FUJI错误代码查询.pdf - 第1981页
Display: No used Cartridge. Used by: Cause: A feeder name which is not registered under station data in the machine type table is in Part data. Remedy: Enter the feeder names which are registered under station data in th…
Used by:
Cause: The nozzle assignment file name has not been entered in the input program.
Remedy: Using the editor enter the nozzle assignment file name in the program.
------------------------------
Code: 2100792F
Display: Not get nozzle size
Used by:
Cause: An error occurred while obtaining the nozzle size for each part from Part data and the nozzle
assignment table.
Remedy: Using the editor edit the Part data and nozzle assignment table to ensure that the Part data
nozzle sizes are in the nozzle assignment table.
------------------------------
Code: 21007930
Display: Same deviice comment entry in PST file.
Used by:
Cause: In the PST file there is a device comment with the same name.
Remedy: Edit the permanent set table using the editor command to ensure that there are no duplicated
device comment entries.
------------------------------
Code: 21007931
Display: No entry Cartridge name.
Used by:
Cause: The feeder name is not in the permanent set table.
Remedy: Enter the feeder name in the permanent set table.
------------------------------
Code: 21007932
Display: Abnormal device number in PST file.
Used by:
Cause: There is an abnormal device number in the permanent set table (PST).
Remedy: Edit the PST using the editor command to ensure that the device numbers in the PST are less
than the maximum (140).
------------------------------
Code: 21007933
Display: Abnormal device comment in PST file.
Used by:
Cause: There is an abnormal device comment in the permanent set table.(PST)
Remedy: Edit the PST using the editor command to ensure that all device comments have been entered.
------------------------------
Code: 21007934
Display: Position already used.
Used by:
Cause: A position specified in the permanent set table (PST) is already in use.
Remedy: Edit the PST to ensure that no device numbers are duplicated.
------------------------------
Code: 21007935
Display: Not generate cartridge name.
Used by:
Cause: An error occurred when the feeder names were automatically generated.
Remedy: Edit the Part data.
------------------------------
Code: 21007936
第 1980 页
Display: No used Cartridge.
Used by:
Cause: A feeder name which is not registered under station data in the machine type table is in Part
data.
Remedy: Enter the feeder names which are registered under station data in the machine type table in Part
data.
------------------------------
Code: 21007937
Display: Not set cartridge name.
Used by:
Cause: The feeder name cannot be obtained from Part data.
Remedy: Enter the feeder name in Part data.
------------------------------
Code: 21007938
Display: Not set nozzle size.
Used by:
Cause: An error occurred while checking the nozzle size for each part in Part data and the nozzle
assignment table.
Remedy: Check that the nozzle sizes set in Part data are in the nozzle assignment table.
------------------------------
Code: 21007939
Display: Next device chain over 30 device.
Used by:
Cause: The next device chain is over 30 devices.
Remedy: Edit the program using the editor to ensure that the next device chain returns to the original
device within 30 devices.
------------------------------
Code: 2100793A
Display: Not found next device.
Used by:
Cause: There is no next device.
Remedy: Edit the program using the editor to ensure that the next device chain returns to the original
device.
------------------------------
Code: 2100793B
Display: Station over.
Used by:
Cause: Because of a "station over" condition the feeders cannot be assigned.
Remedy: Reduce the number of feeders in the program.
------------------------------
Code: 2100793C
Display: Not get Occupancy data.
Used by:
Cause: The machine type table occupancy data cannot be obtained.
Remedy: Re-install machine type table.CP6.
------------------------------
Code: 2100793D
Display: Not get Slot info data.
Used by:
Cause: The machine type table slot information data could not be obtained.
Remedy: Re-install machine type table.CP6.
第 1981 页
------------------------------
Code: 2100793E
Display: Parts height regulation over.
Used by:
Cause: The part height exceeds the maximum value (6 mm).
Remedy: Edit the Part data to ensure that the part height does not exceed the maximum value.
------------------------------
Code: 2100793F
Display: Different cartridge name in Input file and Fix apoint file.
Used by:
Cause: An error occurred when assigning fixed feeders.
Remedy: Edit to ensure that the feeder names in the program and the fixed file are the same.
------------------------------
Code: 21007940
Display: Input file name is too long.
Used by:
Cause: The input file name is too long.
Remedy: The input file name should be within 23 characters.
------------------------------
Code: 21007941
Display: Output file name is too long.
Used by:
Cause: The output file name is too long.
Remedy: The output file name should be within 23 characters, including (.o) when the file name is
abbreviated.
------------------------------
Code: 21007942
Display: PST file name is too long.
Used by:
Cause: The permanent set table (PST) file name is too long. The PST file name should be within 23
characters.
Remedy: Set the permanent set table file name to 23 characters or less.
------------------------------
Code: 21007943
Display: Base program file name is too long.
Used by:
Cause: The base program file name is too long.
Remedy: The base program file name should be within 23 characters.
------------------------------
Code: 21007944
Display: Illegal format at MTT file.
Used by:
Cause: The machine type table (MTT) file format is unsuitable.
Remedy: Re-install MTT.CP6.
------------------------------
Code: 21007945
Display: Make not mount sequence.
Used by:
Cause: An error occurred when mounting sequences were being prepared for the output program.
Remedy: Reboot the MCS.
------------------------------
第 1982 页