FUJI错误代码查询.pdf - 第694页

------------------------------ Code: 12068C86 Display: MPRXY2 <sub-slot number> data error! Used by: QP3,NP2 Cause: Remedy: Check if the <sub-slot number> for the MPRXY2 command falls outside the 1-2 range. -…

100%1 / 5282
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPOSIT command exceeds the number of available slots.
------------------------------
Code: 12068C72
Display: MPOSIT <sub-slot> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot> for the MPOSIT command has been set to a value other than 1 or 2.
------------------------------
Code: 12068C73
Display: MPOSIT <offset> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <offset> for the MPOSIT command exceeds the travel limits for the TY-axis.
------------------------------
Code: 12068C80
Display: MPRXY1 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY1 command falls outside the 0-2 range.
------------------------------
Code: 12068C81
Display: MPRXY1 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY1 command falls outside the 1-10 range.
------------------------------
Code: 12068C82
Display: MPRXY1 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY1 command falls outside the 1-2 range.
------------------------------
Code: 12068C83
Display: MPRXY1 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY1 command falls outside the 0-1 range.
------------------------------
Code: 12068C84
Display: MPRXY2 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY2 command falls outside the 0-2 range.
------------------------------
Code: 12068C85
Display: MPRXY2 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY2 command falls outside the 11-20 range.
第 693 页
------------------------------
Code: 12068C86
Display: MPRXY2 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY2 command falls outside the 1-2 range.
------------------------------
Code: 12068C87
Display: MPRXY2 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY2 command falls outside the 0-1 range.
------------------------------
Code: 12068C88
Display: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
------------------------------
Code: 12068C89
Display: MPRXY3 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY3 command falls outside the 21-30 range.
------------------------------
Code: 12068C8A
Display: MPRXY3 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY3 command falls outside the 1-2 range.
------------------------------
Code: 12068C8B
Display: MPRXY3 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY3 command falls outside the 0-1 range.
------------------------------
Code: 12068C8C
Display: MPRXY4 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY4 command falls outside the 0-2 range.
------------------------------
Code: 12068C8D
Display: MPRXY4 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY4 command falls outside the 31-40 range.
------------------------------
Code: 12068C8E
Display: MPRXY4 <sub-slot number> data error!
第 694 页
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY4 command falls outside the 1-2 range.
------------------------------
Code: 12068C8F
Display: MPRXY4 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY4 command falls outside the 0-1 range.
------------------------------
Code: 12068C90
Display: MPRXY5 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY5 command falls outside the 0-2 range.
------------------------------
Code: 12068C91
Display: MPRXY5 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY5 command falls outside the 41-50 range.
------------------------------
Code: 12068C92
Display: MPRXY5 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY5 command falls outside the 1-2 range.
------------------------------
Code: 12068C93
Display: MPRXY5 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY5 command falls outside the 0-1 range.
------------------------------
Code: 12068CA0
Display: MPRZ <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRZ command falls outside the 0-1 range.
------------------------------
Code: 12068CA1
Display: MPRZ <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRZ command falls outside the 1-2 range.
------------------------------
Code: 12068CB0
Display: MPRORG <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRORG command falls outside the 0-2 range.
第 695 页