semi合集-English.pdf - 第1080页

SEMI E5-1104 © SEMI 1982, 2004 22 Name Format Description Values Where Used LIMITID 10 The identifier of a specific limit in the set of limits (as defined by UPPERDB and LOWERDB) for a variable to which the corresponding…

100%1 / 7923
SEMI E5-1104 © SEMI 1982, 2004 21
Name Format Description Values Where Used
HCACK 10 Host Command Parameter
Acknowledge Code, 1 byte
0 = Acknowledge, command has
been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is
invalid
4 = Acknowledge, command will
be performed with completion
signaled later by an event
5 = Rejected, Already in
Desired Condition
6 = No such object exists
7-63 Reserved
S2F42, F50
HOACK 11 Conveys whether the
corresponding handoff
activity succeeded (= True) or
failed (= False)
S4F31, F33
HOCANCELACK 51 Tells whether the cancel
ready message was accepted
or rejected
0 = Cancel Ready Accepted
1 = Atomic Transfer Unknown
2 = Cancel Ready Rejected -
Handoff Begun
S4F13
HOCMDNAME 20 Identifier for the handoff
command to be executed
S4F31
HOHALTACK 51 Tells whether the halt
command was accepted or
rejected
0 = Halt Accepted
1 = Atomic Transfer Unknown
2-63 Reserved
S4F41
IACDS 32, 52 Immediately After Command
Codes
Vector of all command codes
which defined command must
immediately succeed within the
same block.
S7F22
IBCDS 32, 52 Immediately Before
Command Codes
Vector of all command codes
which defined command must
immediately precede within the
same block.
S7F22
IDTYP 10 Id type
0 = Wafer ID
1 = Wafer Cassette ID
2 = Film Frame ID
>2 = Error
3-63 Reserved
S12F1, F3, F4,
F5, F7, F9, F11,
F13, F14, F15,
F16, F17, F18
INPTN 10, 51 A specialized version of PTN
indicating the InputPort.
S3F35
JOBACTION 20 Specifies the action for a
ReticleTransferJob
S3F35
LENGTH 3(), 5() Length of the service
program or process program
in bytes
S2F1;
S7F1, F29
LIMITACK 10 Acknowledgment code for
variable limit attribute set, 1
byte
1 = LIMITID does not exist
2 = UPPERDB > LIMITMAX
3 = LOWERDB < LIMITMIN
4 = UPPERDB < LOWERDB
5 = Illegal format specified
for UPPERDB or LOWERDB
6 = ASCII value cannot be
translated to numeric
7 = Duplicate limit definition
for this variable
>7 = Other equipment-specific
error
8-63 Reserved
S2F46
SEMI E5-1104 © SEMI 1982, 2004 22
Name Format Description Values Where Used
LIMITID 10 The identifier of a specific
limit in the set of limits (as
defined by UPPERDB and
LOWERDB) for a variable to
which the corresponding limit
attributes refer, 1 byte.
S2F45, F46,
F48
LIMITMAX 11, 20,
3(), 4(),
5()
The maximum allowed value
for the limit values of a
specific variable. The
equipment manufacturer
should specify this value,
which would typically
coincide with the maximum
value of the variable being
monitored. The format must
match that of the referenced
variable.
S2F48
LIMITMIN 11, 20,
3(), 4(),
5()
The minimum allowed value
for the limit values of a
specific variable. The
equipment manufacturer
should specify this value,
which would typically
coincide with the minimum
value of the variable being
monitored. The format must
match that of the referenced
variable.
S2F48
LINKID 54 Used to link a completion
message with a request that
an operation be performed.
LINKID is set to the value of
RMOPID in the initial
request except for the last
completion message to be
sent, where it is set to zero.
S6F25;
S14F20, F21;
S15F22, F30
LLIM 3(), 4(),
5()
Lower limit for numeric
value
S7F22
LOC 10 Machine material location
code, 1 byte
S2F27;
S3F2
LOCID 20 The logical identifier of a
material location.
S3F29, F31
LOWERDB 11, 20,
3(), 4(),
5()
A variable limit attribute
which defines the lower
boundary of the deadband of
a limit. The value applies to
a single limit (LIMITID) for a
specified VID. Thus,
UPPERDB and LOWERDB
as a pair define a limit.
S2F45, F48
SEMI E5-1104 © SEMI 1982, 2004 23
Name Format Description Values Where Used
LRACK 10 Link Report Acknowledge
Code, 1 byte
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one CEID
link already defined
4 = Denied. At least one CEID
does not exist
5 = Denied. At least one RPTID
does not exist
>5 = Other errors
6-63 Reserved
S2F36
LVACK 10 Variable limit definition
acknowledge code, 1 byte.
Defines the error with the
limit attributes for the
referenceVID.
1 = Variable does not exist
2 = Variable has no limits
capability
3 = Variable repeated in
message
4 = Limit value error as
described in LIMITACK
5-63 Reserved
S2F46
MAPER 10 Map Error
0 = ID not found
1 = Invalid Data
2 = Format Error
>2 = Invalid error
3-63 Reserved
S12F19
MAPFT 10 Map data format type
0 = Row format
1 = Array format
2 = Coordinate format
>2 = Error
3-63 Reserved
S12F3, F5
MCINDEX 5() Identifier used to link a
handoff command message
with its eventual completion
message. Corresponding
messages carry the same
value for this data item.
S4F31, F33
MDACK 10 Map data acknowledge
0 = Map received
1 = Format error
2 = No ID match
3 = Abort/discard map
>3 = Error
4-63 Reserved
S12F8, F10,
F12
MDLN 20 Equipment Model Type, 6
bytes max
Same data as returned by S1,F2
S1F2, F13, F14;
S7F22, F23,
F26, F31, F39,
F43
MEXP 20 Message expected in the form
SxxFyy where x is stream and
y is function
S9F13