notify Fuji. ------------------------------ Code: 12037AD? Display: INTL SRV version error Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541 Cause: This error involves the internal processing of the machi…
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A8?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified deceleration time was too long. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037A9?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo because the parameter-specified generate size was out of range. This error occurred when Fuji
OS system call_create_reduce() was used. The last number in the error code indicates the axis in which
the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AA?
Display: Reduce data creation error
Used by: CP3,CP4-1,CP4-2,CP4-3,GP551,GP6
Cause: An error occurred when an attempt was made to generate the deceleration function data used by
the servo. This error occurred when Fuji OS system call_create_reduce() was used. The last number in
the error code indicates the axis in which the error occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AB?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred due to a lack of memory when an attempt was made to generate the
acceleration function data used by the servo. This error occurred when Fuji OS system
call_create_reduce() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037AC?
Display: Accel data creation error
Used by: CP3
Cause: An error occurred when an attempt was made to generate the acceleration function data used by
the servo because the specified parameter was unsuitable. This error occurred when Fuji OS system
call_create_accel() was used. The last number in the error code indicates the axis in which the error
occurred.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
第 464 页
notify Fuji.
------------------------------
Code: 12037AD?
Display: INTL SRV version error
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541
Cause: This error involves the internal processing of the machine software. The "intelligent Servo Power
Version Check" with " system call_intl_ver_chk()" discovered the FUJI OS to be v2.17 or earlier.The last
digit of the error code indicates the number of the board in which the error occurred. "0" indicates board
one. (? represents the board in which the error occurred.)
Remedy: Boot up the machine using the reset-start procedure. If the machine still does not work properly
or if this problem occurs often, contact Fuji.
------------------------------
Code: 12038000
Display:
Used by: CP732E,CP742ME,CP742E,CP752E,NP133E,NP134E,NP153E
Cause: Control power for the servo amplifier was cut due to an outage of 100msec,resulting in an
encoder communication error. This error is caused when the servo amplifier's control power is cut, not
due to an error in the encoder itself.
Remedy: Be sure to shutdown the machine according to the instructions on the monitor and restart the
machine.
------------------------------
Code: 12040101
Display: TAPE END
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP642,CP643
Cause: Even though there are still parts in the tape,the machine(CP3) has detected the end of the tape
end and has stopped operation. The machine stops underthese conditions only if the third bit in
"Machine_status" is set to "1"(4H).
Alternatively, when the large part check is performed, no part ie detected on the nozzle and the machine
assumes that the tape is at an end.
Remedy: Check the feeder. Replenish the part supply. If parts have not run out check the tape end sensor
or check for tape wobbling during pickup.
------------------------------
Code: 12040102
Display: Parts Out
Used by: CP5
Cause: The small part sensor detected that small parts were not being picked. The machine is out of
parts.
Remedy: Replenish the parts supply. If parts have not run out check the tape end sensor and check the
tape for wobbling during pickup.
------------------------------
Code: 12040103
Display: Parts Out(CP5) D*** Supply(CP4)
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: When the large part check is performed(CP5),there is no part on the nozzle,and the tape end
sensor confirms that parts have run out.
when the part is inspected,no part is found on the nozzle and the machine stops when the tape end sensor
confirms that the parts have run out,or recovery is performed and the machine stops when it is unable to
pick up a part.
Remedy: Replenish the parts. If not out of parts, check the tape end sensor and whether on not there is
vibration in the tape.
------------------------------
第 465 页
Code: 12040104
Display: Supply components PM??:D**
Used by: CP3,CP5,IP1,IP2,IP3
Cause: No part was picked up. The machine stopped because the tape end sensor detected the end of
the tape or recovery was attempted the number of times specified. D** indicates the device number.
Remedy: Replenish the parts. If there are already parts, check that the machine is picking properly, and
check that the feeder is mounted properly.
------------------------------
Code: 12040105
Display: Supply tray
Used by: IP2
Cause: There is no MTU tray.
Remedy: Replenish the tray.
------------------------------
Code: 12040106
Display: "Empty Check L" (GL), "Empty Check Z1" (FGL5)
Used by: GL2,GL5,GL541
Cause: There is very little glue remaining in each syringe.
Remedy: Add glue, or replace the syringe. If an error occurs, the machine can be started by pressing the
START button but it will stop again after one board has been completed.
------------------------------
Code: 12040107
Display: "Empty Check R" (GL), "Empty Check Z2" (GL5)
Used by: GL2,GL5,GL541
Cause: The amount of glue remaining in syringes is low.
Remedy: Add glue, or replace syringes. The machine will restart operation if the START button is pressed
while this error state is in effect, but it will stop again after applying glue to one board. It is possible to
prevent the machine from checking the amount of glue remaining by adding a value of 1 for the "Machin
status A" parameter in the Proper data.
------------------------------
Code: 12040108
Display: "Empty Check Z3" (GL5)
Used by: GL5,GL541
Cause: The amount of glue remaining in syringes has become low.
Remedy: Add glue, or replace syringes. The machine will restart operation if the START button is pressed
while this error state is in effect, but it will stop again after applying glue to one board. It is possible to
prevent the machine from checking the amount of glue remaining by adding a value of 1 for the "Machin
status A" parameter in the Proper data.
------------------------------
Code: 12040109
Display: Supply Components
Used by: IP1,IP2,NP132,NP133
Cause: All the specified next devices have been used up.
Remedy: Register that the next devices have been replenished. Refer to the appropriate operation manual
for more information about next devices.
------------------------------
Code: 1204010A
Display: NO parts D***
Used by: IP1
Cause: The parts check sensor has detected that there are no parts and the machine has gone out of
automatic operation.