Code: 23040106 Display: The Alt. Feeder number must be set to a different slot. Set the final slot in the loop to point back to the first slot in the loop. Used by: Cause: An Alt. Feeder number has been set for the same …
Code: 2304004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop? .
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230400A3
Display: Optimization cannot be performed if there are less than two active fiducial marks.
Used by:
Cause: Optimization cannot be performed for programs containing less than two active fiducial marks,
including skipped marks.
Remedy: Add two or more active fiducial mark sequences to the program.
------------------------------
Code: 230400A4
Display: Optimization cannot be performed because no valid placement sequences exist.
Used by:
Cause: Optimization cannot be performed because all placement sequences are skipped.
Remedy: The program must contain at least one placement sequence that is not to be skipped.
------------------------------
Code: 23040102
Display: Only 8mm and 12mm feeders can be handled by the XP-141E.
Used by:
Cause: The tape width indicated in Tape Width (PARTS/PACKLS-/TAPEWIDTH) or Packaging Name
(PARTS/HEADER/CMPNAME) is neither 8mm nor 12mm. This feeder cannot be mounted on the XP-141E.
Remedy: There is an error with the tape width specified in the part data of the program file. Correct the
error.
------------------------------
Code: 23040105
Display: Unused Nozzle(s) exist in the Revolver. Continue?
Used by:
Cause: Unused nozzle(s) exist in the revolver, or unusable nozzles are set in the revolver.
Remedy: Optimize with 乬Configure feeders automatically乭, or revise the nozzle array in the program file
or with manual input.
------------------------------
第 2149 页
Code: 23040106
Display: The Alt. Feeder number must be set to a different slot. Set the final slot in the loop to point back
to the first slot in the loop.
Used by:
Cause: An Alt. Feeder number has been set for the same slot.
Remedy: In the program file's feeder setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 23050003
Display: The tape width is outside the specifications or is zero.
Used by:
Cause: The Packaging Name (PARTS/HEADER/CMPNAME) or the Tape Width (PARTS/PACKLS-
/TAPEWIDTH) is outside the specifications or is zero. For Packaging Name, one of the following types
must be specified: E08xx, E12xx, E16xx, E24xx, E32xx, J32xx, E44xx, E56xx, E72xx, E88xx. For Tape
Width, one of the following must be specified: 8, 12, 16, 24, 32, 44, 56, 72, 88.
Remedy: The tape width setting in the part data is incorrect. Check the file contents.
------------------------------
Code: 23050004
Display: Part Transport Speed is zero.
Used by:
Cause: Part Transport Speed (PARTS/ENVDT/XP241ENVDT-/PENSPD1) is zero.
Remedy: The Part transport speed setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 23050005
Display: A feeder or tray does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder or tray does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23050006
Display: Part data referred to by the sequence slot does not exist.
Used by:
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23050008
Display: No feeder or tray exists in the slot referenced by this skipped sequence (for skipped sequences
included in optimization).
Used by:
Cause: A feeder or tray does not exist in a sequence slot that contains board/feeder/sequence skip
settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2305000A
Display: No part data exists for the slot referenced by this skipped sequence (for skipped sequences
included in optimization).
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
第 2150 页
------------------------------
Code: 2305000B
Display: For the item [Interval of Mount Height in order from lowest to highest], an illegal value was input
for [High Density Circuit Board].
Used by:
Cause: At the Optimize Condition Settings screen, under the item [Interval of Mount Height in order from
lowest to highest], a the setting entered in [Mount in 0.1mm Intervals up to ***mm (High Density Circuit
Board)] is not a numeric value.
Remedy: Enter a numeric value.
------------------------------
Code: 2305000C
Display: For the item [Interval of Mount Height in order from lowest to highest], the input value for [High
Density Circuit Board] is out of range (0 to 2.0).
Used by:
Cause: At the Optimize Condition settings screen, under the item [Interval of Mount Height in order from
lowest to highest], the setting entered in [Mount in 0.1mm Intervals up to ***mm (High Density Circuit
Board)] is out of range (0 to 2.0).
Remedy: Enter a value within the input range.
------------------------------
Code: 2305000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the Alt. Feeder specified for the displayed stage - slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2305000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use feeder type] settings.
If unsuccessful, perform optimization using the [Alt. Feeders are Removed] setting.
If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 2305000F
Display: There are too many trays allocated to one pallet.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of trays allocated to one pallet exceeded the maximum tray slots.
Remedy: Firstly, try changing the [Arrange Trays on the Pallet] setting to [Give Priority to Number of Kinds
over Speed (Allots two part kinds to one pallet)].
If unsuccessful, perform optimization using the [Alt. Feeders are Removed] setting.
If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23050010
Display: A currently unused feeder has been fixed, however, no part data exists for that slot.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23050011