FUJI错误代码查询.pdf - 第565页

- Pallet sensor (IN:X076) (OUT:X07E): on Unclamp state: - Pallet clamp sensor (IN:X074) (OUT:X07C): off - Unclamp sensor (IN:X075) (OUT:X07D): on - Pallet sensor (IN:X076) (OUT:X07E): on Irregular state: Anything outside…

100%1 / 5282
setup station and the in-position.
Remedy: Check the slide's extended position.
Check the I/O signal X070 when the slide is at its extended position.
------------------------------
Code: 12054095
Display: "SETUP_ST. OUT Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the out-
setup position and the out-position.
Remedy: Check the slide's extended position.
Check the I/O signal X078 when the slide is at its extended position.
------------------------------
Code: 12054096
Display: "Pallet Clamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: Before operation is started:
- The setup station's (in/out) pallet clamp is not engaged properly or, the state in which it is disengaged is
abnormal.
- There is a pallet at the setup station (in/out) as well as the pallet's ID information data but the pallet is
not clamped.
During operation:
- The pallet that arrived at the setup station (in/out) can not be clamped properly when the attempt is
made.
Remedy: Check that the pallet is clamped properly at the setup station (in/out).
Check the input status for each of the clamping pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Check that the D-axis pallet ID data matches that of the current pallet position using the command
sequence [SET] -> [POSITION] -> [SET PALLET] -> [DEFINE].
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
- Pallet sensor (IN:X076) (OUT:X07E): on
Unclamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): off
- Unclamp sensor (IN:X075) (OUT:X07D): on
- Pallet sensor (IN:X076) (OUT:X07E): on
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054097
Display: "Pallet Unclamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: The pallet clamp attempted to disengage when the pallet moved from the setup station (in/out),
but has not disengaged properly.
Remedy: Check the input status for each of the setup stations' clamp pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
第 564 页
- Pallet sensor (IN:X076) (OUT:X07E): on
Unclamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): off
- Unclamp sensor (IN:X075) (OUT:X07D): on
- Pallet sensor (IN:X076) (OUT:X07E): on
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054098
Display: "Filler Conveyor Set Error"
Used by: CP652C
Cause: When the PPS filler operation is performed, the filler conveyor is not set correctly at the time the
pallet moves from the return conveyor to the filler conveyor.
When the PPS filler operation is not performed, the filler conveyor set sensor is detecting the presence of
the filler conveyor.
Remedy: Check the set status of the filler conveyor.
When the filler conveyor has not been set, the input status for each of the sensors are as follows:
Set state:
- Joint conveyor present X095:X
- Joint conveyor set sensor 1 X096: O
- Joint conveyor set sensor 2 X097: O
Unset state:
- Joint conveyor present X095:O
- Joint conveyor set sensor 1 X096: X
- Joint conveyor set sensor 2 X097: X
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054099
Display: 周期异常 洗净剂喷嘴
Used by: GPX,GPX-C
Cause: 洗净剂喷嘴在规定时间内没有动作
Remedy: 1.如果存在妨害洗净剂供应喷嘴上下动作的东西,请除去障害物。
2.如果没有障害物,请通过I/O确认洗净剂供应喷嘴上下的输入,检查洗净剂供应喷嘴上下解除确认的传感器。
(RX00A.00B)(请与敝公司Support联系)
3.如果子编码中显示UpDown Sensor Adjustment,请进行溶剂供应的上升下降端传感器位置的调整。
<img src="$LKEY_ERRIMG_MC$/EI0022.bmp">
------------------------------
Code: 1205409A
Display: 周期异常 轮廓夹紧
Used by: GPX,NXTP,GPX-C
Cause: 轮廓夹紧的导入端或退出端在规定时间内没有ON。
轮廓夹紧的导入、退出的传感器同时ON着。
Remedy: 1.如果有障害物(电路板等),请除去障害物。
2.请通过I/O检查轮廓夹紧导入确认和轮廓夹紧解除确认的传感器(GPX:RX001-004, NXTP:RX00D-020)。(请与
敝公司Support联系)
3.Sensor Adjustment:请进行轮廓夹紧导入退出端传感器的调整。
<img src="$LKEY_ERRIMG_MC$/1205409A.PNG">
------------------------------
Code: 1205409B
Display: 周期异常 框松开
第 565 页
Used by: GPX,NXTP,GPX-C
Cause: 在规定时间内不能够松开网板框。
Remedy: 1.请确认是否有妨害框松开动作的东西。
2.如果框没有被正常地松开,需要进行传感器(X01A)的调整。(请与敝公司Support联系)
<img src="$LKEY_ERRIMG_MC$/1205409B.PNG">
------------------------------
Code: 1205409C
Display: 周期异常 洗净剂喷嘴旋转
Used by: GPX,GPX-C
Cause: 洗净剂喷嘴旋转没有在规定时间内结束。
Remedy: 1.如果有妨害洗净剂供应喷嘴旋转的障害物,请除去障害物。
2.请通过I/O检查洗净剂供应喷嘴旋转导入确认和洗净剂供应喷嘴旋转解除确认的传感器。(RX00C,00D)(请与敝
公司Support联系)
3.如果子编码中显示Sensor Adjustment,请进行溶剂供应旋转的导入退出端传感器位置的调整。
<img src="$LKEY_ERRIMG_MC$/EI0022.bmp">
------------------------------
Code: 1205409D
Display: 基座夹紧动作异常
Used by: NXTP
Cause: 基座夹紧在规定时间内不能动作。
Remedy: 1.请确认是否有干涉物。2.请调整动作速度。3.进行传感器输入调整。
<img src="$LKEY_ERRIMG_MC$/1205409D.PNG">
------------------------------
Code: 1205409E
Display: 框推杆动作异常
Used by: NXTP
Cause: 框推杆不能在规定时间内动作。
Remedy: 1.请确认有无干涉物。2.请调整动作速度。3.请调整传感器的输入。
<img src="$LKEY_ERRIMG_MC$/1205409E.PNG">
------------------------------
Code: 1205409F
Display: 周期循环异常 出界制动器
Used by: NXTP
Cause: 出界制动器在规定时间内没动作。
Remedy: 1.请确认没有干涉物。
2.请进行动作速度的调整。
3.请进行传感器输入调整。
<img src="$LKEY_ERRIMG_MC$/1205409F.PNG">
------------------------------
Code: 120540A0
Display: 周期循环异常 通道2制动器
Used by: NXTP
Cause: 通道2制动器在规定时间内没动作。
Remedy: 1.请确认没有干涉物。
2.请进行动作速度的调整。
3.请进行传感器输入调整。
<img src="$LKEY_ERRIMG_MC$/120540A0.PNG">
------------------------------
Code: 120540A1
Display: 周期循环异常 往复臂L制动器
Used by: NXTP
第 566 页