SEMI S2-0703a
E
© SEMI 1991, 2004 73
R10-3 Japan
R10-3.1. The Japanese Safety Association published an
English version of the Japanese laser safety standard
based on the IEC 60825 series document. This standard
is Japanese Industrial Standard (JIS) C 6802. The
Japanese version is still the official standard, but the
English version has the warning hazards described with
the Japanese symbols in the images.
R10-3.2. As in the IEC document the manufacturing
requirements are specified in Section 2. There is a
companion document JIS C 6801 that provides the
Glossary of terms and their translations into English.
R10-3.3. The JIS documents can be obtained through
the Japanese Safety Association.
R10-3.4. Japanese Standards Association
1-24 Akasaka 4
Minato-Ku
JP-107 TOKYO
TP: +81 3 3583 80 03
TF: +81 3 3586 20 29
http://www.jsa.or.jp/eng/catalog/frame.html is
searchable
R10-3.5. Websites:
(In English) http://www.hike.te.chiba-
u.ac.jp/ikeda/JIS/index.html
(In Japanese) http://www.jsa.or.jp
R10-4 Other (e.g., Pacific Rim)
R10-4.1 The manufacturer is responsible to determine
the appropriate standard to use in other countries.
R10-4.2 In the absence of any specific standard for a
country, the IEC 60825-1 document should be used as
the guide for compliance
R10-4.3 In many countries, prefectures, states, or
provinces, local laser safety regulations exist. Much of
this regulation is aimed at the user, but may include
product performance requirements. The manufacturer
has the responsibility to identify these requirements.
R10-4.4 Addresses of many national standards
organizations are found at:
http://www.iec.ch/cs1sot-e.htm

SEMI S2-0703a
E
© SEMI 1991, 2004 74
RELATED INFORMATION 11
OTHER REQUIREMENTS BY REGION OF USE
NOTICE: This related information is not an official part of SEMI S2 and was derived from practical application by
task force members. This related information was approved for publication by vote of the responsible committee on
October 21, 1999.
R11-1 Japan — Earth Leakage Breaker/Ground
Fault Circuit Interrupter/Ground Fault
Equipment Protection Circuit Interrupter/
Residual Current Devices
R11-1.1 Japanese regulations may require the use of
Ground Fault Circuit Interrupter (GFCI), Ground Fault
Equipment Protection Circuit Interrupter (GFEPCI),
Residual Current Devices (RCD), or Earth Leakage
Breaker (ELB) with the equipment.
EXCEPTION 1: The rating of the equipment is less
than 20 amperes and less than 150 volts rms.
EXCEPTION 2: The equipment is supplied from the
ungrounded secondary of an AC mains isolation
transformer.
R11-1.2 The GFCI, GFEPCI, RCD or ELB, when
required to satisfy Japanese requirements, should have
trip ratings of not greater than 30 mA and 0.1 second.
EXCEPTION 1: If there is no accessible live circuit
during maintenance tasks, trip ratings of up to 300 mA
are acceptable.
EXCEPTION 2: If the equipment satisfies Exception 1
and the earth impedance is less than 50 ohms, a GFCI,
GFEPCI, RCD or ELB of 500 mA maximum is
acceptable.
EXCEPTION 3: If the equipment is connected to a
source of supply that is provided with a GFCI,
GFEPCI, RCD or ELB, an additional GFCI, GFEPCI,
RCD or ELB is not required for the equipment.
R11-2 USA
R11-2.1 Nameplates — In addition to the nameplate
requirement noted in the Electrical section of S2,
equipment evaluated as “Industrial Machinery” per
NFPA 79 and intended for use in the United States may
be required to display additional nameplate
information, such as ampere rating of the largest motor
or load, short circuit interrupting capacity of the
machine overcurrent protective device where furnished
as part of the equipment, and the electrical diagram
number(s) or the number of the index to the electrical
diagrams. Furthermore, where overcurrent protection is
provided, the equipment must be marked “overcurrent
protection provided at machine supply terminals.”
R11-2.1 Hazard Communication — Federal
government OSHA regulations, found in 29 CFR
1910.1200, establish various requirements for labeling
of containers of hazardous chemicals and providing
Material Safety Data Sheets.
R11-3 Europe
R11-3.1 Nameplates — In addition to the nameplate
requirement noted in the Electrical section of S2,
equipment evaluated as “Industrial Machinery” per IEC
60204-1 (EN 60204-1) and intended for use in Europe
may be required to display additional nameplate
information, such as: certification mark, where
required; current rating of the largest motor or load;
short-circuit interrupting capacity of the machine
overcurrent protective device, where furnished as part
of the equipment; and the electrical diagram number(s)
or the number of the index to the electrical drawings.
R11-3.1.1 Where only a single motor controller is
used, this information may instead be provided on the
machine nameplate where it is plainly visible.
R11-3.1.2 The full-load current shown on the
nameplate shall be not less than the combined full-load
currents for all motors and other equipment that can be
in operation at the same time under normal conditions
of use. Where unusual loads or duty cycles require
oversized conductors, the required capacity shall be
included in the full-load current specified on the
nameplate.
R11-3.2 European Union requires compliance to CE
marking.
R11-4 Worldwide — Hazard Alert Labels
R11-4.1 USA — Labels intended for use in the USA
should conform to ANSI Z535.4.
R11-4.2 Other Countries — Labels intended for use in
countries other than the USA should conform to ISO
3864.

SEMI S2-0703a
E
© SEMI 1991, 2004 75
RELATED INFORMATION 12
LIGHT TOWER COLOR AND AUDIBLE ALERT CODES
NOTICE: This related information is not an official part of SEMI S2 and was derived from practical application by
task force members. This related information was approved for publication by vote of the responsible committee on
October 21, 1999.
R12-1 Colors for Light Towers
R12-1.1 Where used for safety, a light tower should have the following characteristics:
Table R12-1 Light Tower Color Code
Color Explanation Examples
Red Hazardous, dangerous or abnormal
condition requiring immediate
attention
Pressure/temperature out of safe limits;
Voltage drop; Breakdown
Overtravel of a stop position
Indication that a protective device has stopped the machine, e.g.,
overload
Yellow Abnormal, caution/marginal condition;
Change or impending change of
critical condition requiring monitoring
and/or intervention (e.g., by re-
establishing the intended function)
Pressure/temperature exceeding normal limits
Tripping of protective device Automatic cycle or motors running; some
value (pressure, temperature) is approaching its permissible limit.
Ground fault indication. Overload that is permitted for a limited time.
Green Normal condition; machine ready Pressure/temperature within normal limits
Indication of safe condition or authorization to proceed. Machine ready
for operation with all conditions normal or cycle complete and machine
ready to be restarted.
R12-2 Audible Alert (Buzzer) Code
R12-2.1 Where used for safety, audible alert (buzzer) for the light tower should have the following characteristics:
Table R12-2 Light Tower Buzzer Code
Color Audible Alert (Buzzer)
Red Continuous
Yellow Intermittent
Green Intermittent/no sound (selectable)