FUJI错误代码查询.pdf - 第2285页

Remedy: Check the settings for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER" in the mark data file referred to in the production program. ---…

100%1 / 5282
Code: 52??1201
Display: Mark data file is being used.
Used by:
Cause: The mark data file referred to in the specified production program is being used. This report is
made if the mark data and production program are in different files, the mark data referred to in the
production program is required in the applicable machine type and the above error is detected.
Remedy: Wait until the file is not being used and then re-execute the command.
------------------------------
Code: 52??1202
Display: No authority for mark data file.
Used by:
Cause: There is no access authority for the mark data file referred to in the specified production
program. This report is made if the mark data and production program are in different files, the mark
data referred to in the production program is required in the applicable machine type and the above error
is detected.
Remedy:
------------------------------
Code: 52??1203
Display: Mark data file cannot be opened.
Used by:
Cause: The mark data file referred to in the specified production program cannot be opened. This report
is made if the mark data and production program are in different files, the mark data referred to in the
production program is required in the applicable machine type and the above error is detected.
Remedy:
------------------------------
Code: 52??1204
Display: No "UNIT", "STRUCT" in mark data file.
Used by:
Cause: There is no "UNIT", "STRUCT" in the mark data file referred to in the specified production
program. This report is made if the mark data and production program are in different files, the mark
data referred to in the production program is required in the applicable machine type and the above error
is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the mark data file referred to in the production
program.
------------------------------
Code: 52??1205
Display: Mark data file structure error.
Used by:
Cause: A format error was detected in "UNIT", "STRUCT" in the mark data file referred to in the specified
production program. This report is made if the mark data and production program are in different files,
the mark data referred to in the production program is required in the applicable machine type and the
above error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the mark data file referred to in the production
program.
------------------------------
Code: 52??1206
Display: Not mark data file.
Used by:
Cause: The mark data file referred to in the specified production program is not a mark data file. This
report is made if the mark data and production program are in different files, the mark data referred to in
the production program is required in the applicable machine type and the above error is detected.
第 2284 页
Remedy: Check the settings for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER" in
the mark data file referred to in the production program.
------------------------------
Code: 52??1207
Display: Mark file read error.
Used by:
Cause: A read error occurred in the mark data file referred to in the specified production program. This
report is made if the mark data and production program are in different files and the above error is
detected.
Remedy: Check the mark data file referred to in the production program.
------------------------------
Code: 52??1210
Display: "FILETYPE" not entered in the mark data file.
Used by:
Cause: "FILETYPE" is not entered in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified mark data
file.
Remedy: "FILETYPE" is a mandatory item.
------------------------------
Code: 52??1211
Display: "FILESTRUCT" not registered in the mark data file.
Used by:
Cause: "FILESTRUCT" is not registered in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified
mark data file.
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 52??1212
Display: No "UNIT", "MARK" in mark data file or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: The mark data file referred to in the specified production program was read and "UNIT" ,"MARK"
was not found or "UNIT", "MARK" does not follow the correct unit. This report is made if the mark data
and production program are in different files, the mark data referred to in the production program is
required in the applicable machine type and the above error is detected. When downloading, the mark
data assumes its default values.
Remedy: Check the settings for "UNIT", "MARK" in the mark data file referred to in the production
program. Also check the setting for the "UNIT" line located prior to "UNIT", "MARK".
------------------------------
Code: 52??1213
Display: No "UNIT", "MARK" - "BLOCK" -"HEADER-" in the mark data file.
Used by:
Cause: The mark data file referred to in the specified production program was read and "BLOCK",
"HEADER-" in "UNIT", "MARK" was not found. This report is made if the mark data and production
program are in different files, the mark data referred to in the production program is required in the
applicable machine type and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "HEADER-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1214
Display: No "UNIT", "MARK" - "BLOCK", "MARKDT-" in the mark data file.
Used by:
Cause: The mark data file referred to in the specified production program was read and "BLOCK",
"MARKDT-" in "UNIT", "MARK" was not found. This report is made if the mark data and production
第 2285 页
program are in different files, the mark data referred to in the production program is required in the
applicable machine type and the above error is detected.
Remedy: Check the setting for "UNIT", "MARK" - "BLOCK", "MARKDT-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1215
Display: "UNIT", "MARK" - "BLOCK", "MARKDT-" multiply defined for same mark.
Used by:
Cause: "UNIT", "MARK" in the specified production program was read and "BLOCK", "MARKDT-" was
multiply defined for the same mark. This report is made if the mark data and production program are in
the same file and the above error is detected. When downloading, the first "BLOCK", "MARKDT-" is valid.
Remedy: At "MARKTYPE" in "UNIT", "MARK" - "BLOCK", "HEADER" in the production program, check that
the same mark is not multiply defined.
------------------------------
Code: 52??1216
Display: Mark data file "UNIT", "MARK" - "BLOCK", "HEADER-" format error.
Used by:
Cause: The mark data file referred to in the specified production program was read and an error detected
in the format of "BLOCK", "HEADER-" in "UNIT", "MARK. This report is made if the mark data and
production program are in different files, the mark data referred to in the production program is required
in the applicable machine type and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" - "BLOCK", "HEADER-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1217
Display: Mark data file "UNIT", "MARK" - "BLOCK", "MARKDT-" format error.
Used by:
Cause: The mark data file referred to in the specified production program was read and an error detected
in the format of "BLOCK", "MARKDT-" in "UNIT", "MARK. This report is made if the mark data and
production program are in different files, the mark data referred to in the production program is required
in the applicable machine type and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" - "BLOCK", "MARKDT-" in the mark data file referred to in
the production program.
------------------------------
Code: 52??1220
Display: No "UNIT", "MARK" or "UNIT", "MARK" is not at the correct position.
Used by:
Cause: "UNIT", "MARK" was not found in the specified production program or "UNIT", "MARK" does not
follow the correct unit. This report is made if the mark data and production program are in the same file
and the above error is detected.
Remedy: Check the settings in "UNIT", "MARK" in the production program. Also check the setting for the
"UNIT" line prior to "UNIT", "MARK".
------------------------------
Code: 52??1221
Display: There is no "BLOCK" in "UNIT", "MARK".
Used by:
Cause: No "BLOCK" was found in "UNIT", "MARK" in the specified production program. This report is
made if the mark data and production program are in the same file and the above error is detected. The
relevant unit is ignored when downloading.
Remedy: Check the "UNIT", "MARK" setting in the production program.
------------------------------
第 2286 页