SEMI P21-92 © SEMI 1992, 2003 1 SEMI P21-92 (Reapproved 0703) GUIDELINES FOR PRECISION AND ACCURACY EXPRESSION FOR MASK WRITING EQUIPMENT This guideline was technically approved by the Gl obal Micropatterning Co mmittee …

100%1 / 7923
SEMI P20-0703 © SEMI 1992, 2003 4
NOTICE: SEMI makes no warranties or
representations as to the suitability of the standards set
forth herein for any particular application. The
determination of the suitability of the standard is solely
the responsibility of the user. Users are cautioned to
refer to manufacturer’s instructions, product labels,
product data sheets, and other relevant literature
respecting any materials mentioned herein. These
standards are subject to change without notice.
The user’s attention is called to the possibility that
compliance with this standard may require use of
copyrighted material or of an invention covered by
patent rights. By publication of this standard, SEMI
takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any
item mentioned in this standard. Users of this standard
are expressly advised that determination of any such
patent rights or copyrights, and the risk of infringement
of such rights, are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.
SEMI P21-92 © SEMI 1992, 2003 1
SEMI P21-92 (Reapproved 0703)
GUIDELINES FOR PRECISION AND ACCURACY EXPRESSION FOR
MASK WRITING EQUIPMENT
This guideline was technically approved by the Global Micropatterning Committee and is the direct
responsibility of the Japanese Micropatterning Committee. Current edition approved by the Japanese
Regional Standards Committee on April 28, 2003. Initially available at www.semi.org June 2003; to be
published July 2003. Originally published in 1992.
1 Purpose
1.1 This guideline describes general requirements
concerning precision and accuracy expression of mask
writing equipment. Writing accuracy of the mask
writing equipment is evaluated by measuring a written
mask and is affected greatly by process conditions to be
carried out. Therefore, the writing conditions are to be
agreed upon by the user and supplier.
2 Scope
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Precision and Accuracy Expression Items,
Definitions, Measurement, and Requirements
3.1 Minimum Pattern
3.1.1 Definition
The minimum line and space pattern and minimum
pattern which is possible to be separated.
3.1.2 Expression
SEM photograph
3.1.3 Measurement
SEM photograph of the resist pattern or the chrome
pattern.
3.2 Pattern Dimension Precision and Accuracy
3.2.1 Definition
Critical Dimension (CD) variation and deviation of
written pattern from designed value.
3.2.2 Expression
Deviation of measured mean value to design value
(l:µm) and variations (3 σ:µm).
Measured area and number of sampling point
should be clearly described.
3.2.3 Measurement
Optical CD measurement
Electron beam CD measurement
CD measurement done by self-diagnostic feature of
writing equipment.
3.2.4 Requirement
Width of a long line pattern in X and Y direction
should be measured.
Pattern types are isolated pattern; 1:1 line and
space pattern or 1:2 line and space pattern.
The line width to be measured is not specified, but
at least three different line widths should be
measured.
Examples of patterns are shown in Figures 1 and 2.
3.3 Overlay Accuracy
3.3.1 Definition
Relative deviation of pattern position between two
masks.
3.3.2 Expression
3σ:µm (X and Y direction separately)
Measured area and number of sampling points
should be clearly described.
3.3.3 Measurement
Optical coordinates measurement
Electron beam coordinates measurement
Coordinates measurement done by self-diagnostic
feature of writing equipment.
3.3.4 Requirement
The pattern should be cross or L mark. Uniform
rotation error in measurement should be subtracted
from the measurement result.
Overlay accuracy between different cassette should
be clearly described. An example of a pattern is
shown in Figure 3.
SEMI P21-92 © SEMI 1992, 2003 2
3.4 Pattern Stitching Accuracy
3.4.1 Definition
Position errors at the stitching boundary of writing
fields, stripes, and shots.
3.4.2 Expression
|average value| 1 + 3 σµm (X and Y direction
separately) measured area and number of sampling
points should be clearly described.
3.4.3 Measurement
Optical coordinates measurement
Electron beam coordinate measurement
Coordinates measurement done by self-diagnostic
feature of writing equipment.
Vernier measurement
Boundary measurement by SEM image
3.4.4 Requirement
The pattern should be cross or L marks in both
sides adjacent to the stitching boundary for
coordinate measurement.
When the optical microscope is used for
measurement, the vernier pattern should be used.
4 Notice
4.1 The following subjects should be agreed upon
beforehand between users and makers in order to
evaluate the above-mentioned writing precision and
accuracy item.
4.1.1 Process Requirements
Resist Materials
Coating Condition
Development Condition
Process Sequence
Mask Substrate and Chrome Thin Film Materials
4.1.2 Test Pattern
4.1.3 Measurement Procedure
5 Others
5.1 The following items are not specified in these
guidelines, still it is preferable that these items are
agreed upon beforehand between user and supplier.
5.1.1 Pattern coordinates
5.1.2 Pattern position accuracy
5.1.3 Long-term stability of accuracy
5.1.4 Particles