FUJI错误代码查询.pdf - 第2102页

Code: 2100F01A Display: This program is over sequence Used by: Cause: The length of the sequence data exceeds the fixed limit. Remedy: Correct the appropriate data. ------------------------------ Code: 2100F01B Display: …

100%1 / 5282
Cause: The **** data in the production mode data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F012
Display: M/C data: %s over range
Used by:
Cause: The **** data in the machine data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F013
Display: PCB data: %s over range
Used by:
Cause: The **** data in the PCB data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F014
Display: Mark data: %s out of range
Used by:
Cause: The **** data in the mark data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F015
Display: Dev data: %s over range
Used by:
Cause: The **** data in the device data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F016
Display: MB data: %s over range
Used by:
Cause: The **** data in the multi-block offset data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F017
Display: Seq data: %s over range
Used by:
Cause: The **** data in the sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F018
Display: Mark seq: %s over range
Used by:
Cause: The **** data in the fiducial mark reading sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F019
Display: Placing seq: %s over range
Used by:
Cause: The **** data in the placing sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
第 2101 页
Code: 2100F01A
Display: This program is over sequence
Used by:
Cause: The length of the sequence data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01B
Display: This program is over device
Used by:
Cause: The length of the device data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01C
Display: Duplicate mark number
Used by:
Cause: A fiducial number appears more than once in the sequence data.
Remedy: Contact Fuji.
------------------------------
Code: 2100F01D
Display: This sequence should be set before compare Mark seq
Used by:
Cause: A placing sequence appears before the mark reading sequence to which it refers in the sequence
data.
Remedy: Correct the position of the fiducial mark reading sequence in the sequence data.
------------------------------
Code: 2100F01E
Display: Duplicate mark number on block 0
Used by:
Cause: The mark number in the Block 0 fiducial mark sequence appears again somewhere else in the
sequence data.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01F
Display: Mark seq. on block0 should be set before compare seq
Used by:
Cause: The fiducial mark sequences in the Block 0 must appear before all other sequence data (except
the Block 0 block-skip sequences).
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F020
Display: Blk. skip seq: %s data over range
Used by:
Cause: The **** data in the block-skip sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F021
Display: Blk. skip seq. should be set before the others
Used by:
Cause: The block-skip sequences must appear before all other sequence data (except the block 0 fiducial
mark sequences).
Remedy: Place the block skip sequences in front of all others (except the block 0 fiducial mark
第 2102 页
sequences).
------------------------------
Code: 2100F022
Display: Blk skip seq.Not found compare mark data
Used by:
Cause: The mark data referred to by the block-skip sequence does not exist.
Remedy: Create the appropriate mark data.
------------------------------
Code: 2100F023
Display: Mark.seq.on block0 should be set before blk. skip seq
Used by:
Cause: The fiducial mark sequences in the Block 0 must appear before the block-skip sequences of all
blocks except Block 0.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F024
Display: D_No. PD **** Undefined part sort on PDG
Used by:
Cause: The **** data in the Part Data does not exist.
Remedy: Create the appropriate Part Data.
------------------------------
Code: 2100F025
Display: Placing seq: Undefined MM data
Used by:
Cause: The main fiducial mark is not specified in the placing sequence (when using the fiducial marks).
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F026
Display: Placing seq: Not found compare device data
Used by:
Cause: The device data referred to by a placing sequence does not exist.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F027
Display: This program M/C type is not supported
Used by:
Cause: The machine type specified in the production program is not supported.
Remedy: Correct the machine type.
------------------------------
Code: 2100F028
Display: Not found '+' option
Used by:
Cause: The '+' option was not specified at start-up.
Remedy: Contact Fuji.
------------------------------
Code: 2100F029
Display: Undefined device part name
Used by:
Cause: The part data name is not specified for a component.
Remedy: Correct the appropriate data.
------------------------------