FUJI错误代码查询.pdf - 第1657页

Display: Same as code. Used by: Cause: No leads could be found on the lower side. Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. ------------------------------ Code: 1D…

100%1 / 5282
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B2??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the lower side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B3??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the lower side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B4??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the right side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B5??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the right side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B6??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the upper side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33B7??
Display: Same as code.
Used by:
Cause: A lead that should exist has not been found on the upper side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33C0??
Display: Same as code.
Used by:
Cause: No leads could be found on the left side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33C1??
第 1656 页
Display: Same as code.
Used by:
Cause: No leads could be found on the lower side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33C2??
Display: Same as code.
Used by:
Cause: No leads could be found on the right side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33C3??
Display: Same as code.
Used by:
Cause: No leads could be found on the upper side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D33C4??
Display: Same as code.
Used by:
Cause: The left edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D33C5??
Display: Same as code.
Used by:
Cause: The lower edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D33C6??
Display: Same as code.
Used by:
Cause: The right edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D33C7??
Display: Same as code.
Used by:
Cause: The upper edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D33D000
Display: Same as code.
Used by:
Cause: The pickup position error (in the X direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
第 1657 页
Code: 1D33D080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D33D100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D33E???
Display: Same as code.
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D33F???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D340002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D344006
Display: Same as code.
Used by:
Cause: The part's inclination is execessive.
Remedy: Check the part's shape and supply direction.
------------------------------
Code: 1D344041
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D344042
Display: Same as code.
第 1658 页