Code: 2100F032 Display: Black_or_white data error in mark_data Used by: Cause: There is an entry error in the B/W section of mark_data. Remedy: Input either "B" or "W" in this section. ---------------…
Code: 2100F02A
Display: Mark seq. not found compare mark data
Used by:
Cause: The fiducial mark data referred to by a fiducial mark reading sequence does not exist.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02B
Display: Check flag data read error
Used by:
Cause: The data check flag could not be read from the header.
Remedy: Use the editor to check that the file is correct.
------------------------------
Code: 2100F02C
Display: x, y data overflow PCB range
Used by:
Cause: A sequence data X or Y value exceeds the permitted range for the board.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02D
Display: Blk0 mount seq and except Blk0 seq intermingled
Used by:
Cause: Placing sequences for Block 0 and placing sequences for other blocks are mixed together.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F02E
Display: Undefined M/C type data on check table
Used by:
Cause: The specified machine type data does not exist in the data check table.
Remedy: Contact Fuji.
------------------------------
Code: 2100F02F
Display: Bskip0 seq. should be set before the others bskip seq
Used by:
Cause: The block skip sequences in Block 0 must appear before the block-skip sequences of all blocks
except Block 0.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F030
Display: Working mode no much to machine type
Used by:
Cause: The sequence type and machine type do not match.
Remedy: Check the sequence type of the sequence in question. The FGL-2 uses D,F, G, T and B. The
GSP-2 uses D, F and M sequences. The FEP-20 uses D and B sequences. The FEPGL and FGL use D and
T sequences. Other machines use D, F and B sequences.
------------------------------
Code: 2100F031
Display: Mark_type data error in mark_data
Used by:
Cause: The mark type and the sequence type are not the same.
Remedy: Check that the mark type and the sequence type are the same type.
------------------------------
第 2104 页
Code: 2100F032
Display: Black_or_white data error in mark_data
Used by:
Cause: There is an entry error in the B/W section of mark_data.
Remedy: Input either "B" or "W" in this section.
------------------------------
Code: 2100F033
Display: L/S error in mark_data
Used by:
Cause: There is an error in the L/S section of the mark_data.
Remedy: Input either "L" or "S" in the L/S section.
------------------------------
Code: 2100F034
Display: Part data not found
Used by:
Cause: The Part data was not found for a certain device.
Remedy: Check that the Part data file has Part data for the device on which the error occurred.
------------------------------
Code: 2100F035
Display: This component hight is over range
Used by:
Cause: The part height entered in the program for the FCP-2/3 is too high. The maximum allowable
heights are 4.5 mm (FCP-2) and 6.0 mm (FCP-3).
Remedy: Check the appropriate device in Part data.
------------------------------
Code: 2100F036
Display: This component should be set befor the 4.5mm hight
Used by:
Cause: On the FCP-3, a part higher than 4.5 mm is followed by a part lower than 4.5 mm.
Remedy: Correct the order of the sequence.
------------------------------
Code: 2100F037
Display: Mask sequence is out of order
Used by: GP2,GP3
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F038
Display: Block0 fidutial sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F039
Display: Block 0 block skip sequence is out of order
第 2105 页
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03A
Display: Block skip sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03B
Display: Fiducial sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03C
Display: Memory allocation error
Used by:
Cause: Memory space could not be allocated.
Remedy: Contact Fuji.
------------------------------
Code: 2100F03D
Display: Holder number is not definition
Used by:
Cause: The holder number is undefined.
Remedy: Input the holder number under the HM heading in the second page of sequence data.
------------------------------
Code: 2100F03E
Display: Beyond the limits of holder number
Used by:
Cause: A number outside the correct range (1-4 on the IP2) was entered.
Remedy: Check that numbers within the correct range have been entered.
------------------------------
Code: 2100F03F
Display: Holder number is not light with device number
Used by:
Cause: The holder number and the device number are not matched correctly.
Remedy: On the IP2, holder 1 covers devices 1 ~ 37 and 101 ~ 110, holder 2 covers devices 4 ~ 37, holder
3 covers devices 51 ~ 84 and holder 4 covers devices 51 ~ 87. Check that the holder number is not
specified outside this range.
------------------------------