FUJI错误代码查询.pdf - 第437页

Code: 1203540B Display: Used by: CP5,CP6,CP6M,CP65 Cause: Axis number 1 synchronicity error. Remedy: Cut the machine power. ------------------------------ Code: 1203540C Display: Used by: CP6,CP6M,CP65,GP551,GP6 Cause: T…

100%1 / 5282
Cause: Axis number 4 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035403
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035404
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035405
Display:
Used by: CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 4 + soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035406
Display:
Used by: CP6,CP6M,CP65,GP551,GP6,NP132,NP133,QP132
Cause: Axis number 4 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035407
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 4 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035408
Display:
Used by: CP5,CP6,CP6M,CP65,QP132
Cause: Axis number 4 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035409
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Incorrect parameter was sent from axis number 4.
Remedy: Turn off the machine power.
------------------------------
Code: 1203540A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132,NP133E,NP134E,NP153E
Cause: Axis number 4 encoder error.
Remedy: Turn off the machine power.
------------------------------
第 436 页
Code: 1203540B
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 1 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 1203540C
Display:
Used by: CP6,CP6M,CP65,GP551,GP6
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
Code: 12035501
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3
Cause: Axis number 5 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035502
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3
Cause: Axis number 5 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035503
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3,NP132,NP133
Cause: Axis number 5 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035504
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3,NP132,NP133
Cause: Axis number 5 deviation overflow.
Remedy: Turn off the machine power.
------------------------------
Code: 12035505
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3
Cause: Axis number 5 + soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035506
Display:
Used by: CP5,CP6,CP6M,CP65,GP551
Cause: Axis number 5 - soft limit.
Remedy: Turn off the machine power.
------------------------------
Code: 12035507
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3
第 437 页
Cause: Axis number 5 not ready.
Remedy: Turn off the machine power.
------------------------------
Code: 12035508
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 5 emergency stop.
Remedy: Turn off the machine power.
------------------------------
Code: 12035509
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3
Cause: Incorrect parameter was sent from axis number 5.
Remedy: Turn off the machine power.
------------------------------
Code: 1203550A
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,IP3,NP133E,NP134E,NP153E
Cause: Axis number 5 encoder error.
Remedy: Turn off the machine power.
------------------------------
Code: 1203550B
Display:
Used by: CP5,CP6,CP6M,CP65
Cause: Axis number 5 synchronicity error.
Remedy: Cut the machine power.
------------------------------
Code: 1203550C
Display:
Used by: CP5,CP6,CP6M,CP65,GP551
Cause: The servo interlock was activated during startup.
Remedy: Check the interlock sensor.
------------------------------
Code: 12035601
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,IP3
Cause: Axis number 6 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035602
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,IP3
Cause: Axis number 6 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035603
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,IP3,NP132,NP133
Cause: Axis number 6 placement time too long.
Remedy: Turn off the machine power.
------------------------------
第 438 页