FUJI错误代码查询.pdf - 第2127页
Display: There are sequences on the same board with the same mark number. Used by: Cause: A fiducial mark reading sequence exists which has duplicate mark numbers within a single board. Remedy: Revise either the "Bo…
Code: 2300E003
Display: Data contains invalid characters. [item name].
Used by:
Cause: An illegal character was entered.
Remedy: Select the setting item where the error occurred to display the illegal character at the bottom of
the window, then revise the data accordingly.
------------------------------
Code: 2300E004
Display: No data exists. [item name].
Used by:
Cause: No setting has been specified.
Remedy: Specify a setting.
------------------------------
Code: 2300E102
Display: 'Position X' exceeds the range of the panel.
Used by:
Cause: The sequence data's X-coordinate is off the panel.
Remedy: Specify an X-coordinate which is within the panel size range.
------------------------------
Code: 2300E103
Display: 'Position Y' exceeds the range of the panel.
Used by:
Cause: The sequence data's Y-coordinate is off the panel.
Remedy: Specify an Y-coordinate which is within the panel size range.
------------------------------
Code: 2300E104
Display: Stage number has not been specified.
Used by:
Cause: The stage number has been set.
Remedy: Specify the stage number of the part to be mounted.
------------------------------
Code: 2300E105
Display: Slot number has not been specified.
Used by:
Cause: The slot number has not been set.
Remedy: Specify the slot number of the part to be mounted.
------------------------------
Code: 2300E106
Display: No data has been specified in stage number/slot number.
Used by:
Cause: No setting data exists for the stage number and slot number specified in the sequence data.
Remedy: Either specify settings for the stage number and slot number in the feeder setup data, or specify
a stage number and slot number for which setting data already exists.
------------------------------
Code: 2300E107
Display: Mark number has not been specified.
Used by:
Cause: The mark number in the fiducial mark reading sequence is set as "0".
Remedy: Specify a mark number setting other than "0".
------------------------------
Code: 2300E108
第 2126 页
Display: There are sequences on the same board with the same mark number.
Used by:
Cause: A fiducial mark reading sequence exists which has duplicate mark numbers within a single
board.
Remedy: Revise either the "Board No." or "Mark No." in the sequence data.
------------------------------
Code: 2300E109
Display: Main mark number has not been set.
Used by:
Cause: The main mark number in the part placement sequence is set as "0".
Remedy: Specify a main mark number setting other than "0".
------------------------------
Code: 2300E10A
Display: Sub mark number has not been set.
Used by:
Cause: The sub-mark number in the part placement sequence is set as "0".
Remedy: Specify a sub-mark number setting other than "0".
------------------------------
Code: 2300E10B
Display: The main mark and sub mark numbers are identical.
Used by:
Cause: The same setting value is specified for both the main mark number and the sub-mark number in
the part placement sequence.
Remedy: Specify setting values so that the main mark number and sub-mark number are different.
------------------------------
Code: 2300E10C
Display: The fiducial mark sequence for the mark number set as the main mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
main mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified main mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10D
Display: The fiducial mark sequence for the mark number set as the sub mark cannot be found.
Used by:
Cause: A fiducial mark reading sequence which contains the specified (in the part placement sequence)
sub-mark number cannot be found.
Remedy: Set the fiducial mark reading sequence for the specified sub-mark number to occur before the
part placement sequence.
------------------------------
Code: 2300E10E
Display: Board skip settings of '0' and '1' have both been specified in the sequence data for the same
board.
Used by:
Cause: Sequence data with and without board skip settings exist for the same board.
Remedy: Correct the sequence data so that all sequences for the same board have the same board skip
settings.
------------------------------
Code: 2300E10F
Display: Feeder skip settings of '0' and '1' have both been specified in the sequence data for the same
第 2127 页
stage and slot number.
Used by:
Cause: Sequence data with and without feeder skip settings exist for the same stage/slot number.
Remedy: Correct the sequence data so that all sequences for the same stage/slot number have the same
feeder skip settings.
------------------------------
Code: 2300E110
Display: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Used by:
Cause: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Remedy: Correct the sequence data so that the total number of board skip mark read sequences
(Sequence type:B) and fiducial mark read sequences (Sequence type:F) is 255 or less.
------------------------------
Code: 2300E111
Display: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Used by:
Cause: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Remedy: Specify a "Sequence Comment" sequence that applies to the same board as that of the "Place
Before" sequence.
The "Place Before" sequence is ignored where the "Sequence Comment" sequence does not apply to the
same board.
------------------------------
Code: 2300E112
Display: The same name has been allocated to "Place Before" and "Sequence Comment".
Used by:
Cause: The same name has been allocated to the "Place Before" and "Sequence Comment" sequences.
Remedy: Specify different names for the "Place Before" and "Sequence Comment" sequences.
------------------------------
Code: 2300E113
Display: Duplicate "Sequence Comment" sequences exist for the same board.
Used by:
Cause: Duplicate "Sequence Comment" sequences exist for the same board.
Remedy: Create sequences so that "Sequence Comment" sequences are not duplicated for the same
board.
------------------------------
Code: 2300E114
Display: The "Place Before" sequence order is incorrect.
Used by:
Cause: The "Place Before" sequence order is incorrect.
Remedy: Change the "Place Before" sequence order so that the "Place Before" sequence is positioned
before the "Sequence Comment" sequence.
------------------------------
Code: 2300E115
Display: Mark data does not exist for the specified mark name.
Used by:
Cause: Either the mark name is input incorrectly in the sequence data, or the mark data does not exist.
Remedy: Check the mark data. If mark data does exist, then check the mark name in the sequence data.