FUJI错误代码查询.pdf - 第1101页

be OFF. Remedy: Make sure the out-carrier board sensors (the I/O input signals listed below) tuen ON and OFF correctly. I/O input signals: LX038: OUT-carrier 1 board sensor LX039: OUT-carrier 2 board sensor -------------…

100%1 / 5282
presence of boards on the conveyor.
I/O input signals:
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010D02
Display: Board-clamper error:O_CRRY
Check board clamp/unclamp limits on the O_CRRY
Used by: CP643
Cause: The out-carrier was closed,but the closed sensor did not turn ON within the specified time.
The out-carrier was opened,but the opened sensor did not turn ON within specified time.
The out-carrier opened and closed sensors are both ON.
Remedy: Make sure the out-carrier opens and closes smoothly.
Make sure the opened and closed sensors have been attached at the correct positions.
Make sure the opened and closed sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the opened and closed sensors (the I/O input signals listed below) turn ON and OFF correctly
when the out-carrier is opened and closed.
I/O input signals:
LX048: OUT-carrier left front closed sensor
LX049: OUT-carrier left rear closed sensor
LX04A: OUT-carrier right front closed sensor
LX04B: OUT-carrier right rear closed sensor
LX04C: OUT-carrier left front opened sensor
LX04D: OUT-carrier left rear opened sensor
LX04E: OUT-carrier right front opened sensor
LX04F: OUT-carrier right rear opened sensor
------------------------------
Code: 15010D03
Display: Board check error:O_CRRY
No brd on out-carrier Chk status of brd
Used by: CP643
Cause: An out-carrier board sensor did not confirm a board (that is,the sensor did not turn ON) loaded
onto the out-carrier from the main lifter.
An out-carrier board sensor has turned OFF (indicating that the first or second
board is absent) before the out carrier began retracting,after having indicated
the presence of the board in question when that board was loaded onto the out-carrier from main lifter.
An out-carrier board sensor has turned OFF (indicating that the first or second
board is absent) before the out-carrier began retracting,after having indicated
the presence of the board in question during a board check performed when the out-carrier was at the
extended limit.
Remedy: Adjust the out-carrier board sensors (the I/O input signals listed below) ensuring they correctly
detect the presence of boards clamped by the out-carrier.
I/O input signals:
LX038: Out-carrier 1 board sensor
LX039: Out-carrier 2 board sensor
------------------------------
Code: 15010D04
Display: Board check error:O_CRRY
Out-carr brd conf sensor on Adj sensor so it turns off
Used by: CP643
Cause: The out-carrier board sensors are abnormal. ( For example,a sensor is ON even though it should
第 1100 页
be OFF.
Remedy: Make sure the out-carrier board sensors (the I/O input signals listed below) tuen ON and OFF
correctly.
I/O input signals:
LX038: OUT-carrier 1 board sensor
LX039: OUT-carrier 2 board sensor
------------------------------
Code: 15010D05
Display: Cylinder cycle alarm:O_CRRY
O_CRRY board transfer time up
Used by: CP643
Cause: The out-carrier was extended,but the extended limit sensor did not turn ON within the specified
time.
The out-carrier was retracted,but the retracted limit sensor did not turn ON within the specified time.
The out-carrier extended and retracted limit sensors are both ON.
Remedy: Make sure the out-carrier extends and retracts smoothly.
Make sure the extended and retracted limit sensors have been attached at the correct positions.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF
correctly when the out-carrier is extended and retracted.
I/O input signals:
LX03C: OUT-carrier extended limit sensor
LX03D: OUT-carrier retracted limit sensor
------------------------------
Code: 15010D06
Display: Interlock alarm:O_CRRY
Used by: CP643
Cause: The machine was not able to extend the out-carrier because there is a board in the out-lifter,but
it was not sure whether there is a board clamped in the out-carrier. If the out-carrier has clamped a board
with parts mounted on the reverse side, there may be interference between the board and the one in the
out-lifter.
The machine was not able to retract the out-carrier because there is a board on
the out-lifter,and there is also a board clamped in the extended out-carrier.if
the board clamped in the out-carrir has parts mounted on the reverse side,there
may be interference between this board and the one on the out-lifter.
The machine was not able to retract the out-carrier from a position between the
extended limit and the retracted limit because there is a board on the out-lifter,but it is not sure whether
there is a board clamped in the out-carrier.if the
out-carrier has clamped a board with parts mounted on the reverse side,there may be interference
between this board and the one on the out-lifter.
Remedy: Remove any boards from in the out-lifter.
Make sure the out-lifter board arrival sensors (the I/O input signals listed below) detect the presence of
boards in the out-lifter.
I/O input signals:
LX00C: OUT1/OUT2 board gap sensor
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010D07
Display: Interlock alarm:O_CRRY
Out-carrier not at extended position.
第 1101 页
Used by: CP643,CP643M
Cause: Main conveyor movement for the conveyance of board(s) was terminated because the out-carrier
is out of position.
Remedy: If the out-carrier is at its extended position, check the extended and unclamping limit sensors.If
the extended and unclamping limit sensors are on, the carrier may be moving too fast and has recoiled out
of position.If the carrier is not at its extended position the movement of the carrier itself may require
adjustment.
------------------------------
Code: 15010D08
Display: Board-clamper error:O_CRRY
The clamp confirmation sensor on the OUT-carrier forward limit is unstable.
Used by: CP643,CP643M
Cause: The clamp sensor operation is unstable at the out-carrier's advance limit side.
Remedy: Check the clamp sensor operation, and verify that the conveyor width is suitable for the panel in
question.
------------------------------
Code: 15021000
Display: Remove Board from Main Cvyr
Used by: IP3
Cause: Either there was a main conveyor board check sensor alarm or the sensor is not correctly
adjusted. The board was moved by hand.
Remedy: If the board has been produced, unload it. If not, put the board back into the in conveyor.
------------------------------
Code: 15021001
Display: Not defined.
Used by:
Cause: Operation was cancelled because of an alarm from the application.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs frequently,
contact Fuji.
------------------------------
Code: 15021002
Display: Not defined.
Used by:
Cause: Loading position alarm.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021003
Display: Not defined.
Used by:
Cause: Lifter position error.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021004
Display: Interlock on(cp6)
Interlock Board transfer check(gsp5)
Used by: GSP5,GP551,GP6,IP3
Cause: The machine attempted to clamp the table while the board detect sensor on either the in or out-
conveyor was on.
Remedy: Remove the board.
第 1102 页