Code: 2306003E Display: The stage/slot numbers for the following feeder setup in the program file are zero. Used by: Cause: Because either the stage or slot number is zero, the device number is referenced for calculation…

100%1 / 5282
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23060037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23060039
Display: No compatible nozzle diameter exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no Nozzle Diameter could be found within
the range defined by Minimum Nozzle Diameter and Maximum Nozzle Diameter in the part data.
Remedy: Check the Minimum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum
Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2306003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 2306003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 2306003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 100. When the stage
number value is 2, the slot number input range is 1 to 400.
------------------------------
第 2167 页
Code: 2306003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 2306003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 23060040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 100. When the stage
number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 23060042
Display: Even if nozzle kinds are combined so that the maximum diameter nozzles are not used, there are
too many nozzle kinds to fit in the folder.
Used by:
Cause: When using automatic nozzle arrangement, the required number of nozzles exceed the number in
the nozzle folder.
Remedy: The program file is incorrect. Check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23060044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Optimized
Nozzle Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP341ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP341ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23060045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
第 2168 页
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle Arrangement] method. If using [Automatic Optimized
Nozzle Arrangement], check the Nozzle Spec. file, or check the Nozzle Name
(PARTS/ENVDT/XP341ENVDT-/PENNZN) in the part data.
------------------------------
Code: 23060047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23060048
Display: A Alt. Feeder is duplicated, or two or more first slots (reference slot) have been specified for the
same alternate feeder loop. The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230600A1
Display: The source program is already in an optimized condition. It is not possible to further optimize the
source program.
Used by:
Cause: The post-optimized theoretical cycle time is slower than the pre-optimized time, however, source
program sequence or feeder setup problems have been fixed.
Remedy: It may be possible to achieve a better cycle time result by changing the optimization conditions,
if production constraints allow.