Code: 12074?16 Display: "PMC?(ICM,SCU?) Error Code:********" (QP2) "RAM Check Error" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: RAM check error (axis common e…
------------------------------
Code: 12074?11
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"NMI(PMC)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: NMI (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?12
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"0 Divide" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Zero division (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?13
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Overflow(PMC)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Overflow (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?14
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"INT_XX(PMC)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: INT_XX (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?15
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"2-Port RAM Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: 2-port RAM interrupt error (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
第 771 页
Code: 12074?16
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"RAM Check Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: RAM check error (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?17
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"2-Port RAM Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: 2-port RAM error (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?18
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Total Check" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Total check (axis common error data).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12074?19
Display: "PM?? ERROR [Code:12074?19]" (value replacing "??" is module number;value replacing "?" is
module number.
PM?? ERROR Code:******** (QP132)
"Z-axis sensor error"(QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Z-axis Sensor alarm(Discrepency in Z-axis conditions).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Ensure that the Z-axis'air cylinder as well as the raised and lowered position sensors are
operating normally.
------------------------------
Code: 12074?1A
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Position NG (Z not up-end)" (QP2)
PM?? ERROR Code:******** (QP132)
"Nozzle upper limit error"(QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: There is a Z-axis position error (the Z-axis is not at the raised position).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 772 页
Remedy: Check that the Z-axis operates normally. Check that the Z-axis speed reduction point sensor is
operating normally.
------------------------------
Code: 12074?1B
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Failed to reset servo amp." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Failed to clear servo amp error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button again.
------------------------------
Code: 12074?1C
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Feeder set error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A tape leaf error has been detected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Make sure the feeder is properly set. Make sure the tape leaf detection sensor is functioning
normally.
------------------------------
Code: 12074?1D
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Plcg. pressure sensor error" (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP341,QP351
Cause: The placing pressure confirmation sensor did not turn on when the nozzle descended to the
provisional position for pressure control.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Placing pressure check sensor did not come ON. Sensor is damaged or position of sensor is
incorrect.(QP3)
Remedy: Check whether the placing pressure confirmation sensor is functioning normally and whether it
is attached at the correct position.(QP2)
Check sensor position.(QP3)
------------------------------
Code: 12074?20
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (X)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis command pulse error (outside software limit range).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The X-axis movement target position exceeds the limit values specified in the Proper data.
Check the movement target value and the Proper data values.
------------------------------
Code: 12074?21
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Command Out of Soft Lim (Y)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
第 773 页