FUJI错误代码查询.pdf - 第1566页
------------------------------ Code: 1D25D080 Display: Used by: Cause: The part pickup slippage was too large (Y direction). Remedy: Check how the parts are being supplied. ------------------------------ Code: 1D25E??? D…
data.
------------------------------
Code: 1D25C2??
Display:
Used by:
Cause: A lead could not be detected on the right side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25C3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
第 1565 页
------------------------------
Code: 1D25D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D25E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D25F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D260002
Display:
Used by:
Cause: Unable to pick part.
Remedy: Replenish the part supply.
------------------------------
Code: 1D264001
Display:
Used by:
Cause: Process error.
Remedy: A part image could not be taken. The shape of the part was wrong. The nozzle was too small
and the field of vision could not be secured. Check the camera, vision processing borad, cable and focus.
Make sure foreign matter is not stuck to the parts.
------------------------------
Code: 1D264002
Display:
Used by:
Cause: Unable to pick part.
Remedy: Replenish the part supply.
------------------------------
Code: 1D264003
Display: 1D264003
Used by:
Cause: The bumper could not be found. The setting made for the direction item in part data and the
actual orientation of the part are different.
Remedy: Check the supply direction of the part.
------------------------------
Code: 1D26401E
Display:
Used by:
Cause: The pitch of the two outermost leads is too small.
第 1566 页
Remedy: Check the number of leads on the part, the pitch and the lead width.
------------------------------
Code: 1D26401F
Display:
Used by:
Cause: The pitch of the two outermost leads is too small.
Remedy: Check the number of leads on the part, the pitch and the lead width.
------------------------------
Code: 1D268002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D268100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D268110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D268111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D268112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D268113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D268114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.