FUJI错误代码查询.pdf - 第1697页

------------------------------ Code: 1D39000E Display: Same as code. Used by: Cause: A lead is too long. Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection. Leads ca…

100%1 / 5282
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D390007
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D390008
Display: Same as code.
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D390009
Display: Same as code.
Used by:
Cause: A sufficient number of leads could not be found.
Remedy: Check the lead quantity and the part supply direction. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D39000B
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D39000C
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D39000D
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
第 1696 页
------------------------------
Code: 1D39000E
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D39000F
Display: Same as code.
Used by:
Cause: Processing error.
Remedy: Check the part's shape. Check for a missing part.
------------------------------
Code: 1D390010
Display: Same as code.
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the lead quantity. Lead thickness is critical to lead detection. Leads
can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part data. A
variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D390011
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the part supply direction.
------------------------------
Code: 1D390012
Display: Same as code.
Used by:
Cause: The leads on the opposite side are too long. The part body is too large.
Remedy: Check the part's size. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D3A0001
Display: Same as code.
Used by:
Cause: There is an omission in the Part data.
Remedy: Enter the necessary data.
------------------------------
Code: 1D3A0003
Display: Same as code.
Used by:
Cause: The camera cannot acquire a part image. The part is too large.
Remedy: Check the camera, video processing board, cable, and focus. Check the part. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
第 1697 页
------------------------------
Code: 1D3A0004
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Inspect the part for missing leads, and check lead width. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D3A0005
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D3A0006
Display: Same as code.
Used by:
Cause: Only one lead could be found.
Remedy: Inspect the part for missing leads, and check the part supply direction. Lead thickness is
critical to lead detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the
value specified in the Part data. A variety of errors may occur if this range is exceeded. Check the leads
and the CCD level.
------------------------------
Code: 1D3A0007
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D3A0008
Display: Same as code.
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D3A0009
Display: Same as code.
Used by:
Cause: A sufficient number of leads could not be found.
Remedy: Check the lead quantity and the part supply direction. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
第 1698 页