FUJI错误代码查询.pdf - 第688页
Cause: Remedy: Turn the TY-axis travel permit input and the tray supply input both off, and move the TY-axis to a position where one of the inputs turns on. ------------------------------ Code: 12068801 Display: TZ-axis …
Used by: QP3,NP2
Cause:
Remedy: Check if the lifer upper limit sensor is on, or if the remover lower limit sensor is off. Also check if
there is a delay in lifter ascent.
------------------------------
Code: 12068611
Display: Remover descent error!
Used by: QP3,NP2
Cause:
Remedy: Check if the lifter upper limit sensor is off, or if the lower limit sensor is on. Also check if there is
a delay in lifter descent.
------------------------------
Code: 12068612
Display: Remover chucking error!
Used by: QP3,NP2
Cause:
Remedy: Check if the remover's chucking sensor is on. Also check if there is a delay in the chucking
motion.
------------------------------
Code: 12068613
Display: Remover release cycle error!
Used by: QP3,NP2
Cause:
Remedy: Check if the remover's chucking sensor is off. Also check if there is a delay in the remover's
release motion.
------------------------------
Code: 12068614
Display: Remover hose ascent cycle error.
Used by: QP3,NP2
Cause:
Remedy: The remover hose was raised, but the upper limit sensor did not turn off within the required 3
second time period.
------------------------------
Code: 12068615
Display: Remover hose descent cycle error.
Used by: QP3,NP2
Cause:
Remedy: The remover hose was lowered, but the lower limit sensor did not turn off within the required 3
second time period.
------------------------------
Code: 12068616
Display: Clamper cylinder cycle error.
Used by: QP3,NP2
Cause: Even though the clamper cylinder operates, the status of the clamp cylinder open limit sensor
does not change.
Remedy: Check the operation of the clamper cylinder, or check that the clamp cylinder open limit sensor
triggers correctly.
------------------------------
Code: 12068800
Display: TZ-axis interlock error (TY-axis intermediate position).
Used by: QP3,NP2
第 687 页
Cause:
Remedy: Turn the TY-axis travel permit input and the tray supply input both off, and move the TY-axis to
a position where one of the inputs turns on.
------------------------------
Code: 12068801
Display: TZ-axis interlock error (no tray received).
Used by: QP3,NP2
Cause:
Remedy: Check if the drawer is triggering the tray supply sensor.
------------------------------
Code: 12068802
Display: TZ-axis interlock error (Y-axis at retract limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its retract limit (TY-axis travel permit sensor on).
------------------------------
Code: 12068803
Display: TZ-axis interlock error (TY-axis at advance limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its advance limit (tray pick-up sensor on).
------------------------------
Code: 12068804
Display: TZ-axis interlock error.
Used by: QP3,NP2
Cause:
Remedy: Check if the clamper cylinder open limit sensor is on.
------------------------------
Code: 12068810
Display: TY-axis interlock error (advanced).
Used by: QP3,NP2
Cause:
Remedy: Check if the tray pick-up sensor is on.
------------------------------
Code: 12068811
Display: TY-axis interlock error (retracted).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis retract permit sensor is on.
------------------------------
Code: 12068812
Display: TY-axis interlock error (TZ-axis position undefined).
Used by: QP3,NP2
Cause:
Remedy: Check if the TZ-axis is at tray shuttling height.
------------------------------
Code: 12068820
Display: Tray rejection error!
Used by: QP3,NP2
Cause:
Remedy: Check if the tray has been dropped during transfer to the reject position.
第 688 页
------------------------------
Code: 12068A00
Display: Failed to clear emergency stop status.
Used by: QP3,NP2
Cause:
Remedy: Check the EMERGENCY STOP button and the safety door.
------------------------------
Code: 12068A01
Display: Operation is being performed from the inching box.
Used by: QP3,NP2
Cause:
Remedy: Check if the inching input is on.
------------------------------
Code: 12068A02
Display: Failed to clear the reset status.
Used by: QP3,NP2
Cause:
Remedy: Awaiting reset command. Check if an operation instruction is being issued.
------------------------------
Code: 12068A04
Display: Resupplying parts.
Used by: QP3,NP2
Cause:
Remedy: Press the parts set switch.
------------------------------
Code: 12068A05
Display: Slot number not specified.
Used by: QP3,NP2
Cause:
Remedy: Move the extended drawer back into the magazine.
------------------------------
Code: 12068A06
Display: MTU command processing error.
Used by: QP3,NP2
Cause: While the MTU was executing a command, another command was issued bythe machine resulting
in a command processing error.
Remedy: Press READY ON to clear the error condition, and restart processing.If this type of error occurrs
frequently upgrade the MTU software.
------------------------------
Code: 12068A07
Display: Sensor measurement error.
Used by: QP3,NP2
Cause: Tray height measurement failed.
Remedy: Verify that a measurement jig is set in position and that the tray height check sensor is
functioning normally.
------------------------------
Code: 12068A08
Display: Sensor measurement data error.
Used by: QP3,NP2
Cause: Tray height measurement data error.
Remedy: Measure the height of the tray height confirmation sensor.
第 689 页