FUJI错误代码查询.pdf - 第603页

Cause: Reading of the feeder ID failed. Remedy: Check the ID of the feeder in the slot where the error occurred. Also, verify that the feeder ID reader is connected properly. ------------------------------ Code: 1206102F…

100%1 / 5282
Remedy: Verify that the correct slot number is specified in the production program. Alternatively, verify
that the device offset settings are correctly specified in Part data and Proper data.
------------------------------
Code: 12061027
Display: The D1-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The D1-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that the correct slot number is specified in the production program. Alternatively, verify
that the device offset settings are correctly specified in part data and Proper data.
------------------------------
Code: 12061028
Display: The D2-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The D2-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Remedy: Verify that the correct slot number is specified in the production program. Alternatively, verify
that the device offset settings are correctly specified in Part data and Proper data.
------------------------------
Code: 12061029
Display: The D2-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The D2-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that the correct slot number is specified in the production program. Alternatively, verify
that the device offset settings are correctly specified in Part data and Proper data.
------------------------------
Code: 1206102A
Display: The NZ-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The NZ-axis target position exceeds the plus-limit of the travel range specified in Proper data.
Remedy: Verify that a suitable pickup height offset is specified in Part data.
------------------------------
Code: 1206102B
Display: The NZ-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The NZ-axis target position exceeds the minus-limit of the travel range specified in Proper data.
Remedy: Verify that a suitable pickup height offset is specified in Part data.
------------------------------
Code: 1206102C
Display: Head A detection error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Head A detection error.
Remedy: Check to see if the Head A sensor is operating properly.
------------------------------
Code: 1206102D
Display: Head A detection sensor error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The Head A detection sensor is not operating properly.
Remedy: Check the sensor wiring. If the wiring is OK, replace the sensor.
------------------------------
Code: 1206102E
Display: Feeder ID reading error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
第 602 页
Cause: Reading of the feeder ID failed.
Remedy: Check the ID of the feeder in the slot where the error occurred. Also, verify that the feeder ID
reader is connected properly.
------------------------------
Code: 1206102F
Display: Feeder type error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The wrong feeder is in the slot specified by the production program.
Remedy: Set the correct feeder in the slot where the error occurred.
------------------------------
Code: 12061030
Display: Feeder ID setting transmission error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: An error occurred in the feeder ID reader's setting data transmission.
Remedy: Check to see if the feeder ID reader is connected properly.
------------------------------
Code: 12061031
Display: Cam axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Cam axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061032
Display: X-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: X-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061033
Display: Y-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Y-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061034
Display: Z-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Z-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061035
Display: PQ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: PQ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061036
Display: FQ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: FQ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
第 603 页
------------------------------
Code: 12061037
Display: RQ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: RQ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061038
Display: D1-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D1-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061039
Display: D2-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D2-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103A
Display: NZ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: NZ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103B
Display: D1-axis interlock.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D1-axis operation will result in interference.
Remedy: Check to see if the pallet stopper on the Stage 1 side is off. Check to see if the Stage 1 pallet
transport sensor is off. Check to see if the Stage 1 pallet DOWN limit sensor is on.
------------------------------
Code: 1206103C
Display: D2-axis interlock.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D2-axis operation will result in interference.
Remedy: Check to see if the pallet stopper on the Stage 2 side is off. Check to see if the Stage 2 pallet
transport sensor is off. Check to see if the Stage 2 pallet DOWN limit sensor is on.
------------------------------
Code: 1206103D
Display: System processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The servo gain parameter management table number for the servo axis in question is incorrect.
Remedy: When this error occurs, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103F
Display: Sequencer communication error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Communication is not possible due to a connection error with the feeder verification sensor
monitoring sequencer.
Remedy: Ensure that the communication cable is properly connected, and that the connection port
第 604 页