FUJI错误代码查询.pdf - 第131页

Used by: NXTP Cause: 发生了关于焊锡供应设定的矛盾,成为不能供应焊锡状态。 请确认创建的生产程序是否符合以下条件。 Remedy: 请调整焊锡供应行程、焊锡供应速度、吸嘴残留焊锡调整定时器、供应结束位置焊锡量调整定时器的4个参 数并满足以下条件。 供应行程/供应速度 > 吸嘴残留焊锡调整定时器 + 供应结束位置焊锡量调整定时器 ------------------------------ Code: 1101E…

100%1 / 5282
"PCB_DISTANCE" is used at the start of production to check whether the mid-stopper has beeb set at a
position appropriate to the production program
being executed. It is essential that the value be entered even for single board
production programs.
------------------------------
Code: 1101E04?
Display: Same as Code.
Used by: QP132
Cause: The largest and the smallest sized nozzles are set together in the NAT. It is not physically
possible to insert these sizes together in this manner (e.g., setting nozzle size A and nozzle size E together
on the same side of the placing head).
"?" represents the module number in hexadecimal format. ("0" is module 16)
Remedy: Correct the NAT settings.
------------------------------
Code: 1101E050
Display: same as code.
Used by: CP643
Cause: The single board production indicator has been set in the Proper data,but the production
program indicates double board production.
Remedy: Set the item "Multiple PCB set" in the production program to 1.
------------------------------
Code: 1101E051
Display: same as code.
Used by: CP643
Cause: The board thickness to be handled by the machine is calculated as follows: Origin Position Z -
Min Limit Position Z > PCB thickness + 5 mm. PCB thickness cannot be set to a value less than 0.3 mm.
The current settings at Proper data item "Min Limit Position Z" (mark reading) and/or part data item PCB
thickness (board check) have caused this value to be out of range.
Remedy: Change the PCB thickness, or check the Z-axis Proper data (Min Limit Position Z) setting.
------------------------------
Code: 1101E052
Display: 离板速度超出范围
Used by: NXTP
Cause: 离板速度超出范围。
Remedy: 请确认在FujiFlexa上设定的离板速度。
·公差值范围:从0.09到40[mm/sec]
·不能减速设定(可以相同速度)。
------------------------------
Code: 1101E053
Display: 清洁设定错误
Used by: GPX,NXTP
Cause: 有关清洁的设定发生了矛盾。
请确认使用Job编制器创建的生产程序是否符合以下的条件。
·ProcessOptions标签页:设定自动清洁的实行频率为1块以上。
·Clean Mask标签页:第一个记录设定Option(None)的数据。
(SP清洁与此相同。)
Remedy: 不进行清洁时,设定实行频率为0块。
进行清洁时,指定Option为None以外。
------------------------------
Code: 1101E054
Display: 焊锡自动供应设定错误
第 130 页
Used by: NXTP
Cause: 发生了关于焊锡供应设定的矛盾,成为不能供应焊锡状态。
请确认创建的生产程序是否符合以下条件。
Remedy: 请调整焊锡供应行程、焊锡供应速度、吸嘴残留焊锡调整定时器、供应结束位置焊锡量调整定时器的4个参
数并满足以下条件。
供应行程/供应速度 > 吸嘴残留焊锡调整定时器 + 供应结束位置焊锡量调整定时器
------------------------------
Code: 1101E055
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1101E056
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1101E1??
Display: NAT data error.
Used by: QP132
Cause: NAT data has not been set or, despite being part of the same family, the NAT structure is
different.
The first "?" of the "??" represents the head number ("0" is head 16). The following "?" represents the item
(1: Nozzle diameter. 2: Backlight diameter. 3: Nozzle type).
Remedy: Set the correct values in NAT data.
------------------------------
Code: 1101E200
Display: 1101E200
Used by: IP3
Cause: A positive value was entered for part data item "Fst_pickup_pnt_x" or "Tray_pickup_pnt_x".
Remedy: The X or Y-axis may interfere with the tray. Input a negative value for part data item
"Fst_pickup_pnt_x" or "Tray_pickup_pnt_x".
------------------------------
Code: 1101E201
Display: 1101E201
Used by: IP3
Cause: A negative value was entered for part data item "Fst_pickup_pnt_y" or "Tray_pickup_pnt_y".
Remedy: The X or Y-axis may interfere with the tray. Input a positive value for part data item
"Fst_pickup_pnt_y" or "Tray_pickup_pnt_y".
------------------------------
Code: 1101E202
Display: Same as code
Used by: IP3
Cause: Device positions D36 and D37 cannot be used due to the camera type set in Proper data.
Remedy: Move the devices at device positions D36 and D37 to alternative positions.
------------------------------
Code: 1101E203
Display: Same as code
Used by: IP3
第 131 页
Cause: Device positions D51 and D52 cannot be used due to the camera type set in Proper data.
Remedy: Move the devices at device positions D51 and D52 to alternative positions.
------------------------------
Code: 1101E204
Display: Same as code
Used by: GP551, GP641
Cause: The pressure applied to the pusher during printing is outside
the permissible range.
Remedy: Ensure that a value within the range 0.5 to 5.0 [kgf/cm2] is specified at the production program
item "Pusher Pressure During Print"
or at the sequence data item "Print Pusher Seq (F4G) MM (MCS)".
If "0" is specified at the above sequence data item, the "Pusher Pressure During Print" item is referenced.
GP-551E version V1.12, or GP-641E version V1.23 are required to support sequential pusher pressure
settings.
------------------------------
Code: 1101E205
Display: Same as code
Used by: GP551, GP641
Cause: The pressure applied to the pusher during solder supply is outside the permissible range.
Remedy: Ensure that the production program item "Pusher Pressure After Refill" is within the range of 0.5
to 5.0 kgf/cm2.
------------------------------
Code: 1101E206
Display: Same as code
Used by: QP242
Cause: The selected nozzle station is not fitted on the machine.
Remedy: The selected nozzle station is not fitted on the machine. The setting for "Nozzle Station ID" in
the production program is different in Proper data.
------------------------------
Code: 1101E207
Display: Same as code
Used by: CP643,CP7series,QPseries,NPseries,GL541
Cause: The Pcb_position_tolerance item in the production program is set to a value greater than mark
data scan value.
Remedy: Set Pcb_position_tolerance to a value less than the Scan value in mark data.
------------------------------
Code: 1101E208
Display: Same as code
Used by: QP242
Cause: Fiducial mark data not found in header data.
Remedy: Enter fiducial mark data in the program header.
------------------------------
Code: 1101E300
Display: 没有设定基准定位点。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 没有设定生产程序的基准定位点。
Remedy: [机上编辑] 请在定位点编辑画面上设定基准定位点。
[Fuji Flexa] 请设定基准定位点。
------------------------------
Code: 1101E301
Display: 没有设定子电路板跳过定位点。
第 132 页