possible when the "Element"setting occupies 2 or
more lines.
第 2136 页
Remedy: Specify 2 or more lines for the "Element"setting.
------------------------------
Code: 2300E589
Display: 2 or more Element lines are required for Vision Type 124.
Used by:
Cause: For Vision Type 124,vision processing is only possible when the "Element"setting occupies 2 or
more lines.
Remedy: Specify 2 or more lines for the "Element"setting.
------------------------------
Code: 2300E590
Display: The Element Result setting is Matrix for the first line for a part with Vision Type 230 or 231.
Used by:
Cause: There is an error in the element settings.The Element Result setting is Matrix for the first line for
a part with Vision Type 230 or 231.
Remedy: Change the Element Result setting to Inspect for the first line for Vision Type 230 or 231.
------------------------------
Code: 2300E591
Display: The Element Result setting is Matrix for two consecutive lines for a part with Vision Type 230 or
231.
Used by:
Cause: There is an error in the element settings.The Element Result setting is Matrix for two consecutive
lines for a part with Vision Type 230 or 231.
Remedy: Do not specify a Result setting of Matrix for consecutive lines for a part with Vision Type 230 or
231.
------------------------------
Code: 2300E592
Display: With Vision Type **,Matrix is not a compatible Result setting.
Used by:
Cause: With the specified Vision Type,the Result setting of Matrix is not compatible.
Remedy: Check the element Result setting.Check the Vision Type setting.
------------------------------
Code: 2300E593
Display: The Result setting will be treated as Inspect.
Used by:
Cause: With the specified Vision Type,the only compatible Result setting is Inspect.Processing will
continue with a Result setting of Inspect.
Remedy: Check the element Result setting.Check the Vision Type setting.
------------------------------
Code: 2300E594
Display: A Lead Quantity setting of 17 or more is not supported for Vision Type 20.
Used by:
Cause: Vision Type 20 does not allow a "Lead Quantity"setting value of 17 or higher.
Remedy: Create the part data using vision type 18 or 100.
------------------------------
Code: 2300E595
Display: For Vision Type 180,the total number of leads in [Lead Quantity]for an element whose Result
setting is Inspect must be 2,3,or 4.
Used by:
Cause: For Vision Type 180,the total number of leads in [Lead Quantity]for an element whose Result
setting is Inspect must be 2,3,or 4.
Remedy: Check the Result settings.
第 2137 页
Check the Element settings.
Change the Vision Type.
------------------------------
Code: 2300E5B0
Display: [Packaging Type]-[Feed Count] is not defined.
Used by:
Cause: A [Packaging Type]-[Feed Count] setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
Remedy: Specify a [Packaging Type]-[Feed Count] setting when the [Packaging Type]-[Type] setting is other
than [0:Tray], [4:Stick Feeder], [5:Grooved Stick Feeder].
------------------------------
Code: 2300E5B1
Display: Tape Width is not defined.
Used by:
Cause: A Packaging Data "Tape Width" setting of "0" existed when the [Packaging Type]-[Type] setting
was other than [0:Tray].
Remedy: Specify a "Tape Width" setting.
------------------------------
Code: 2300E5B2
Display: Set a value less than 4 if the Packaging Type is specified as Stick Feeder or Grooved Stick feeder.
Used by:
Cause: The stick feeder "FeedCount" is set to 4 or more.
Remedy: When using the Stick Feeder and Grooved Stick Feeder packaging types, specify a "FeedCount"
setting of 3 or less.
------------------------------
Code: 2300E5B3
Display: Make a setting at Packaging Type.
Used by:
Cause: Packaging Type is not specified in the part packaging data.
Remedy: Specify the packaging type in the Packaging edit window.
------------------------------
Code: 2300E5D0
Display: Tray Length is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Length" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Length" setting.
------------------------------
Code: 2300E5D1
Display: Tray Width is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but there is no "Tray Width" setting.
Remedy: When using the "Tray" packaging type, specify a "Tray Width" setting.
------------------------------
Code: 2300E5D2
Display: Tray Column Quantity is not defined.
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Column Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Column Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D3
Display: Tray Row Quantity is not defined.
第 2138 页